Short-circuit test of a novel solenoid type high-Tc superconducting fault current limiter

Cryogenics ◽  
2007 ◽  
Vol 47 (7-8) ◽  
pp. 380-386 ◽  
Author(s):  
Chanjoo Lee ◽  
Hyoungku Kang ◽  
Min Cheol Ahn ◽  
Tae Kuk Ko ◽  
Bok-Yeol Seok
2006 ◽  
Vol 16 (2) ◽  
pp. 683-686 ◽  
Author(s):  
T. Yazawa ◽  
Y. Ootani ◽  
M. Sakai ◽  
M. Otsuki ◽  
T. Kuriyama ◽  
...  

1998 ◽  
pp. 1237-1242
Author(s):  
W. Paul ◽  
M. Chen ◽  
M. Lakner ◽  
J. Rhyner ◽  
L. Widenhorn ◽  
...  

2013 ◽  
Vol 389 ◽  
pp. 1089-1095
Author(s):  
Jun Zhen Peng ◽  
Kun Nan Cao ◽  
Da Da Wang ◽  
Meng Song ◽  
Nan Nan Hu ◽  
...  

As one of the most applicable to high-voltage network superconducting fault current limiterSCFCL(saturated core superconducting fault current limiter) ,which use of core saturation properties can be achieved the current-limiting function without delay ,will be the most widely applied in the future,By analyzing the working principle of SCFCL,this paper use of PSCAD and finite element analysis software Ansoft to build the 500kV\/3150A grade SCFCL model and accurate calculation coil self-inductance and mutual inductance, the harmonic of each size and analyzed its Impedance characteristic on the different external parameters,The results show that SCFCL has a excellent performance for high voltage power network short-circuit current limitation, and provides important reference for design.


2001 ◽  
Vol 11 (1) ◽  
pp. 2511-2514 ◽  
Author(s):  
T. Yazawa ◽  
E. Yoneda ◽  
J. Matsuzaki ◽  
M. Shimada ◽  
T. Kuriyama ◽  
...  

2002 ◽  
Vol 12 (1) ◽  
pp. 896-899 ◽  
Author(s):  
Jiacheng Zhang ◽  
Zhiyuan Gao ◽  
Naihao Song ◽  
Huaming Wen ◽  
Liye Xiao ◽  
...  

2020 ◽  
Vol 6 (1) ◽  
pp. 1-4
Author(s):  
Vipul Sharma ◽  
Mrs. Madhu Upadhyay

Introduction of Distributed Energy Sources (DES) is the highest change happening to the distribution network. This paper describes different types of current limiting methods which reduce the magnitude of the fault current. The interconnected distributed energy sources to the conventional grid improves the power generation capacity of the power system but also increases the magnitude of fault current which cannot tolerate by the short-circuit ratings of the circuit breaker, relays, isolator etc. This paper reviews on the innovative electric equipment i.e. Superconducting Fault Current Limiter (SFCL), which reduces fault current magnitude in first cycle of fault current. Keywords: Distributed Energy Sources, Fault current, Superconducting Fault Current Limiter (SFCL), Protection Equipment.


Sign in / Sign up

Export Citation Format

Share Document