Comparison of short-circuit current calculations in DC shipboard power system for Fuse protection designing

2021 ◽  
Vol 199 ◽  
pp. 107353
Author(s):  
J.J. Deroualle ◽  
D. Pescatori ◽  
A. Dellacasa ◽  
C. Davico
Author(s):  
Wei Zhang ◽  
Weifeng Shi ◽  
Jinbao Zhuo

In order to improve shipboard power system dynamic stability, two bio-inspired algorithms, the genetic algorithm (GA) and quantum-behaved particle swarm optimization (QPSO), method are proposed for the shipboard power system stabilizer (PSS) optimization. The proposed PSS optimization method is inspired by a hybrid-coordinated stabilizer for diesel engine generator and the bio-inspired algorithm. The simulations are conducted under load change disturbance and short-circuit fault case for the marine generator with/without the diesel engine speed governor. Simulation results show that the quantum particle swarm optimize strategy could improve the dynamic performance of the marine generator better than the GA method. The dynamic performance for shipboard power system always indicates the effectiveness, feasibility and robustness of the proposed approach.


2009 ◽  
Vol 2 (4) ◽  
pp. 61-70
Author(s):  
Ravi Babu Pallikonda ◽  
◽  
K. Prapoorna ◽  
N.V. Prashanth ◽  
A. Shruti ◽  
...  

2021 ◽  
Vol 39 (5A) ◽  
pp. 723-737
Author(s):  
Yamur M. Obied ◽  
Thamir M. Abdul Wahhab

The coordination between protective devices is the process of determining the most appropriate timing of power interruption during abnormal conditions in the power system. The aim of this work is to coordinate the protection of the 33/11 kV power distribution substation in Iraq using the CYME 7.1 software package. In this paper overcurrent and earth fault relays are simulated in two cases, with time delay setting and instantaneous setting, to obtain the Time Current Characteristics (TCC) curves for each Circuit Breaker (CB) relay of Al-Karama substation (2×31.5 MVA, 33/11 kV) in Babil distribution network. The short circuit current at each CB is calculated and accordingly, the protection coordination for Al-Karama substation has been simulated. The TCC curves have been obtained in two cases for overcurrent and earth fault relays; in a case with time delay setting and in the case with the instantaneous setting. The setting takes into consideration the short circuit current at the furthest point of the longest outgoing feeder and the shortest outgoing feeder.


Author(s):  
Bart Diaz ◽  
Thomas H. Ortmeyer ◽  
Bruce Pilvelait ◽  
Mike Izenson ◽  
Weibo Chen ◽  
...  