scholarly journals SAT-067 AGREEMENT BETWEEN POINT-OF-CARE-BLOOD GAS ANALYZER AND CENTRAL LABORATORY AUTO ANALYZER IN PATIENTS WITH HYPERKALAEMIA

2020 ◽  
Vol 5 (3) ◽  
pp. S29-S30
Author(s):  
P. KASSUM
2012 ◽  
Vol 2012 ◽  
pp. 1-7 ◽  
Author(s):  
Tetsuya Makiishi ◽  
Naomasa Nishimura ◽  
Keiko Yoshioka ◽  
Shinya Yamamoto ◽  
Ryuichi Mitsuhashi ◽  
...  

Background. To address the cause(s) of the significant differences in chloride (Cl-) concentrations between point-of-care blood gas analyzers and central laboratory analyzers.Methods. Cl-concentrations measured simultaneously by a blood gas analyzer (ABL800 FLEX) and a central laboratory analyzer (Hitachi7600) were collected in patients with severe acidemia (pH<7.20) (n=32) and were examined for correlations between differences in Cl-and factors associated with the acid-base status. Cl-concentrations were measured with both analyzers for samples with different concentrations of lactate, inorganic phosphate, or bicarbonate (HCO3   −).Results. The differences in Cl-concentrations were correlated withHCO3   −concentrations (r=0.72,P<0.0001) and anion gap (r=0.69,P<0.0001). Only the addition ofHCO3   −proportionately increased Cl-levels measured by a Hitachi7600, but it did not affect those measured by an ABL800FLEX.Conclusion. Cl-measurements with some analyzers may be influenced byHCO3   −concentrations, which could result in the observed discrepancies.


2018 ◽  
Vol 42 (5) ◽  
pp. 189-193
Author(s):  
Tevfik Honca ◽  
Mehtap Honca

AbstractBackgroundThe aim of the present study was to compare hemoglobin (Hb) levels determined by point-of-care testing (POCT) HemoCue® and arterial blood gas analyzer using an automated hematology analyzer in critically ill geriatric patients.MethodsForty geriatric patients requiring intensive care treatment were included in the study. Arterial blood sample was analyzed using HemoCue® (HemoCue®; Hb 201+, Angelholm, Sweden) (HbHemoCueArterial), blood gas analyzer (Techno Medica, Gastat1800 series, Japan) (HbBGA) and an automated hematology analyzer (Cell Dyne 3700 System, Abbott Laboratories, USA) (HbLab) as a reference method. Capillary blood measurements were performed (HbHemoCueCapillary) using HemoCue® at bedside. Bland-Altman analysis was applied to the results.ResultsWe found a positive correlation between the Hb measurements of HemoCueCapillary, HemoCueArterial and automated hematology analyzer (r-values were 0.799 and 0.922, respectively) and p<0.001. There was also a positive correlation between the Hb measurements of blood gas analyzer and automated hematology analyzer (r = 0.878) and p<0.001. The bias and limits of agreement were 0.32 and −2.5±3.14 g/dL for the HbHemoCueCapillary, 0.64 and −1.03±2.31 g/dL for the HbHemoCueArterial and −1.2 and −4.45±2.05 g/dL for the HbBGA. Inotropic agent administration did not affect the Hb values in all groups.ConclusionsBoth HemoCueCapillary and HemoCueArterial are sufficiently accurate and correlated with automated hematology analyzer in geriatric critically ill patients if used correctly. In terms of Hb levels, arterial and capillary blood sample measurements with HemoCue® provided more clinically acceptable accuracy than blood gas analysis system.


Author(s):  
Bénédicte Bénéteau-Burnat ◽  
Marie-Chantal Bocque ◽  
Anne Lorin ◽  
Catherine Martin ◽  
Michel Vaubourdolle

AbstractDuring the past few decades, new technologies have allowed the fabrication of miniaturized sensors and the development of analyzers well designed for point-of-care testing (POCT). They combined the ease-of-use and portability required for POC with the accuracy and the reliability of traditional systems. Instrumentation Laboratory introduced the GEM


2019 ◽  
Vol 493 ◽  
pp. S656
Author(s):  
L.M. Martínez Sánchez ◽  
S. Lafuente Muro ◽  
L. Castillo Ribelles ◽  
M. Martínez Casademont

Sign in / Sign up

Export Citation Format

Share Document