Forensic-metrological considerations on assessment of compliance (or non-compliance) in forensic blood alcohol content determinations: A case study with software application

2016 ◽  
Vol 265 ◽  
pp. 144-152 ◽  
Author(s):  
Luca Zamengo ◽  
Giampietro Frison ◽  
Gianpaola Tedeschi ◽  
Samuela Frasson
2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Jean-François Hak ◽  
Farouk Tradi ◽  
Mickael Bobot ◽  
Pauline Brige ◽  
Paul Habert ◽  
...  

Objective. To evaluate the vascular occlusion and midterm tissue toxicity properties of a combination of ethylene-vinyl alcohol (EVOH) (Squid 18®) (75%) and alcohol (25%)—Alco-Squid 18—in a swine model. Materials and Methods. Alco-Squid 18 (75% Squid 18® mixed with 25% alcohol) (AS18) was compared to embolization with 96% alcohol alone and to embolization with Squid 18® (S18®) alone. An arteriovenous malformation (AVM) model was created in group 1 (n = 2). Each AVM model was then embolized with AS18 or S18® alone with evaluation of a ratio between the volume of embolic agent divided by the volume of the AVM (evaluated by CT). For group 2 (n = 5), each agent was tested on three different kidneys (upper pole kidney artery). Pre- and postinterventional CTs, angiographies, blood alcohol content dosages, and histological studies (3 months postintervention) were performed. Results. AS18 has better distal distribution than S18® alone, both in the kidneys (mean capsule-S18® distance: 3.9 mm (±0.23) and mean capsule-AS18 distance: 2.3 mm (±0.11) ( p = 0.029 ) and in the AVM model. Histological exploration found a higher rate of tubular necrosis with AS18 compared with S18® alone and alcohol alone (3.78 ± 0.44 compared to 2.33 ± 1.22 p   =  0 . 012 and 1.22 ± 0.67 p   < 0   . 0001 ). The blood alcohol content was negligible in all cases. Conclusion. AS18 can suggest a better distal sclerotic and embolic character as compared with S18® alone without systemic toxicity.


Author(s):  
Jerome Lapointe ◽  
Hélène-Sarah Bécotte-Boutin ◽  
Stéphane Gagnon ◽  
Simon Levasseur ◽  
Philippe Labranche ◽  
...  

One third of fatal car accidents and so much tragedies are due to alcohol abuse. These sad numbers could be mitigated if everyone had access to a breathalyzer anytime and anywhere. Having a breathalyzer built into a phone or a wearable could be the way to get around the reluctance to carry a separate device. Towards this goal, we propose an inexpensive breathalyzer that could be integrated in the screen of mobile devices. Our technology is based on the evaporation rate of the fog produced by the breath on the phone screen, which increases as a function of the breath alcohol content. The device simply uses a photodiode placed on the side of the screen to measure the signature of the scattered light intensity from the phone display that is guided through the stress layer of the Gorilla glass screen. A part of the display light is coupled to the stress layer via the evanescent field induced at the edge of the breath microdroplets. We demonstrate that the intensity signature measured at the detector can be linked to the blood alcohol content. We fabricated a prototype in a smartphone case powered by the phone&rsquo;s battery, controlled by an application software installed in the smartphone and tested it in real-world environments. Limitations and future work toward a fully operational device are discussed.


2020 ◽  
Vol 29 (7) ◽  
pp. 841-847
Author(s):  
Benjamin Cooper ◽  
Markus Gehrsitz ◽  
Stuart G. McIntyre

2013 ◽  
Vol 38 (3) ◽  
pp. 826-833 ◽  
Author(s):  
Marie Eliasen ◽  
Morten H. Rod ◽  
Trine Flensborg-Madsen ◽  
Jørgen H. Petersen ◽  
Morten Grønbaek ◽  
...  

Addiction ◽  
2002 ◽  
Vol 97 (7) ◽  
pp. 909-914 ◽  
Author(s):  
David T. Levy ◽  
Ted R. Miller ◽  
Sue Mallonee ◽  
Rebecca S. Spicer ◽  
Eduardo O. Romano ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document