Experimental field investigation of impact and blast load resistance of Ultra High Performance Fibre Reinforced Cementitious Composites (UHPFRCCs)

2015 ◽  
Vol 95 ◽  
pp. 566-574 ◽  
Author(s):  
Demetris Nicolaides ◽  
Antonis Kanellopoulos ◽  
Pericles Savva ◽  
Michael Petrou
2015 ◽  
Vol 67 (17) ◽  
pp. 923-937 ◽  
Author(s):  
Anwar Q. Sobia ◽  
Mohd S. Hamidah ◽  
Ibrahim Azmi ◽  
Sahibzada F. A. Rafeeqi

2021 ◽  
Vol 312 ◽  
pp. 125440
Author(s):  
Mylene M. Vieira ◽  
Sergio H.P. Cavalaro ◽  
Antonio Aguado ◽  
Dimas A.S. Rambo ◽  
Renan P. Salvador

2020 ◽  
Vol 11 (4) ◽  
pp. 494-514
Author(s):  
Mohtady Sherif ◽  
Hesham Othman ◽  
Hesham Marzouk ◽  
Hassan Aoude

Ultra-high-performance fibre-reinforced concrete is the latest generation of structural concrete, having outstanding fresh and hardened properties; this includes the ease of placement and consolidation with ultra-high mechanical properties, as well as toughness, volume stability, durability, higher flexural and tensile strength, and ductility. As more research is being focused on it, the material behaviour and characteristics are getting more understood, and the research demand for the special applications of the ultra-high-performance fibre-reinforced concrete is growing higher. One special application that ultra-high-performance fibre-reinforced concrete is thought to have an outstanding performance at is in the field of protective structures, specifically against blast loads. This article presents part of a study that is concerned with the behaviour and response of ultra-high-performance fibre-reinforced concrete wall panels under blast load. Size and shape optimization techniques were combined in this study to optimize the design of a 200-MPa ultra-high-performance fibre-reinforced concrete under blast loads using finite element modelling. This design optimization aims to maximize stiffness and minimize the cost while satisfying both design stresses and construction requirements. The design variable to be optimized for are the thickness ranging from 100 to 300 mm at 25 mm increments, in addition to the reinforcement ratio of 0%, 0.2%, 1% and 3%, and aspect ratio of 1, 1.5 and 2; the boundary condition is four edges fixed and restrained. The numerical simulation has been performed using an explicate finite element software package. The complete behaviour of an ultra-high-performance fibre-reinforced concrete is defined using the concrete damaged plasticity model. The concrete constitutive model has been developed considering the contribution of tensile hardening response, fracture energy and crack-band width approaches to accurately represent the tensile behaviour and guarantee mesh independence of results. The blast load is applied using the Conventional Weapons method of the US Army Corps of Engineers that is readily available in the finite element software. The validity of the numerical model used is verified by comparing numerical results to experimental data.


2017 ◽  
Vol 11 (1) ◽  
pp. 650-663 ◽  
Author(s):  
Mahdi A. Abbaszadeh ◽  
Mohammad K. Sharbatdar ◽  
Ali Kheyroddin

Introduction:Considering the promising results gained from several studies using cementitious composites with strain hardening behaviour (High Performance Fibre Reinforced Cementitious Composites, HPFRCC) for repair and retrofitting concrete flexural members, in this paper the possibility of using HPFRCC for retrofitting two-way RC slabs is investigated.Methods:A total of five two-way slabs were made and tested to failure. Three slabs were retrofitted with a variety of different types of retrofit configurations and two other slabs, having low and conventional reinforcement ratios, were used as control slabs. A novel technique of bonding, designated NSM-HPFRCC, is proposed. Flexural responses of all slabs are evaluated and the bonding behaviour and associated failure modes are investigated.Results and Conclusion:It is shown that the proposed retrofit configurations, especially when accompanied by the NSM-HPFRCC technique, can greatly improve the flexural performance of retrofitted slabs; hence, they can be used successfully to retrieve the flexural reinforcement deficiency of weak slabs.


Sign in / Sign up

Export Citation Format

Share Document