Two-sewing-ring technique for a self-assembled aortic valve conduit to the annulus

Author(s):  
Laichun Song ◽  
Liang Tao
2018 ◽  
Vol 156 (1) ◽  
pp. 89-95.e2 ◽  
Author(s):  
Paul P. Urbanski ◽  
Fitsum Lakew ◽  
Witold Dinstak ◽  
Nicolas Heinz ◽  
Michael Zacher ◽  
...  

2020 ◽  
Vol 25 (6) ◽  
pp. 2055-2059
Author(s):  
ADRIAN TULIN ◽  
◽  
OVIDIU STIRU ◽  
MIRUNA LUANA MIULESCU ◽  
LAURA RADUCU ◽  
...  

This report concerns a 73-year-old woman who presented with asymptomatic aortic root an-eurysm with severe aortic regurgitation. The purpose of this article is to present our first successful case for emergency aortic root replacement (Bentall operation) that involves annular implantation of a pericardial valved conduit (Bioconduit TM, Biointegral Surgical, Inc., Ontario, Canada) and to discuss some essential technical clue issues related to this approach.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Nicholas Y Tan ◽  
Alex D Tarabochia ◽  
Omar M Abu Saleh ◽  
Courtney Bennett

Introduction: Mycobacterium Chimaera (MC) infections following cardiovascular surgery are challenging to diagnose given their insidious presentation. We therefore reviewed the various imaging modalities used to diagnose these infections at Mayo Clinic. Methods: Cases from 01/01/2010-06/01/2020 were identified using electronic medical records. Demographics and clinical history were collected. Imaging studies, including transthoracic echocardiogram (TTE), transesophageal echocardiogram (TEE), positron emission tomography / computed tomography (PET/CT), cardiac CT (CCT), and cardiac magnetic resonance (CMR) were reviewed. Results: A total of 7 patients (85.7% male) were found. 6 underwent aortic valve replacement and 1 received an aortic composite valve conduit. Surgical dates ranged from 01/2010-12/2018. Mean age at presentation was 63.3 years. Mean time from surgery to symptom onset was 28.0 months. All patients underwent TTE and TEE; prosthetic valve endocarditis was identified in 6 cases between both, while CMR established the diagnosis in 1 case. TTE showed prosthetic valve obstruction in 2 cases and an anterior pseudoaneurysm in 1 case. TEE findings included thickened prosthesis and/or vegetations (n=5), thickened posterior root (n=4), and root abscess (n=3). Among the 3 patients who underwent PET/CT, 2 demonstrated increased fluorodeoxyglucose (FDG) uptake around the aortic prosthesis; in addition, 1 had elevated FDG uptake in the myocardium suggesting myocarditis. 1 patient did not have aortic prosthesis FDG uptake. In the 2 patients who had CCT, 1 showed a pseudoaneurysm that prompted suspicion for endocarditis, and the other revealed a fluid collection adjacent to the aortic valve conduit. 2 patients underwent CMR; 1 had aortic prosthesis thickening and patchy areas of myocardial delayed enhancement suspicious for myocarditis, whereas the other showed vegetation and an aortic root abscess. Conclusion: TTE plus TEE successfully identified MC prosthetic valve endocarditis in most cases with TEE having higher specificity. Advanced imaging techniques are helpful to support the diagnosis and assess for myocardial and/or aortic involvement. Combining these modalities is therefore crucial in unveiling this elusive organism.


Author(s):  
C R Gentle ◽  
S E Leefe

Pulsatile in vitro flow tests are reported on a Björk-Shiley conduit disc valve and a prototype ball valve conduit, both used as replacements for the aortic valve and ascending aorta. Comparison is made with a model of the aortic stenosis which the conduits would be used to replace. It is found that although the ball valve is considerably better than the disc valve, in terms of pressure drop and power loss for a given cardiac output, both prostheses offer large improvements on the stenotic situation.