“Pulmonary valve replacement diminishes the presence of restrictive physiology and reduces atrial volumes”: A prospective study in Tetralogy of Fallot patients

2014 ◽  
Vol 177 (1) ◽  
pp. 261-265 ◽  
Author(s):  
Antonia Pijuan-Domenech ◽  
Victor Pineda ◽  
Miguel Angel Castro ◽  
Carlos Sureda-Barbosa ◽  
Aida Ribera ◽  
...  
2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
E Havers-Borgersen ◽  
J.H Butt ◽  
M Groening ◽  
M Smerup ◽  
G.H Gislason ◽  
...  

Abstract Introduction Patients with tetralogy of Fallot (ToF) are considered at high risk of infective endocarditis (IE) as a result of altered hemodynamics and multiple surgical and interventional procedures including pulmonary valve replacement (PVR). The overall survival of patients with ToF has increased in recent years. However, data on the risk of adverse outcomes including IE are sparse. Purpose To investigate the risk of IE in patients with ToF compared with controls from the background population. Methods In this nationwide observational cohort study, all patients with ToF born in 1977–2017 were identified using Danish nationwide registries and followed from date of birth until occurrence of an outcome of interest (i.e. first-time IE), death, or end of study (July 31, 2017). The comparative risk of IE among ToF patients versus age- and sex-matched controls from the background population was assessed. Results A total of 1,156 patients with ToF were identified and matched with 4,624 controls from the background population. Among patients with ToF, 266 (23.0%) underwent PVR during follow-up. During a median follow-up time of 20.4 years, 38 (3.3%) patients and 1 (0.03%) control were admitted with IE. The median time from date of birth to IE was 10.8 years (25th-75th percentile 2.8–20.9 years). The incidence rates of IE per 1,000 person-years were 2.2 (95% confidence interval (CI) 1.6–3.0) and 0.01 (95% CI 0.0001–0.1) among patients and controls, respectively. In multivariable Cox regression models, in which age, sex, pulmonary valve replacement, and relevant comorbidities (i.e. chronic renal failure, diabetes mellitus, presence of cardiac implantable electronic devices, other valve surgeries), were included as time-varying coefficients, the risk of IE was significantly higher among patients compared with controls (HR 171.5, 95% CI 23.2–1266.7). Moreover, PVR was associated with an increased risk of IE (HR 3.4, 95% CI 1.4–8.2). Conclusions Patients with ToF have a substantial risk of IE and the risk is significantly higher compared with the background population. In particular, PVR was associated with an increased risk of IE. With an increasing life-expectancy of these patients, intensified awareness, preventive measures, and surveillance of this patient group are advisable. Figure 1. Cumulative incidence of IE Funding Acknowledgement Type of funding source: None


Author(s):  
Yuji Tominaga ◽  
Masaki Taira ◽  
Takashi Kido ◽  
Tomomitsu Kanaya ◽  
Kanta Araki ◽  
...  

Abstract OBJECTIVES The clinical significance of persistent end-diastolic forward flow (EDFF) after pulmonary valve replacement (PVR) remains unclear in patients with repaired tetralogy of Fallot. This study aimed to identify the characteristics of these patients and the impact of persistent EDFF on outcomes. METHODS Of 46 consecutive patients who underwent PVR for moderate to severe pulmonary regurgitation between 2003 and 2019, 23 (50%) did not show EDFF before PVR [group (−)]. In the remaining 23 patients with EDFF before PVR, EDFF was diminished after PVR in 13 (28%) [group (+, −)] and persisted in 10 (22%) [group (+, +)]. The following variables were compared between these 3 groups: (i) preoperative right ventricular (RV) and right atrial volumes measured by magnetic resonance imaging, haemodynamic parameters measured by cardiac catheterization and the degree of RV myocardial fibrosis measured by RV biopsy obtained at PVR and (ii) the post-PVR course, development of atrial arrhythmia and need for intervention. RESULTS A high RV end-diastolic pressure, a greater right atrial volume index and a greater RV end-systolic volume index before PVR and a high degree of RV fibrosis were significantly associated with persistent EDFF 1 year after PVR. Persistent EDFF was a significant risk factor for postoperative atrial tachyarrhythmia, and catheter ablation and pacemaker implantation were required more frequently in these patients. CONCLUSIONS Persistent EDFF after PVR could predict a worse prognosis, especially an increased risk of arrhythmia. Close follow-up is required in patients with persistent EDFF for early detection of arrhythmia and prompt reintervention if necessary. Clinical trial registration number Institutional review board of Osaka University Hospital, number 16105


Author(s):  
Lucia Cocomello ◽  
Shubhra Sinha ◽  
Maria Cecilia Gonzalez Corcia ◽  
Mai Baquedano ◽  
Umberto Benedetto ◽  
...  

Author(s):  
Simone Ghiselli ◽  
Cristina Carro ◽  
Nicola Uricchio ◽  
Giuseppe Annoni ◽  
Stefano M Marianeschi

Abstract OBJECTIVES Chronic pulmonary valve (PV) regurgitation is a common late sequela after repair of congenital heart diseases like tetralogy of Fallot or pulmonary stenosis, leading to right ventricular dilatation and failure and increased late morbidity and mortality. Timely reoperation may lead to a complete right ventricular recovery. An injectable PV allows pulmonary valve replacement, with or without cardiopulmonary bypass, under direct observation, thereby minimizing the impact of surgery on cardiac function. The aim of this study was to evaluate the feasibility and mid- to long-term clinical outcomes with this device. METHODS From April 2007 to October 2019, a total of 85 symptomatic patients with severe pulmonary regurgitation or pulmonary stenosis underwent pulmonary valve replacement with an injectable stented pulmonary prosthesis. Data were collected from the international proctoring registry. Mean patient age was 26.7 years. The underlying diagnosis was repaired tetralogy of Fallot in 69.4% patients; moderate or severe pulmonary regurgitation was present in 72.9%. All patients had echocardiographic scans before the operation and during the follow-up period. A total of 54.1% patients also had preoperative/postoperative cardiac magnetic resonance imaging (MRI) or catheterization; 25.9% had off-pump implants. In 53% patients, pulmonary valve replacement was associated with the repair of other cardiac defects. RESULTS Minor postoperative complications were observed in 10.8% patients. The overall mortality rate was 2.3%; mortality after valve replacement was linked to a severe cardiac insufficiency and it was not related to a prosthesis failure; 1 prosthesis was explanted from 1 patient because of endocarditis, and 6% of patients developed PV stenosis; minor complications occurred in 4.8%. The mean follow-up period was 4.8 years (2 months–12.7 years); 42% of the patients were followed for more than 5 years. Follow-up echocardiography and cardiac MRI showed a significant reduction in RV size and low gradients across the PV. CONCLUSIONS An injectable PV may be implanted without cardiopulmonary bypass and in a hybrid operating theatre with minimal surgical impact. The bioprosthesis, available up to large sizes, has a low profile, laminar flow and no risk of coronary artery compression. Incidence of endocarditis is rare. The lack of a suture ring permits the implant of a relatively larger prosthesis, thereby avoiding a right ventricular outflow tract obstruction. This device permits future percutaneous valve-in-valve procedures, if needed. Results concerning durability are encouraging, and mid- to long-term haemodynamic performance is excellent.


2003 ◽  
Vol 76 (4) ◽  
pp. 1066-1071 ◽  
Author(s):  
Kenneth G Warner ◽  
Patrick K.H O’Brien ◽  
Jonathan Rhodes ◽  
Avnit Kaur ◽  
Davida A Robinson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document