Energy, exergy, economic and environmental analysis of refrigerant charge in air source transcritical carbon dioxide heat pump water heater

2020 ◽  
Vol 223 ◽  
pp. 113209 ◽  
Author(s):  
Yikai Wang ◽  
Zuliang Ye ◽  
Yulong Song ◽  
Xiang Yin ◽  
Feng Cao
2011 ◽  
Vol 71-78 ◽  
pp. 2266-2270 ◽  
Author(s):  
Kang Liu ◽  
Jing Lv ◽  
Song Bo Zhang ◽  
Jie Yang

In the design of a carbon dioxide heat pump water heater evaporator, the effect of the circuit number on the evaporator is investigated numerically by EVAP-COND 3.0 version simulation package of American National Institute of Standards and Technology. It is found that as the circuit number increases the temperature difference between the air and the refrigerant increases, but it reduces the overall heat transfer coefficient. The evaporator capacity will rise firstly, and then drop with the circuit number and achieve the maximum in the optimum circuit number. Therefore, selecting the appropriate circuit number of the evaporator can significantly improve the efficiency and optimize the design.


Author(s):  
Hirosi Nakayama ◽  
Mitsuharu Uchida ◽  
Masahide Higuchi ◽  
Yutaka Shibata ◽  
Yasuhiko Oka

2013 ◽  
Vol 19 (7) ◽  
pp. 823-835 ◽  
Author(s):  
Michael Petersen ◽  
Chad Bowers ◽  
Stefan Elbel ◽  
Pega Hrnjak

2014 ◽  
Vol 134 (9) ◽  
pp. 1276-1281
Author(s):  
Eitaro Omine ◽  
Masahiro Asari ◽  
Hiromu Kobayashi

1979 ◽  
Author(s):  
J.T. Dieckmann ◽  
A.J. Erickson ◽  
A.C. Harvey ◽  
W.M. Toscano

2021 ◽  
Vol 39 ◽  
pp. 102547
Author(s):  
Sami Missaoui ◽  
Zied Driss ◽  
Romdhane Ben Slama ◽  
Bechir Chaouachi

Sign in / Sign up

Export Citation Format

Share Document