scholarly journals Experimental study on heat transfer performance of new gravity heat pipe in geothermal utilization

2019 ◽  
Vol 158 ◽  
pp. 5629-5634
Author(s):  
Pei-pei Zhang ◽  
Jia-ling Zhu ◽  
Ni-ni Chang ◽  
An-da Song ◽  
Yu-jiao Lei ◽  
...  
2012 ◽  
Vol 197 ◽  
pp. 216-220
Author(s):  
Zhong Chao Zhao ◽  
Rui Ye ◽  
Gen Ming Zhou

To solve the cooling problem in modern electronic device, a kind of heat pipe radiator was designed and manufactured in this paper. The heat transfer performance of heat pipe radiator and its relationship with air velocity were investigated by experimental method. The experimental results show that the heat pipe radiator can meet the temperature requirement of electronic device with the power range from 40W to 160W. To keep the operational temperature of electronic device with power of 160W under 75°C,the air velocity should be keep at 1.7m/s. The heat dissipation performance of heat pipe radiator was enhanced with the air velocity increased from 0.2m/s to 1.7m/s.for the electronic equipment with power of 160W.