Relationship Between Pelvic Organ-at-Risk Dose and Clinical Target Volume in Postprostatectomy Patients Receiving Intensity-Modulated Radiotherapy

2012 ◽  
Vol 82 (5) ◽  
pp. 1897-1902 ◽  
Author(s):  
Sinisa Stanic ◽  
Mathew Mathai ◽  
Jing Cui ◽  
James A. Purdy ◽  
Richard K. Valicenti
2006 ◽  
Vol 13 (3) ◽  
pp. 108-115 ◽  
Author(s):  
O. Ballivy ◽  
W. Parker ◽  
T. Vuong ◽  
G. Shenouda ◽  
H. Patrocinio

We assessed the effect of geometric uncertainties on target coverage and on dose to the organs at risk (OARS) during intensity-modulated radiotherapy (IMRT) for head-and-neck cancer, and we estimated the required margins for the planning target volume (PTV) and the planning organ-at-risk volume (PRV). For eight headand- neck cancer patients, we generated IMRT plans with localization uncertainty margins of 0 mm, 2.5 mm, and 5.0 mm. The beam intensities were then applied on repeat computed tomography (CT) scans obtained weekly during treatment, and dose distributions were recalculated. The dose–volume histogram analysis for the repeat CT scans showed that target coverage was adequate (V100 ≥ 95%) for only 12.5% of the gross tumour volumes, 54.3% of the upper-neck clinical target volumes (CTVS), and 27.4% of the lower-neck CTVS when no margins were added for PTV. The use of 2.5-mm and 5.0-mm margins significantly improved target coverage, but the mean dose to the contralateral parotid increased from 25.9 Gy to 29.2 Gy. Maximum dose to the spinal cord was above limit in 57.7%, 34.6%, and 15.4% of cases when 0-mm, 2.5-mm, and 5.0-mm margins (respectively) were used for PRV. Significant deviations from the prescribed dose can occur during IMRT treatment delivery for headand- neck cancer. The use of 2.5-mm to 5.0-mm margins for PTV and PRV greatly reduces the risk of underdosing targets and of overdosing the spinal cord.


2010 ◽  
Vol 4 (1) ◽  
pp. 131-139
Author(s):  
Thanarpan Peerawong ◽  
Chonlakiet Khorprasert ◽  
Sivalee Suriyapee ◽  
Taweap Sanghangthum ◽  
Isra Israngkul Na Ayuthaya ◽  
...  

Abstract Background: Radiotherapy in cholangiocrcinoma has to overcome organ tolerance of the upper abdomen. Hi-technology radiotherapy may improve conformity and reduce dose to those organ. Objective: Quantitatively compare the dosimetry of conformal dynamic arc radiotherapy (CD-arcRT) and intensity modulated radiotherapy (IMRT) in unresectable cholangiocarcinoma. Material and methods: Eleven cases of unresectable cholangiocarcinoma were re-planned with IMRT and CDarcRT at King Chulalongkhorn Memorial Hospital between 20 September 2004 and 31 December 2005. Both the planning techniques were evaluated using the dose volume histogram of the planning target volume and organ at risk. The conformation number and dose to critical normal structures were used to determine the techniques. Results: IMRT technique was significantly conformed to the planning target volume than CD-arcRT in term of conformation number. For critical structure, IMRT significantly reduced the radiation dose to liver in terms of mean liver dose, V30Gy and V20Gy of the right kidney. Conclusion: The advantage of IMRT was more conformity and reduced dose to critical structure compared with CD-arcRT, but there was no difference between these techniques in terms of V20Gy of left kidney and maximum dose to the spinal cord.


Sign in / Sign up

Export Citation Format

Share Document