scholarly journals Facilitating endoscopic submucosal dissection: the suture-pulley method significantly improves procedure time and minimizes technical difficulty compared with conventional technique: an ex vivo study (with video)

2014 ◽  
Vol 80 (3) ◽  
pp. 495-502 ◽  
Author(s):  
Hiroyuki Aihara ◽  
Nitin Kumar ◽  
Marvin Ryou ◽  
Wasif Abidi ◽  
Michele B. Ryan ◽  
...  
BMC Surgery ◽  
2020 ◽  
Vol 20 (1) ◽  
Author(s):  
Ryoji Ichijima ◽  
Mitsuru Esaki ◽  
Shun Yamakawa ◽  
Yosuke Minoda ◽  
Sho Suzuki ◽  
...  

Abstract Background Endoscopic submucosal dissection (ESD) for gastrointestinal neoplasms can be technically difficult for trainee endoscopists. Presently, there is no consensus for trainees to select the endo-knife type in ESD. Therefore, we conducted a comparison study of treatment outcomes between scissors-type and needle-type knives in ESD performed by trainees in an ex vivo porcine model. Methods This study was conducted on trainee endoscopists who participated in ESD hands-on seminars held in August 2018 and September 2019. A total of 22 trainees from 13 institutions were divided into two groups according to their endoscopic experience. Under expert supervision, each trainee performed two ESDs in porcine models, namely, scissor-type knife (ESD-S) and needle-type knife (ESD-N). The efficacy and safety, including the procedure time and rates of self-completion, en bloc resection, and complications, were compared between ESD-S and ESD-N. In subgroup analysis, we also investigated the predictors associated with the difficulty of ESD for trainees using multivariate logistic regression analysis. Results Eight trainees had an experience of over 1000 endoscopies (senior trainee: S-Trainee), whereas the others had an experience of less than 1000 endoscopies (junior trainee: J-Trainee). Among the S-Trainees, no significant differences were observed in any treatment outcome between ESD-S and ESD-N. Among the J-Trainees, the total procedure and mucosal incision times were significantly shorter in ESD-S than in ESD-N [total procedure time: 16.5 min (range 10.0–31.0) vs. 22.3 min (range 10.0–38.0), P = 0.018; circumferential incision time: 10.0 min (range 6–16) vs. 17.0 min (range 5.0–31.5); P = 0.019]. Regarding complications, muscular injury occurred in two patients during ESD-N performed by J-Trainees; however, no muscular injury occurred during ESD-S. In subgroup analysis, ESD-N was an independent predictive factor of difficult ESD (odds ratio 5.28, 95% confidence interval 1.25–22.30; P = 0.024). Conclusions This study revealed that trainees, particularly those who have experienced less than 1000 endoscopies, should opt for the scissor-type knife to perform ESD.


Endoscopy ◽  
2020 ◽  
Vol 52 (09) ◽  
pp. 780-785
Author(s):  
Seiichiro Abe ◽  
Yutaka Saito ◽  
Yusaku Tanaka ◽  
Mai Ego ◽  
Fumito Yanagisawa ◽  
...  

Abstract Background This study aimed to demonstrate the feasibility of endoscopic hand-suturing (EHS) and attainability of sustained closure after colorectal endoscopic submucosal dissection (ESD). Methods EHS was defined as uninterrupted endoscopic suturing of the mucosal defect after colorectal ESD using an absorbable barbed suture and a through-the-scope needle holder. Following individual EHS training using an ex vivo porcine colonic model, two experienced endoscopists performed EHS. Repeat colonoscopy was performed on the third or fourth day after ESD to examine the EHS site. The primary end point was the complete EHS closure rate, and secondary end points were sustained closure and post-ESD bleeding rates. Results 11 lesions were included. Median size of the mucosal defect was 38 mm (range 25 – 55 mm) and the lesion characteristics were as follows: lower rectum/upper rectum/ascending colon/cecum = 3/3/2/3, and 0-IIa/0-Is + IIa/others = 5/4/2. EHS was not attempted in two patients owing to difficulty in colonoscope reinsertion after ESD and intraoperative perforation, respectively. EHS was performed for nine lesions, and the complete EHS closure rate was 73 %. Median procedure time for suturing was 56 minutes (range 30 – 120 minutes) and median number of stitches was 8 (range 6 – 12). Sustained closure and post-ESD bleeding rates were 64 % and 9 %, respectively. Conclusions EHS achieved complete and sustained closure in the colorectum. However, EHS is not currently clinically applicable given the long procedure time. Further modifications of the technique and devices are desirable.


2018 ◽  
Vol 33 (2) ◽  
pp. 663-668 ◽  
Author(s):  
Akira Dobashi ◽  
Andrew C. Storm ◽  
Louis M. Wong Kee Song ◽  
Christopher J. Gostout ◽  
Jodie L. Deters ◽  
...  

Endoscopy ◽  
2017 ◽  
Vol 50 (06) ◽  
pp. 606-612 ◽  
Author(s):  
Taku Sakamoto ◽  
Yutaka Saito ◽  
Fumihiko Nakamura ◽  
Seiichiro Abe ◽  
Hiroyuki Takamaru ◽  
...  

Abstract Background Although submucosal dissection is useful for treating laterally spreading colorectal tumors, there is little information regarding the endoscopic treatment of large protruding colorectal neoplasms. Here, we aimed to evaluate the clinical outcomes of endoscopic submucosal dissection for protruding colorectal neoplasms ≥ 20 mm in diameter. Methods In total, 112 consecutive patients undergoing treatment between January 2005 and June 2017 were enrolled retrospectively. The study period was divided into six periods to evaluate any changes in outcomes over time. We reviewed all short-term clinical outcomes, including lesion characteristics, procedure time, and percentages of en bloc resection, curative resection, adverse events, and treatment discontinuation. Results The percentages of en bloc, en bloc R0, and en bloc curative resections were 88 %, 82 %, and 59 %, respectively. Perforation occurred in 11 patients (10 %), and the endoscopic procedure was discontinued in five patients (4 %) because of technical difficulty. For lesions ≥ 40 mm in diameter, the procedure time showed a statistically significant decreasing trend in the latter half of the study period. However, the rate of cure did not improve along with enhancements to the procedure’s technological aspects. Conclusions Although endoscopic submucosal dissection for large protruding lesions has advanced in terms of its technical aspects, its ability to cure large protruding neoplasms has not shown gratifying results.


2021 ◽  
Vol 09 (08) ◽  
pp. E1207-E1213
Author(s):  
Kavel Visrodia ◽  
Tarek Sawas ◽  
Liam Zakko ◽  
Juan Reyes Genere ◽  
Cadman Leggett ◽  
...  

Abstract Background and study aims Endoscopic submucosal dissection (ESD) is technically challenging, difficult to learn, and carries a substantial risk of perforation, all of which remain significant barriers to its adoptability. We aimed to determine whether use of a novel scissor-type knife improved efficacy and safety among novice performers of ESD. Materials and methods Following a brief didactic session on ESD, participants performed ESD of two lesions (2 cm diameter) in an ex vivo porcine gastric model. One resection was performed with a conventional knife and the other with the scissor knife (order of knife randomized). We recorded procedure time, successful en bloc resection, and adverse events (including full-thickness perforation and muscle injury) for each dissection. Participants completed a post-study survey. Results 10 endoscopists (8 trainees, 2 staff) considered novices in ESD participated. Compared with the conventional knife, use of the scissor knife was associated with a significantly shorter time to completion of submucosal dissection (mean 6.2 [SD 5.6] vs. 15.6 [SD 15.6] minutes; P = 0.04) and total procedure time was not significantly different (22.1 [SD 13.3] vs. 24.9 [SD 26.5] minutes; P = 0.65). Scissor knife use was also associated with a significantly lower proportion of perforation and/or muscle injury (10.0 % vs. 70.0 %; P < 0.01) and proportion of muscle injury alone (10.0 % vs. 60.0 %; P  = 0.02). Conclusions Among novices performing ESD on an ex vivo animal model, use of a scissor knife was associated with a significantly lower proportion of adverse events without prolonging procedure time. Scissor-type knives may improve ESD safety, at least among novices.


Sign in / Sign up

Export Citation Format

Share Document