A critical assessment of the compressive behavior of reinforced recycled aggregate concrete columns

2018 ◽  
Vol 161 ◽  
pp. 161-175 ◽  
Author(s):  
Jin-Jun Xu ◽  
Zong-Ping Chen ◽  
Togay Ozbakkaloglu ◽  
Xin-Yu Zhao ◽  
Cristoforo Demartino
2018 ◽  
Vol 21 (15) ◽  
pp. 2299-2310 ◽  
Author(s):  
Jiachuan Yan ◽  
Kaihua Liu ◽  
Chaoying Zou ◽  
Jian Wang

The eccentric compressive behavior of 18 recycled aggregate concrete columns after freezing and thawing cycles were investigated. The effect of the number of freezing and thawing cycles, the replacement ratio of recycled coarse aggregate, and the eccentricity of axial loading on the eccentric compressive behavior of columns was analyzed. The results show that the strain distribution along the depth of cross section of columns was plane during the eccentric compression test after freezing and thawing cycles. With the increase in the freezing and thawing cycles and the replacement ratio of recycled coarse aggregate, the failure modes of partial specimens turned from ductile tension failure to brittle compression failure. Two existing design methods for calculating the bearing capacity of conventional concrete columns subjected to eccentric compressive loading were verified to be effective for evaluating that of recycled aggregate concrete columns after limited freezing and thawing cycles.


Author(s):  
Sung-Mo Choi ◽  
Won Ho Choi ◽  
Kangseok Lee ◽  
Jae-Yong Ryoo ◽  
Sunhee Kim ◽  
...  

Recycled aggregate is an environmentally self-sustainable solution that can reduce construction waste and replace natural aggregates. However, there is a disadvantage in concrete such as initial strength drop and long-term strength development. Therefore, the interaction effect of the two materials can be expected by filling the cyclic aggregate concrete in the CFT column. In order to develop a concrete with compressive strength of 50 MPa as a recycled aggregate, we carried out a mixing experiment and fabricated 18 specimens to confirm the compressive behavior of a RCFT (Recycled Concrete Filled Tube) column that can be applied to actual buildings. Variable is the shape and thickness of steel pipe, concrete strength and mixing ratio, and coarse aggregate and fine aggregate are all used as recycled aggregate. The optimum mixing ratio for recycled aggregate concrete to be filled in the CFT filled steel pipe was found through three concrete preliminary mixing experiments. In addition, the compression test of the RCFT column was carried out to observe and analyze the buckling shape of the CFT column. Based on the analysis of the buckling configuration and the experimental data, the load-displacement curves of the specimens were drawn and the compressive behavior was analyzed. 


Sign in / Sign up

Export Citation Format

Share Document