Does Dose to an Oral Mucosa Organ at Risk Predict the Duration of Grade 3 Mucositis after Intensity-modulated Radiotherapy for Oropharyngeal Cancer?

2016 ◽  
Vol 28 (12) ◽  
pp. e216-e219 ◽  
Author(s):  
S. Yahya ◽  
H. Benghiat ◽  
P. Nightingale ◽  
M. Tiffany ◽  
P. Sanghera ◽  
...  
2006 ◽  
Vol 13 (3) ◽  
pp. 108-115 ◽  
Author(s):  
O. Ballivy ◽  
W. Parker ◽  
T. Vuong ◽  
G. Shenouda ◽  
H. Patrocinio

We assessed the effect of geometric uncertainties on target coverage and on dose to the organs at risk (OARS) during intensity-modulated radiotherapy (IMRT) for head-and-neck cancer, and we estimated the required margins for the planning target volume (PTV) and the planning organ-at-risk volume (PRV). For eight headand- neck cancer patients, we generated IMRT plans with localization uncertainty margins of 0 mm, 2.5 mm, and 5.0 mm. The beam intensities were then applied on repeat computed tomography (CT) scans obtained weekly during treatment, and dose distributions were recalculated. The dose–volume histogram analysis for the repeat CT scans showed that target coverage was adequate (V100 ≥ 95%) for only 12.5% of the gross tumour volumes, 54.3% of the upper-neck clinical target volumes (CTVS), and 27.4% of the lower-neck CTVS when no margins were added for PTV. The use of 2.5-mm and 5.0-mm margins significantly improved target coverage, but the mean dose to the contralateral parotid increased from 25.9 Gy to 29.2 Gy. Maximum dose to the spinal cord was above limit in 57.7%, 34.6%, and 15.4% of cases when 0-mm, 2.5-mm, and 5.0-mm margins (respectively) were used for PRV. Significant deviations from the prescribed dose can occur during IMRT treatment delivery for headand- neck cancer. The use of 2.5-mm to 5.0-mm margins for PTV and PRV greatly reduces the risk of underdosing targets and of overdosing the spinal cord.


PLoS ONE ◽  
2015 ◽  
Vol 10 (3) ◽  
pp. e0121679 ◽  
Author(s):  
Jia-Yang Lu ◽  
Michael Lok-Man Cheung ◽  
Bao-Tian Huang ◽  
Li-Li Wu ◽  
Wen-Jia Xie ◽  
...  

2007 ◽  
Vol 107 (5) ◽  
pp. 917-926 ◽  
Author(s):  
Carys Thomas ◽  
Salvatore Di Maio ◽  
Roy Ma ◽  
Emily Vollans ◽  
Christina Chu ◽  
...  

Object The goal in this study was to evaluate hearing preservation rates and to determine prognostic factors for this outcome following fractionated stereotactic radiotherapy (FSRT) of vestibular schwannoma. Methods Thirty-four consecutive patients with serviceable hearing who received FSRT between May 1998 and December 2003 were identified. Clinical and audiometry data were collected prospectively. The prescription dose was 45 Gy in 25 fractions prescribed to the 90% isodose line. The median follow-up duration was 36.5 months (range 12–85 months). The actuarial 2- and 4-year local control rates were 100 and 95.7%, respectively. Permanent trigeminal and facial nerve complications were 0 and 6%, respectively. The actuarial 2- and 3-year serviceable hearing preservation rates were both 63%. The median loss in speech reception threshold was 15 dB (range −10 to 65 dB). The radiotherapy dose to the cochlea was the only significant prognostic factor for hearing deterioration. Radiotherapy dose to the cochlear nucleus, patient age, sex, pre-FSRT hearing grade, tumor volume, and intracanalicular tumor volume failed to show any significance as prognostic factors. Results Five cases were replanned with four different radiotherapy techniques (namely arcs, dynamic arcs, static conformal fields, and intensity-modulated radiotherapy), with the cochlea defined as an organ at risk. In all cases, replanning resulted in statistically significant reduction in radiation to the cochlea (p = 0.001); however, no single replanning technique was found to be superior. Conclusions The radiation dose to the cochlea is strongly predictive for subsequent hearing deterioration. It is essential for the cochlea to be outlined as an organ at risk, and for radiation techniques to be optimized, to improve long-term hearing preservation.


Sign in / Sign up

Export Citation Format

Share Document