Predicting thermal comfort in office buildings in a Brazilian temperate and humid climate

2017 ◽  
Vol 144 ◽  
pp. 152-166 ◽  
Author(s):  
Ricardo Forgiarini Rupp ◽  
Enedir Ghisi
2021 ◽  
Vol 1144 (1) ◽  
pp. 012029
Author(s):  
F Abass ◽  
L H Ismail ◽  
I A Wahab ◽  
W A Mabrouk ◽  
H Kabrein

Energies ◽  
2017 ◽  
Vol 10 (9) ◽  
pp. 1368 ◽  
Author(s):  
Georgios Kontes ◽  
Georgios Giannakis ◽  
Philip Horn ◽  
Simone Steiger ◽  
Dimitrios Rovas

Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6597
Author(s):  
Ahmet Bircan Atmaca ◽  
Gülay Zorer Gedik ◽  
Andreas Wagner

Mosques are quite different from other building types in terms of occupant type and usage schedule. For this reason, they should be evaluated differently from other building types in terms of thermal comfort and energy consumption. It is difficult and probably not even necessary to create homogeneous thermal comfort in mosques’ entire usage area, which has large volumes and various areas for different activities. Nevertheless, energy consumption should be at a minimum level. In order to ensure that mosques are minimally affected by outdoor climatic changes, the improvement of the properties of the building envelope should have the highest priority. These optimal properties of the building envelope have to be in line with thermal comfort in mosques. The proposed method will be a guide for designers and occupants in the design process of new mosques or the use of existing mosques. The effect of the thermal properties of the building envelope on energy consumption was investigated to ensure optimum energy consumption together with an acceptable thermal comfort level. For this purpose, a parametric simulation study of the mosques was conducted by varying optical and thermal properties of the building envelope for a temperature humid climate zone. The simulation results were analyzed and evaluated according to current standards, and an appropriate envelope was determined. The results show that thermal insulation improvements in the roof dome of buildings with a large volume contributed more to energy savings than in walls and foundations. The use of double or triple glazing in transparent areas is an issue that should be considered together with the solar energy gain factor. Additionally, an increasing thickness of thermal insulation in the building envelope contributed positively to energy savings. However, the energy savings rate decreased after a certain thickness. The proposed building envelope achieved a 33% energy savings compared to the base scenario.


Author(s):  
Pritam Roy

Abstract: This research paper presents the investigation of design consideration to achieve thermal comfort and the warm humid climatic zone of West Bengal is considered as the primary study area for the investigation. The varying thermal comfort behavior of humans in different climate conditions and seasons clearly demonstrates that the building design strategy must conform with the region of the building. In this paper, first studying the climatic characteristics of the warm humid region design factors are selected like building materials, cross ventilation, building orientation, roofing orientation, and materials, etc. After that, all those design factors are studied and the effect of all those factors on building in various conditions is observed. Keywords: Warm Humid Climate, Thermal Comfort, Building Materials, U-value, Cross Ventilation, Building Orientation


2012 ◽  
Vol 48 ◽  
pp. 7-14 ◽  
Author(s):  
Nastaran Makaremi ◽  
Elias Salleh ◽  
Mohammad Zaky Jaafar ◽  
AmirHosein GhaffarianHoseini

Sign in / Sign up

Export Citation Format

Share Document