Assessment of the Annual Eye Lens Dose for Cardiologists During Interventional Procedures Using Anthropomorphic Phantoms and mEyeDose_X Tool

2020 ◽  
Vol 21 (4) ◽  
pp. 527-531
Author(s):  
Mohammed Khalil Saeed
2014 ◽  
Vol 163 (2) ◽  
pp. 181-187 ◽  
Author(s):  
Y. Kong ◽  
L. Struelens ◽  
F. Vanhavere ◽  
C. S. Vargas ◽  
W. Schoonjans ◽  
...  

2019 ◽  
Vol 68 ◽  
pp. 47-51 ◽  
Author(s):  
Jeannie Hsiu Ding Wong ◽  
Lydia Esther Andrew Anem ◽  
Suzet Tan ◽  
Sock Keow Tan ◽  
Kwan Hoong Ng

2019 ◽  
Vol 185 (2) ◽  
pp. 135-142 ◽  
Author(s):  
Predrag Božović ◽  
Olivera Ciraj-Bjelac ◽  
Jelena Stanković Petrović

Abstract Medical personnel performing interventional procedures in cardiology and radiology is considered to be a professional group exposed to high doses of ionizing radiation. Reduction of the eye lens dose limit made its assessment in the interventional procedures one of the most challenging topics. The objective of this work is to assess eye lens doses based on the whole-body doses using methods of computational dosimetry. Assessment included different C-arm orientations (PA, LAO and RAO), tube voltages (80 –110 kV) and efficiency of different combinations of protective equipment used in interventional procedures. Center position at the height of the thyroid gives best estimate of eye lens dose, with spreads of 11% (13%), 13% (17%) and 14% (13%) for the left (right) eye lens. The conversion factors of 1.03 (0.83), 1.28 (1.06) and 1.36 (1.06) to convert whole body to eye lens dose were derived for positions of first operator, nurse and radiographer, respectively. The eye lens dose reduction factors for different combinations of applied protective equipment are 178, 5 and 6, respectively.


Author(s):  
Jacob Collins ◽  
Sheng-Hsuan Sun ◽  
Chao Guo ◽  
Alexander R. Podgorsak ◽  
Stephen Rudin ◽  
...  

2019 ◽  
Vol 60 ◽  
pp. 127-131 ◽  
Author(s):  
Margherita Betti ◽  
Lorenzo Nicola Mazzoni ◽  
Giacomo Belli ◽  
Luca Bernardi ◽  
Sara Bicchi ◽  
...  

2021 ◽  
Vol 94 (1126) ◽  
pp. 20210436 ◽  
Author(s):  
Beth A. Schueler ◽  
Kenneth A Fetterly

Data suggest that radiation-induced cataracts may form without a threshold and at low-radiation doses. Staff involved in interventional radiology and cardiology fluoroscopy-guided procedures have the potential to be exposed to radiation levels that may lead to eye lens injury and the occurrence of opacifications have been reported. Estimates of lens dose for various fluoroscopy procedures and predicted annual dosages have been provided in numerous publications. Available tools for eye lens radiation protection include accessory shields, drapes and glasses. While some tools are valuable, others provide limited protection to the eye. Reducing patient radiation dose will also reduce occupational exposure. Significant variability in reported dose measurements indicate dose levels are highly dependent on individual actions and exposure reduction is possible. Further follow-up studies of staff lens opacification are recommended along with eye lens dose measurements under current clinical practice conditions.


Sign in / Sign up

Export Citation Format

Share Document