Using a neural network to predict deviations in mean heart dose during the treatment of left-sided deep inspiration breath hold patients

2019 ◽  
Vol 65 ◽  
pp. 137-142 ◽  
Author(s):  
Ciaran Malone ◽  
Lynda Fennell ◽  
Tracy Folliard ◽  
Colin Kelly
2017 ◽  
Vol 23 (4) ◽  
pp. 109-114 ◽  
Author(s):  
Karthick Raj Mani ◽  
Suresh Poudel ◽  
K J Maria Das

Abstract Purpose: To investigate the cardio-pulmonary doses between Deep Inspiration Breath Hold (DIBH) and Free Breathing (FB) technique in left sided breast irradiation. Materials & Methods: DIBH CT and FB CT were acquired for 10 left sided breast patients who underwent whole breast irradiation with or without nodal irradiation. Three fields single isocenter technique were used for patients with node positive patients along with two tangential conformal fields whereas only two tangential fields were used in node negative patients. All the critical structures like lungs, heart, esophagus, thyroid, etc., were delineated in both DIBH and FB scan. Both DIBH and FB scans were fused with the Dicom origin as they were acquired with the same Dicom coordinates. Plans were created in the DIBH scan for a dose range between 50 Gy in 25 fractions. Critical structures doses were recorded from the Dose Volume Histogram for both the DIBH and FB data set for evaluation. Results: The average mean heart dose in DIBH vs FB was 13.18 Gy vs 6.97 Gy, (p = 0.0063) significantly with DIBH as compared to FB technique. The relative reduction in average mean heart dose was 47.12%. The relative V5 reduced by 14.70% (i.e. 34.42% vs 19.72%, p = 0.0080), V10 reduced by 13.83% (i.e. 27.79 % vs 13.96%, p = 0.0073). V20 reduced by 13.19% (i.e. 24.54 % vs 11.35%, p = 0.0069), V30 reduced by 12.38% (i.e. 22.27 % vs 9.89 %, p = 0.0073) significantly with DIBH as compared to FB. The average mean left lung dose reduced marginally by 1.43 Gy (13.73 Gy vs 12.30 Gy, p = 0.4599) but insignificantly with DIBH as compared to FB. Other left lung parameters (V5, V10, V20 and V30) shows marginal decreases in DIBH plans compare to FB plans. Conclusion: DIBH shows a substantial reduction of cardiac doses but slight and insignificant reduction of pulmonary doses as compared with FB technique. Using the simple DIBH technique, we can effectively reduce the cardiac morbidity and at the same time radiation induced lung pneumonitis is unlikely to increase.


2020 ◽  
Vol 61 (3) ◽  
pp. 447-456 ◽  
Author(s):  
Ryohei Yamauchi ◽  
Norifumi Mizuno ◽  
Tomoko Itazawa ◽  
Hidetoshi Saitoh ◽  
Jiro Kawamori

Abstract Deep inspiration breath hold (DIBH) is a common method used worldwide for reducing the radiation dose to the heart. However, few studies have reported on the relationship between dose reduction and patient-specific parameters. The aim of this study was to compare the reductions of heart dose and volume using DIBH with the dose/volume of free breathing (FB) for patients with left-sided breast cancer and to analyse patient-specific dose reduction parameters. A total of 85 Asian patients who underwent whole-breast radiotherapy after breast-conserving surgery were recruited. Treatment plans for FB and DIBH were retrospectively generated by using an automated breast planning tool with a two-field tangential intensity-modulated radiation therapy technique. The prescribed dose was 50 Gy in 25 fractions. The dosimetric parameters (e.g., mean dose and maximum dose) in heart and lung were extracted from the dose–volume histogram. The relationships between dose–volume data and patient-specific parameters, such as age, body mass index (BMI), and inspiratory volume, were analyzed. The mean heart doses for the FB and DIBH plans were 1.56 Gy and 0.75 Gy, respectively, a relative reduction of 47%. There were significant differences in all heart dosimetric parameters (p < 0.001). For patients with a high heart dose in the FB plan, a relative reduction of the mean heart dose correlated with inspiratory volume (r = 0.646). There was correlation between the relative reduction of mean heart dose and BMI (r = −0.248). We recommend considering the possible feasibility of DIBH in low BMI patients because the degree of benefit from DIBH varied with BMI.


2021 ◽  
Vol 0 (0) ◽  
Author(s):  
Michał Falco ◽  
Bartłomiej Masojć ◽  
Agnieszka Macała ◽  
Magdalena Łukowiak ◽  
Piotr Woźniak ◽  
...  

Abstract Background Patients with left breast cancer who undergo radiotherapy have a non-negligible risk of developing radiation-induced cardiovascular disease (CVD). Cardioprotection can be achieved through better treatment planning protocols and through respiratory gating techniques, including deep inspiration breath hold (DIBH). Several dosimetric studies have shown that DIBH reduces the cardiac dose, but clinical data confirming this effect is limited. The aim of the study was to compare the mean heart dose (MHD) in patients with left breast cancer who underwent radiotherapy at our institution as we transitioned from non-gated free-breathing (FB) radiotherapy to gated radiotherapy (FB-GRT), and finally to DIBH. Patients and methods Retrospective study involving 2022 breast cancer patients who underwent radiotherapy at West Pomeranian Oncology Center in Szczecin from January 1, 2014 through December 31, 2017. We compared the MHD in these patients according to year of treatment and technique. Results Overall, the MHD for patients with left breast cancer in our cohort was 3.37 Gy. MHD values in the patients treated with DIBH were significantly lower than in patients treated with non-gated FB (2.1 vs. 3.48 Gy, p < 0.0001) and gated FB (3.28 Gy, p < 0.0001). The lowest MHD values over the four-year period were observed in 2017, when nearly 85% of left breast cancer patients were treated with DIBH. The proportion of patients exposed to high (> 4 Gy) MHD values decreased every year, from 40% in 2014 to 7.9% in 2017, while the percentage of patients receiving DIBH increased. Conclusions Compared to free-breathing techniques (both gated and non-gated), DIBH reduces the mean radiation dose to the heart in patients with left breast cancer. These findings support the use of DIBH in patients with left breast cancer treated with radiotherapy.


2016 ◽  
Vol 16 (1) ◽  
pp. 22-32 ◽  
Author(s):  
Steve Walston ◽  
Allison M. Quick ◽  
Karla Kuhn ◽  
Yi Rong

Purpose: To present our clinical workflow of incorporating AlignRT for left breast deep inspiration breath-hold treatments and the dosimetric considerations with the deep inspiration breath-hold protocol. Material and Methods: Patients with stage I to III left-sided breast cancer who underwent lumpectomy or mastectomy were considered candidates for deep inspiration breath-hold technique for their external beam radiation therapy. Treatment plans were created on both free-breathing and deep inspiration breath-hold computed tomography for each patient to determine whether deep inspiration breath-hold was beneficial based on dosimetric comparison. The AlignRT system was used for patient setup and monitoring. Dosimetric measurements and their correlation with chest wall excursion and increase in left lung volume were studied for free-breathing and deep inspiration breath-hold plans. Results: Deep inspiration breath-hold plans had significantly increased chest wall excursion when compared with free breathing. This change in geometry resulted in reduced mean and maximum heart dose but did not impact lung V20 or mean dose. The correlation between chest wall excursion and absolute reduction in heart or lung dose was found to be nonsignificant, but correlation between left lung volume and heart dose showed a linear association. It was also identified that higher levels of chest wall excursion may paradoxically increase heart or lung dose. Conclusion: Reduction in heart dose can be achieved for many left-sided breast and chest wall patients using deep inspiration breath-hold. Chest wall excursion as well as left lung volume did not correlate with reduction in heart dose, and it remains to be determined what metric will provide the most optimal and reliable dosimetric advantage.


2019 ◽  
Vol 19 (2) ◽  
pp. 122-126
Author(s):  
Yuen Yan Chan ◽  
Ki Man Ku ◽  
Yin Ping Ng ◽  
Siu Ki Ben Yu ◽  
Chi Wah Tony Kong ◽  
...  

AbstractBackground:An in-house self-held respiration monitoring device (SHRMD) was developed for providing deep inspiration breath hold (DIBH) radiotherapy. The use of SHRMD is evaluated in terms of reproducibility, stability and heart dose reduction.Methods and materials:Sixteen patients receiving radiotherapy of left breast cancer were planned for treatment with both a free breathing (FB) scan and a DIBH scan. Both FB and DIBH plans were generated for comparison of the heart, left anterior descending (LAD) artery and lung dose. All patients received their treatments with DIBH using SHRMD. Megavoltage cine images were acquired during treatments for evaluating the reproducibility and stability of treatment position using SHRMD.Results:Compared with FB plans, the maximum dose to the heart by DIBH technique with SHRMD was reduced by 29·9 ± 15·6%; and the maximum dose of the LAD artery was reduced by 41·6 ± 18·3%. The inter-fractional overall mean error was 0·01 cm and the intra-fractional overall mean error was 0·04 cm.Conclusion:This study demonstrated the potential benefits of using the SHRMD for DIBH to reduce the heart and LAD dose. The patients were able to perform stable and reproducible DIBHs.


Sign in / Sign up

Export Citation Format

Share Document