Prospective prediction of the major component of urinary stone composition with dual-source dual-energy CT in vivo

2016 ◽  
Vol 71 (11) ◽  
pp. 1178-1183 ◽  
Author(s):  
G.-M.-Y. Zhang ◽  
H. Sun ◽  
H.-D. Xue ◽  
H. Xiao ◽  
X.-B. Zhang ◽  
...  
2015 ◽  
Vol 205 (6) ◽  
pp. 1203-1207 ◽  
Author(s):  
Xinhui Duan ◽  
Zhoubo Li ◽  
Lifeng Yu ◽  
Shuai Leng ◽  
Ahmed F. Halaweish ◽  
...  

2021 ◽  
pp. 20210084
Author(s):  
Elisabeth Appel ◽  
Christoph Thomas ◽  
Andrea Steuwe ◽  
Benedikt M Schaarschmidt ◽  
Olga R Brook ◽  
...  

Objective: To assess accuracy of dual-energy computed tomography (DECT) to differentiate uric acid from calcium urinary stones in dual-energy split filter vs sequential-spiral vs dual-source acquisition. Methods: Thirty-four urinary stones (volume 89.0 ± 77.4 mm³; 17 calcium stones, 17 uric acid stones) were scanned in a water-filled phantom using a split-filter equipped CT scanner (SOMATOM Definition Edge, Siemens Healthineers, Forchheim, Germany) in split-filter mode at 120kVp and sequential-spiral mode at 80 and 140kVp. Additional DE scans were acquired at 80 and 140kVp (tin filter) with a dual-source CT scanner (SOMATOM Definition FLASH, Siemens Healthineers). Scans were performed with a CTDIvol of 7.3mGy in all protocols. Urinary stone categorization was based on dual energy ratio (DER) using an automated 3D segmentation. As reference standard, infrared spectroscopy was used to determine urinary stone composition. Results: All three DECT techniques significantly differentiated between uric acid and calcium stones by attenuation values and DERs (p < 0.001 for all). Split-filter DECT provided higher DERs for uric acid stones, when compared with dual-source and sequential-spiral DECT, and lower DERs for calcified stones when compared with dual-source DECT (p < 0.001 for both), leading to a decreased accuracy for material differentiation. Conclusion: Split-filter DECT, sequential-spiral DECT and dual-source DECT all allow for the acquisition of DER to classify urinary stones. Advances in knowledge: Split-filter DECT enables the differentiation between uric acid and calcium stones despite decreased spectral separation when compared with dual-source and dual-spiral DECT.


2010 ◽  
Vol 184 (6) ◽  
pp. 2354-2359 ◽  
Author(s):  
D.E. Zilberman ◽  
M.N. Ferrandino ◽  
G.M. Preminger ◽  
E.K. Paulson ◽  
M.E. Lipkin ◽  
...  

2010 ◽  
Vol 195 (5) ◽  
pp. 1164-1174 ◽  
Author(s):  
Andrew N. Primak ◽  
Juan Carlos Ramirez Giraldo ◽  
Christian D. Eusemann ◽  
Bernhard Schmidt ◽  
Birgit Kantor ◽  
...  

2016 ◽  
Vol 207 (2) ◽  
pp. 321-329 ◽  
Author(s):  
Shuai Leng ◽  
Alice Huang ◽  
Juan Montoya Cardona ◽  
Xinhui Duan ◽  
James C. Williams ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document