Obesity as a Risk Factor for Consideration for Left Ventricular Assist Devices

2015 ◽  
Vol 21 (10) ◽  
pp. 800-805 ◽  
Author(s):  
Burhan Mohamedali ◽  
Gardner Yost ◽  
Geetha Bhat
2021 ◽  
Vol 8 ◽  
Author(s):  
Melanie Kranzl ◽  
Martin Stoiber ◽  
Anne-Kristin Schaefer ◽  
Julia Riebandt ◽  
Dominik Wiedemann ◽  
...  

Background: Risk factors for driveline infection (DLI) in patients with left ventricular assist devices are multifactorial. The aim of this study was to analyze the correlation between mechanical driveline features and DLI occurrence.Methods: A meta-analysis was conducted that included studies reporting DLI rates at 6 months after implantation of any of three contemporary devices (HVAD with Pellethane or Carbothane driveline, HeartMate II, and HeartMate 3). Further, outer driveline diameter measurements and ex-vivo experimental three-point bending and torsion tests were performed to compare the stiffness of the four different driveline types.Results: 21 studies with 5,393 patients were included in the meta-analysis. The mean weighted DLI rates ranged from 7.2% (HeartMate II) to 11.9% (HeartMate 3). The HeartMate II driveline had a significantly lower maximal bending force (Loadmax) (4.52 ± 0.19 N) compared to the Carbothane HVAD (8.50 ± 0.08 N), the HeartMate 3 (11.08 ± 0.3 N), and the Pellethane HVAD driveline (15.55 ± 0.14 N) (p < 0.001). The maximal torque (Torquemax) of the HeartMate II [41.44 (12.61) mNm] and the Carbothane HVAD driveline [46.06 (3.78) mNm] were significantly lower than Torquemax of the Pellethane HVAD [46.06 (3.78) mNm] and the HeartMate 3 [95.63 (26.60) mNm] driveline (p < 0.001). The driveline of the HeartMate 3 had the largest outer diameter [6.60 (0.58) mm]. A relationship between the mean weighted DLI rate and mechanical driveline features (Torquemax) was found, as the the HeartMate II driveline had the lowest Torquemax and lowest DLI rate, whereas the HeartMate 3 driveline had the highest Torquemax and highest DLI rate.Conclusions: Device-specific mechanical driveline features are an additional modifiable risk factor for DLI and may influence clinical outcomes of LVAD patients.


2010 ◽  
Vol 5 (1) ◽  
pp. 16
Author(s):  
Aman Ali ◽  
Timothy A Sanborn ◽  
◽  

Among patients with acute myocardial infarction (AMI), those in cardiogenic shock have the highest mortality rate. Early revascularisation with primary percutaneous intervention or coronary artery bypass surgery has decreased the mortality rate of patients in cardiogenic shock, but it remains high. The conventional treatment of haemodynamic instability has been the use of the intra-aortic balloon pump (IABP); however, the IABP may not give adequate support to patients with severe left ventricular dysfunction. Recent advances in percutaneous left ventricular assist devices, specifically the TandemHeart and Impella LP 2.5, have shown improved haemodynamic support compared with the IABP. This article provides an overview of the use of percutaneous left ventricular assist devices to treat patients presenting with cardiogenic shock after acute MI.


Sign in / Sign up

Export Citation Format

Share Document