Investigation of the low-frequency stray current induced corrosion on reinforced concrete infrastructure in high-speed rail transit power supply system

Author(s):  
Peng Han ◽  
Guofu Qiao ◽  
Bingbing Guo ◽  
Dongsheng Li ◽  
Jinping Ou
Energies ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 253
Author(s):  
Si Wu ◽  
Mingli Wu ◽  
Yi Wang

The existing problems of the traction power-supply system (i.e., the existence of the neutral section and the power quality problems) limit the development of railways, especially high-speed railways, which are developing rapidly worldwide. The existence of the neutral section leads to the speed loss and traction loss as well as mechanical failures, all of which threaten the fast and safe operation of the train and the system. Meanwhile, the power quality problems (e.g., the negative sequence current, the reactive power, and the harmonic) can bring a series of problems that cannot be ignored on the three-phase grid side. In response, many researchers have proposed co-phase power-supply schemes to solve these two problems simultaneously. Given that the auto-transformer (AT) power-supply mode has become the main power-supply mode for the high-speed railway traction power-supply system, it has a bright future following the rapid development of the high-speed railway. In addition, there is no co-phase power-supply scheme designed for AT power-supply mode in the existing schemes. Therefore, the main contribution of this paper is to propose a specifically designed power-supply mode more suitable for the AT, as well as to establish the control systems for the rectifier side and the inverter side. In addition, for the proposed scheme, the operation principle is analyzed, the mathematical model is built, and the control system is created, and its functionality is verified by simulation, and its advantages are compared and summarized finally. The result proves that it can meet functional requirements. At the same time, compared with the existing co-phase power-supply scheme, it saves an auto-transformer in terms of topology, reduces the current stress by 10.9% in terms of the current stress of the switching device, and reduces the power loss by 0.25% in terms of the entire system power loss, which will result in a larger amount of electricity being saved. All of this makes it a more suitable co-phase power-supply scheme for the AT power-supply mode.


2015 ◽  
Vol 35 (3) ◽  
pp. 63-70 ◽  
Author(s):  
Viktor G. Sychenko ◽  
Dmitry O. Bosiy ◽  
Eugene M. Kosarev

Purpose of the work is improved approaches to ensure the required quality parameters of voltage in the traction network based on modern technologies and equipment in the application of power distribution system. Actuality. The introduction of high-speed traffic, increase weight standards Train necessitates increasing the carrying capacity of railways. Often the carrying capacity of existing sections electrified at 3.0 kV DC power supply unit limits. Such limitations include voltage decrease on the electric current collector below the allowable value for the normal operation of 2700 (2900 for high-speed V) and heating the contact wires, thereby losing their mechanical strength. Existing power supply system of RS, which have considerable installed traction substations, can not provide the required level of power density traction network for high-speed movement within 1.5 - 2 MW / km and, respectively, the required voltage quality. At the same time, the daily loading of a powerful traction substations in providing intensive schedule of trains does not exceed 20-25%, while the energy loss in traction network peak load increases and reaches 10-15% of the energy consumed. Thus, the existing system of power traction networks is not sufficiently effective and economical, even with the application of existing methods to strengthen them. In our view, the main limiting factor for a given quality of voltage in the traction network is the use of centralized power. From this, the development of measures to improve the quality of voltage in the traction network in the implementation of high-speed traffic in a growing scarcity of energy resources is an urgent task. Scientific novelty. Using distributed power supply system with adjustable supply points combined into intelligent power supply, which enables adaptive change the characteristics of the transfer, conversion and consumption and optimize the mode of functioning of the traction power supply is suggested for improving the quality of voltage in the traction network in the implementation of high-speed and heavy traffic. Practical significance. Improving the quality of voltage in the traction network by using the proposed circuit design traction power supply will ensure the desired mode voltage and power characteristics of the traction network in the implementation of high-speed and heavy traffic while reducing electricity losses by 20-30%.


Sign in / Sign up

Export Citation Format

Share Document