The clinical and diagnostic performance characteristics of the high sensitivity Abbott cardiac troponin I assay

2015 ◽  
Vol 48 (4-5) ◽  
pp. 275-281 ◽  
Author(s):  
P.O. Collinson ◽  
D. Gaze ◽  
S. Goodacre
2017 ◽  
Vol 63 (10) ◽  
pp. 1594-1604 ◽  
Author(s):  
Yader Sandoval ◽  
Stephen W Smith ◽  
Sarah E Thordsen ◽  
Charles A Bruen ◽  
Michelle D Carlson ◽  
...  

Abstract BACKGROUND We examined the diagnostic performance of high-sensitivity cardiac troponin I (hs-cTnI) vs contemporary cTnI with use of the 99th percentile alone and with a normal electrocardiogram (ECG) to rule out acute myocardial infarction (MI) and serial changes (deltas) to rule in MI. METHODS We included consecutive patients presenting to a US emergency department with serial cTnI onclinical indication. Diagnostic performance for acute MI, including MI subtypes, and 30-day outcomes were examined. RESULTS Among 1631 patients, MI was diagnosed in 12.9% using the contemporary cTnI assay and in 10.4% using the hs-cTnI assay. For ruling out MI, contemporary cTnI ≤99th percentile at 0, 3, and 6 h and a normal ECG had a negative predictive value (NPV) of 99.5% (95% CI, 98.6–100) and a sensitivity of 99.1% (95% CI, 97.4–100) for diagnostic and safety outcomes. Serial hs-cTnI measurements ≤99th percentile at 0 and 3 h and a normal ECG had an NPV and sensitivity of 100% (95% CI, 100–100) for diagnostic and safety outcomes. For ruling in MI, contemporary cTnI measurements had specificities of 84.4% (95% CI, 82.5–86.3) at presentation and 78.7% (95% CI, 75.4–82.0) with serial testing at 0, 3, and 6 h, improving to 89.2% (95% CI, 87.1–91.3) by using serial cTnI changes (delta, 0 and 6 h) >150%. hs-cTnI had specificities of 86.9% (95% CI, 85.1–88.6) at presentation and 85.7% (95% CI, 83.5–87.9) with serial testing at 0 and 3 h, improving to 89.3% (95% CI, 87.3–91.2) using a delta hs-cTnI (0 and 3 h) >5 ng/L. CONCLUSIONS hs-cTnI and contemporary cTnI assays are excellent in ruling out MI following recommendations predicated on serial testing and the 99th percentile with a normal ECG. For ruling in MI, deltas improve the specificity. ClinicalTrials.gov Identifier: NCT02060760


Author(s):  
Peter A. Kavsak ◽  
Tara Edge ◽  
Chantele Roy ◽  
Paul Malinowski ◽  
Karen Bamford ◽  
...  

AbstractObjectivesTo analytically evaluate Ortho Clinical Diagnostics VITROS high-sensitivity cardiac troponin I (hs-cTnI) assay in specific matrices with comparison to other hs-cTn assays.MethodsThe limit of detection (LoD), imprecision, interference and stability testing for both serum and lithium heparin (Li-Hep) plasma for the VITROS hs-cTnI assay was determined. We performed Passing-Bablok regression analyses between sample types for the VITROS hs-cTnI assay and compared them to the Abbott ARCHITECT, Beckman Access and the Siemens ADVIA Centaur hs-cTnI assays. We also performed Receiver-operating characteristic curve analyses with the area under the curve (AUC) determined in an emergency department (ED)-study population (n=131) for myocardial infarction (MI).ResultsThe VITROS hs-cTnI LoD was 0.73 ng/L (serum) and 1.4 ng/L (Li-Hep). Stability up to five freeze-thaws was observed for the Ortho hs-cTnI assay, with the analyte stability at room temperature in serum superior to Li-Hep with gross hemolysis also affecting Li-Hep plasma hs-cTnI results. Comparison of Li-Hep to serum concentrations (n=202), yielded proportionally lower concentrations in plasma with the VITROS hs-cTnI assay (slope=0.85; 95% confidence interval [CI]:0.83–0.88). In serum, the VITROS hs-cTnI concentrations were proportionally lower compared to other hs-cTnI assays, with similar slopes observed between assays in samples frozen <−70 °C for 17 years (ED-study) or in 2020. In the ED-study, the VITROS hs-cTnI assay had an AUC of 0.974 (95%CI:0.929–0.994) for MI, similar to the AUCs of other hs-cTn assays.ConclusionsLack of standardization of hs-cTnI assays across manufacturers is evident. The VITROS hs-cTnI assay yields lower concentrations compared to other hs-cTnI assays. Important differences exist between Li-Hep plasma and serum, with evidence of stability and excellent clinical performance comparable to other hs-cTn assays.


Author(s):  
Peter A. Kavsak ◽  
Shawn Mondoux ◽  
Andrew Worster ◽  
Janet Martin ◽  
Vikas Tandon ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document