RP-HPLC method for simultaneous estimation of Rosuvastatin and Ezetimibe from their combination tablet dosage form

2013 ◽  
Vol 4 (4) ◽  
pp. 205-209 ◽  
Author(s):  
Mohammed Ishaq Beludari ◽  
Karanam Vanitha Prakash ◽  
Ghanta Krishna Mohan
Author(s):  
Nikita Shaileshbhai Patel ◽  
Bhavesh Hirabhai Patel

A rapid, precise, accurate, specific and simple stability indicating RP-HPLC method was developed for simultaneous estimation of Dapagliflozin Propanediol (DAPA) and Metformin Hydrochloride (MET) in its tablet dosage form. Method was performed on a column C8 Thermoquest, hypersil division of dimension 250 mm × 4.60 mm having particle size 5 micron. The mobile phase used in the method was 10 mM Ammonium Acetate buffer (pH- 4), Methanol and Acetonitrile in proportion of 30:65:05 respectively. The drug was subjected to acid and alkali hydrolysis, oxidation, photolysis and heat as stress conditions. The method was validated for specificity, linearity, range, precision, accuracy, robustness, LOD, LOQ and system suitability. The flow rate was maintained at 0.8 ml/ min and effluent was monitored at 227 nm. The retention time were observed 5.988 min and 4.661 min for DAPA and MET respectively.  The standard curve was found linear over range of 60-140 μg/ml for DAPA and 300-700 μg/ml for MET with correlation coefficient of 0.9996 for DAPA and 0.9994 for MET. The limit of Detection (LOD) of this method was 1.121 μg/ml for DAPA and 6.162 μg/ml for MET. The limit of Quantitation (LOQ) of this method was 3.396 μg/ml for DAPA and 18.674 μg/ml for MET.  The percentage recovery was found to be in the range of 98-102% at three different levels of a standard addition. The precision (repeatability, intra-day and inter-day) of the method was within the limit (RSD<2%). Degradation products produced because of stress studies did not interfere with the detection of DAPA and MET and the assay can thus be considered stability-indicating. Combination tablet was successfully analysed using the developed method.


2012 ◽  
Vol 24 (1) ◽  
pp. 15-22 ◽  
Author(s):  
P. B. Deshpande ◽  
S. V. Gandhi ◽  
N. V. Gaikwad ◽  
K. S. Khandagle

2012 ◽  
Vol 2 (5) ◽  
Author(s):  
Kumaraswamy Gandla ◽  
JMR Kumar ◽  
JVLN Sheshagiri Rao ◽  
M Lakshmi Surekha

INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (06) ◽  
pp. 51-61
Author(s):  
J. G Modi ◽  
◽  
J. K. Patel

A novel, simple, rapid, and highly selective stability indicating RP-HPLC method was developed and validated for simultaneous estimation of azilsartan medoxomil (AZL) and amlodipine besylate HCl (AMLO) in tablet dosage form having strength of 20 mg and 2.5 mg, respectively. The effective chromatographic separation was achieved on a Phenomenex luna ODS C18 (15 cm X 4.6 mm internal diameter, 3.5 μm Particle size) with a mobile phase composed of phosphate buffer (pH-2.5) adjusted with ortho phosphoric acid : acetonitrile in the ratio of 60:40 v/v. The mobile phase was pumped using an isocratic HPLC system at a flow rate of 0.7 mL/min with injection volume 20μl and quantification of the analytes was done at detection wavelength 254 nm. The retention times were found to be 5.918 min and 14.901 min for AMLO and AZL, respectively. The proposed HPLC method was validated with respect to linearity, ranges, precision, accuracy, specificity, robustness, LOD, and LOQ as per ICH Q2 (R1) guideline. Calibration plots were linear over the concentration range of 75-125 µg/mL and 600-1000 µg/mL with correlation coefficients 0.9966 and 0.9948 for AMLO and AZL, respectively. Forced degradation studies were performed using hydrolysis, oxidation, photolytic, and thermal degradation conditions with good resolution between the degradants and analytes. Degradation products resulting from the stress studies did not interfere with the detection of AMLO and AZL, thus the proposed method is sensitive and stability-indicating. The validated HPLC method was successfully applied to the analysis of AMLO and AZL in tablet dosage form.


Sign in / Sign up