Proceedings 12th international conference on Advances in Steel-Concrete Composite Structures - ASCCS 2018
Latest Publications


TOTAL DOCUMENTS

117
(FIVE YEARS 0)

H-INDEX

2
(FIVE YEARS 0)

Published By Universitat Politècnica València

9788490486016

Author(s):  
Kevin Wolters ◽  
Markus Feldmann

The current fatigue design of composite dowels is based on the structure stress concept for the steel part and upper load limitations to avoid concrete fatigue and a degradation of the composite joint. Therefore the aim of the existing concept is to avoid any fatigue of the composite structure. A fatigue concept considering residual load bearing capacity of torn steel connectors and the transfer of forces to less stressed composite dowels in the beam has great economic potential and leads to a better safety assessment. Therefore, further investigations of fatigue behaviour and crack propagation of composite dowels are necessary. In a first step a single composite dowel is investigated in small-part tests. By the use of finite element models a new inclined single push-out test stand has been developed in order to reproduce the force and stress distributions within a composite beam as precisely as possible with the small-part tests. This ensures the comparability of the crack initiation location and crack propagation. In the test series the influences of different stress ranges and cycle numbers on crack propagation of the steel dowel are investigated. Furthermore the residual load-bearing capacity is determined and compared to static load-bearing behaviour of uncracked steel parts of composite dowels. This paper concentrates on the numerical evaluation of crack propagation and residual capacity.


Author(s):  
Guoqiang LI ◽  
Mengde PANG ◽  
Feifei Sun ◽  
Liulian LI ◽  
Jianyun SUN

Coupled shear walls are widely used in high rise buildings, since they can not only provide efficient lateral stiffness but also behave outstanding energy dissipation ability especially for earthquake-resistance. Traditionally, the coupling beams are made of reinforced concrete, which are prone to shear failure due to low aspect ratio and greatly reduce the efficiency and ability of energy dissipation.  For overcoming the shortcoming of concrete reinforced coupling beams (RCB), an innovative steel coupling beams called two-level-yielding steel coupling beam (TYSCB) is invented to balance the demand of stiffness and energy dissipation for coupled shear walls. TYSCBs are made of two parallel steel beams with yielding at two different levels.  To verify and investigate the aseismic behaviour improvement of TYSCB-coupled shear walls, two 1/3 scale, 10-storey coupled shear wall specimens with TYSCB and RCB were tested under both gravity and lateral displacement reversals. These two specimens were designed with the same bearing capacity, thus to be easier to compare. The experimental TYSCB specimen demonstrated more robust cyclic performance. Both specimens reached 1% lateral drift, however, the TYSCB-coupled shear wall showed minimal strength degradation. Additionally, a larger amount of energy was dissipated during each test of the TYSCB specimen, compared with the RCB specimen. Based on the experimental results, design recommendations are provided.


Author(s):  
Mohammed Abdulhussein Al-Shuwaili ◽  
Alessandro Palmeri ◽  
Maria Teresa Lombardo

Push-out tests (POTs) have been widely exploited as an alternative to the more expensive full-scale bending tests to characterize the behaviour of shear connections in steel-concrete composite beams. In these tests, two concrete slabs are typically attached to a steel section with the connectors under investigation, which are then subjected to direct shear. The results allow quantifying the relationship between applied load and displacements at the steel-concrete interface. Since this relationship is highly influenced by the boundary conditions of POT samples, different experimental setups have been used, where the slabs are either restricted or free to slide horizontally, as researchers have tried to reduce any discrepancy between POT and full-scale composite beam testing. Based on a critical review of various POT configurations presented in the dedicated literature, this paper presents an efficient one-sided POT (OSPOT) method. While OSPOT and POT specimens are similar, in the proposed OPSPOT setup only one of the two slabs is directly loaded in each test, and the slab is free to move vertically. Thus, two results can be obtained from one specimen, i.e. one from each slab. A series of POTs and OSPOTs have been conducted to investigate the behaviour and the shear resistance of headed stud connectors through the two methods of testing. The results of this study than were compared with those of different POTs setups conducted by other researchers. The new OSPOT results show in general an excellent agreement with the analytical predictions offered by both British and European standards, as well as the estimated shear resistance proposed other researchers in the literature. These findings suggest that the proposed one-sided setup could be used as an efficient and economical option for conducting the POT, as it has the potential not only to double the number of results, but also to simplify the fabrication of the samples, which is important in any large experimental campaign, and to allow testing with limited capacity of the actuator. 


Author(s):  
Shinya Nakaue ◽  
Yasushi Nishimura

To improve the bearing failure behavior of the exterior steel beam-reinforced concrete column joints composed of reinforced concrete columns, joint details using steel column was proposed. Steel column was attached to the lower flanges at right angles to the steel flange. The objective of this study is to clarify the effectiveness of proposed joint details experimentally and theoretically. To clarify the influence of steel column on the bearing failure of the joint, seven T-shaped subassemblages were tested under reversed cyclic loading. All specimens had the same cross sections of the steel beam. The experimental variables were the embedded length of the steel column, whether there is the end plate at the tip of the embedded steel column, and, the arrangement of transverse reinforcement ratio surrounding the steel column. The following remarks can be drawn from the test results. 1) In case of the specimen with a short embedded length of the steel column, the punching shear failure on the upper surface of the steel beam flange was remarkable when the maximum strength was reached. However, in the specimen with long embedded length of steel column, it was not observed the punching shear failure. 2) The maximum strength increased with the embedded length of the steel column. Further, the maximum strength of the specimen with the embedded length of three times of the steel column depths is subjected to bending yield strength of the steel column. 3) It was shown that the transverse reinforcement to surround the steel column and the end plate were necessary to improve the bearing failure of the joint. 


Author(s):  
Guochang Li ◽  
Zhichang Zhan ◽  
Zhijian Yang ◽  
Yu Yang

The concrete-filed square steel tube with inner I-shaped CFRP profiles short columns under bi-axial eccentric load were investigated by the finite element analysis software ABAQUS. The working mechanism of the composite columns which is under bi-axial eccentric load are investigated by using the stress distribution diagram of steel tube concrete and the I-shaped CFRP profiles. In this paper, the main parameters; eccentric ratio, steel ratio, steel yield strength, concrete compressive strength and CFRP distribution rate of the specimens were investigated to know the mechanical behavior of them. The interaction between the steel tube and the concrete interface at different characteristic points of the composite columns were analyzed. The results showed that the ultimate bearing capacity of the concrete-filed square steel tube with inner I-shaped CFRP profiles short columns under bi-axial eccentric load decrease with the increase of eccentric ratio, the ultimate bearing capacity of the composite columns increase with the increase of steel ratio, steel yield strength, concrete compressive strength and CFRP distribution rate. The contact pressure between the steel tube and the concrete decreased from the corner zone to the flat zone, and the contact pressure decreased from the mid-height cross section to other sections.


Author(s):  
Lin-Hai Han ◽  
Dan-Yang Ma ◽  
Kan Zhou

Concrete-encased CFST (concrete-filled steel tube) is a kind of composite structure comprised of a CFST component and a reinforced concrete (RC) component. The concrete encased CFST possesses superior ductility and higher stiffness. They are gaining popularity in high-rise buildings, large-span structures, bridges, subway stations and workshops. This paper initially reviews the recent research on concrete-encased CFST structures. The major research findings on bond performance, static performance, dynamic performance and fire resistance are presented. This paper also outlines some construction considerations, such as the utilization of materials, the fabrication of the steel tube, and the methods of casting the inner and outer concrete. Finally, some typical practical projects utilizing concrete-encased CFST members are presented and reviewed.


Author(s):  
Hervé Degée ◽  
Yves Duchêne ◽  
Benno Hoffmeister

The aim of the recently completed European research program Meakado is therefore to study design options with requirements proportioned to the actual seismic context of constructions in areas characterized by a low or moderate seismic hazard, contrary to most researches aiming at maximizing the seismic performances. In this general framework, specific investigations have been carried out regarding typical beam profiles commonly used for multi-bay - multi-storey composite frames. In a first stage, experimental tests on class-3 composite beam-to-column connections were performed. The measurement results were evaluated with regard to the development of the hysteretic behavior with particular emphasis on the degradation. These test results have been used as reference for the calibration and validation of numerical model aiming at extending the scope of the experimental outcomes through appropriate parametric variations regarding the behavior of nodal connections as well as towards the global analysis and behavior of structures made of class 3 and 4 profiles. Numerical investigations of the global performance of composite frames with slender cross-sections are then performed resorting to the numerical model previously calibrated with respect to the experimental tests and additional simulations at node level. Results are compared to the performance of an equivalent frame made of compact steel profiles. Attention is paid to the effects of strength and stiffness degradation due to local buckling. The analysis of the results is specifically focusing on the comparison of the rotation capacity of the slender section with the actual rotation demand imposed by a moderate intensity earthquake. Based on the outcomes of these investigations, practical design recommendations are finally derived for multi-storey, multi-bay moment resisting frames with type b (full composite action) beam-to column connections located in low and moderate seismicity regions. 


Author(s):  
Vicente Albero ◽  
Ana Espinós ◽  
Enrique Serra ◽  
Manuel L. Romero ◽  
Antonio Hospitaler

Steel-concrete composite beams embedded in floors (slim-floors) offer various advantages such as the floor thickness reduction or the ease of installation of under-floor technical equipment. However, this typology presents important differences in terms of thermal behaviour, as compared to other composite beams, when exposed to elevated temperatures. These differences are due to their special configuration, being totally contained within the concrete floor depth. Moreover, the current European fire design code for composite steel-concrete structures (EN 1994-1-2) does not provide any simplified thermal model to evaluate the temperature evolution of each slim-floor part during a fire. Additionally, only a few experimental studies can be found which may help understand the thermal behaviour of these composite beams. This paper presents an experimental investigation on the thermal behaviour of slim-floor beams. Electrical radiative panels were used in the test setup to produce the thermal heating. The thermal gap between the lower flange of the steel profile and the bottom steel plate was studied, being found to be one of the most influential elements over the cross-section temperature gradient. The experimental campaign was developed by varying the cross-section configuration in order to evaluate the influence of this parameter over the slim-floor thermal behavior. Finally, the experiments carried out were used to develop and calibrate a finite element thermal model which may help in further research on the thermal behaviour of slim-floor composite beams.


Author(s):  
Xiao Liu ◽  
Jianye Xu ◽  
Bing Wang

Abstract: To analysis the behavior of the mechanical properties of concrete-filled double skin steel tubular (CFDST) columns under eccentric loads after fire, the finite element analysis was used. The established FEA modeling was verified by the experimental results which has a good agreement. The FEA modeling was then used to perform the temperature field and the full-range load-deformation relations of the CFDST subject to eccentric compression after exposed to fire. The results indicate that: with the time of fire increasing, the eccentric distance increasing, the steel ratio decreasing, the yield strength decreasing and compressive strength decreasing, the bearing capacity of CFDST in circle section under eccentric loads is showing a decrease trend, and the stiffness of component decreases with the time of fire increasing, the eccentric distance increasing and the steel ratio decreasing. The ductility of CFDST became better with the time of fire increasing and the eccentric distance increasing.


Author(s):  
Teodora Bogdan ◽  
Maciej Chrzanowski

Steel reinforced concrete (SRC) columns are widely used in super high-rise buildings, since they can provide larger load bearing capacity and better ductility than traditional reinforced concrete (RC) columns. Six concrete – encased composite columns were designed based on a typical mega-column of a super high-rise building constructed in China. The specimens are identical in geometrical configurations having as changing parameter the eccentricity ratio of the applied load: every two of the specimens were loaded statically with the eccentricity ratio of 0, 10%, and 15%, respectively. Such columns are however not covered by EN 1994-1-1 [2] (limited to one single encased profile), while AISC 360-16 [8] allows the design of composite sections built-up with two or more encased steel sections, although the way to perform such a design is not detailed. A finite element analysis was conducted as a supplement to the physical tests to provide a deeper insight into the behavior of SRC columns. The experimental campaign has yielded stable test results, suggesting a desirable performance of SRC columns. It is concluded from these experiments that sufficient composite action exists between the concrete and the steel sections for the tested SRC specimens, and that the current code provisions are applicable for the considered configuration, in predicting the flexural capacity of SRC columns when the eccentricity ratio is less than or equal to 15%. The present paper summarizes the principles and an application method for the design of such columns under combined axial compression and bending. The method is based on simplifications provided in EN 1994–1. The validation of the method is made using experimental and numerical results. 


Sign in / Sign up

Export Citation Format

Share Document