scholarly journals Frequency weighted H2 optimization of multi-mode input shaper

Automatica ◽  
2020 ◽  
Vol 121 ◽  
pp. 109202
Author(s):  
Martin Goubej ◽  
Tomáš Vyhlídal ◽  
Miloš Schlegel
2011 ◽  
Vol 2-3 ◽  
pp. 372-377 ◽  
Author(s):  
Yan Yan Han ◽  
Bing Li ◽  
Yu Lan Wei ◽  
Shou Xin Zhu ◽  
Ying Jun Dai

The classic multi-mode negative impulses input shapers can suppress the residual vibration of the multi-mode system effectively. But when these several frequencies bandwidths and amplitudes of vibration modes are greatly different, the time delay and the suppression performances of input shapers are decreased. However, the hybrid multi-mode negative impulses input shapers can overcome the disadvantage. The hybrid double-mode negative impulses input shapers of a 3-DOF parallel manipulator and are constructed and compared with the classic multi-mode negative impulses input shapers. And the numerical simulations are shown out, for different frequencies bandwidths and amplitudes of vibration, and the hybrid multi-mode negative impulses input shapers can increase the total suppression performance of input shaper.


Author(s):  
E. D. Salmon ◽  
J. C. Waters ◽  
C. Waterman-Storer

We have developed a multi-mode digital imaging system which acquires images with a cooled CCD camera (Figure 1). A multiple band pass dichromatic mirror and robotically controlled filter wheels provide wavelength selection for epi-fluorescence. Shutters select illumination either by epi-fluorescence or by transmitted light for phase contrast or DIC. Many of our experiments involve investigations of spindle assembly dynamics and chromosome movements in live cells or unfixed reconstituted preparations in vitro in which photodamage and phototoxicity are major concerns. As a consequence, a major factor in the design was optical efficiency: achieving the highest image quality with the least number of illumination photons. This principle applies to both epi-fluorescence and transmitted light imaging modes. In living cells and extracts, microtubules are visualized using X-rhodamine labeled tubulin. Photoactivation of C2CF-fluorescein labeled tubulin is used to locally mark microtubules in studies of microtubule dynamics and translocation. Chromosomes are labeled with DAPI or Hoechst DNA intercalating dyes.


2009 ◽  
Vol E92-B (12) ◽  
pp. 3717-3725
Author(s):  
Thomas HUNZIKER ◽  
Ziyang JU ◽  
Dirk DAHLHAUS

2014 ◽  
Vol E97.C (7) ◽  
pp. 781-786 ◽  
Author(s):  
Mohammad NASIR UDDIN ◽  
Takaaki KIZU ◽  
Yasuhiro HINOKUMA ◽  
Kazuhiro TANABE ◽  
Akio TAJIMA ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document