Short-circuit modeling of three-phase 4-wire unbalanced networks in presence of single-phase photovoltaic systems

Author(s):  
Antonio Bracale ◽  
P. Caramia ◽  
P. De Falco ◽  
A.R. Di Fazio ◽  
P. Varilone
2012 ◽  
Vol 10 (6) ◽  
pp. 2241-2248
Author(s):  
Marcel Chuma Cerbantes ◽  
Waldemar Pereira Mathias ◽  
Jose Roberto Sanches Mantovani

2014 ◽  
Vol 521 ◽  
pp. 288-291
Author(s):  
Yu Sheng Quan ◽  
Xin Zhao ◽  
Hua Gui Chen ◽  
En Ze Zhou

Based on the method of symmetrical components of D, 11 and Y, o distribution transformer coupling two different effects of different magnetic circuit coupled to the three-phase system with a system-generated analysis and comparison. Analysis of the difference between the two groups of different connections on the transformer structure. Described in the single-phase short circuit fault clearing, 3n harmonic current suppression and affordability aspects of single-phase unbalanced load, D, ll coupling transformers are significantly better than Y,0 coupling transformer. This has necessarily important for the study of energy loss reduction.


2014 ◽  
Vol 875-877 ◽  
pp. 1923-1928 ◽  
Author(s):  
Surya Hardi ◽  
Ismail Daut ◽  
Ismail Rohana ◽  
Muhd Hafizi

Voltage sags and interruption are one of most important of power quality problems. They can influence performance of equipment such as induction motors. They are generally caused by short circuit faults in transmission and distribution systems which propagate in entire of power systems. When their appear at a motor terminal, its effects are the speed and the torque will decrease to a level lower than values of the normal and even the motor become stall if magnitude of the voltage sags and duration exceed certain limit. The voltage can return to nominal voltage after end of the voltage sag and interruption. The motor will experience re-acceleration to normal condition is accompanied by large inrush current. A study on induction motors was carried out to confirm these effects. Single-phase and three-phase of small induction motors were used for investigating the effects caused by symmetrical voltage sags and interruption through experimental and simulation.


2010 ◽  
Vol 34-35 ◽  
pp. 1609-1613
Author(s):  
Yong Jian Li

Because of the extensive application of autotransformer in 500 kV power grid, the value of single-phase short-circuit current is generally greater than that of three-phase short-circuit current, or even greater than the maximum rated through current of the breaker. In order to reduce single-phase short-circuit current and avoid implement of bus split, this paper proposes to install small reactors on neutral points of 500 kV autotransformers. By analyzing and calculating the effect on short-circuit current limitation, the most suitable impedance value of small reactor is proposed. In addition,the overvoltage of the neutral point and insulation coordination are particularly discussed.


Author(s):  
S. N. Mahato ◽  
M. P. Sharma ◽  
S. P. Singh

This paper presents the steady-state and transient behavior of a single-phase self-excited induction generator (SEIG) using a three-phase machine with one shunt and one series excitation capacitors for resistive and inductive loads. The generation scheme consists of one three-phase delta connected induction machine and two capacitors - one connected in parallel with one winding and the other in series with a single-phase load. The dynamic model of the system has been developed as a hybrid model considering the stator phase currents in abc reference frame and the rotor currents in stationary d-q axes reference frame as state variables. The simulated and experimental results are presented for different dynamic conditions such as initiation of self-excitation, load perturbation and short-circuit. The simulated results of the steady-state analysis have been compared with the transient and experimental results and a close agreement between them indicates the accuracy and effectiveness of the approach.


Author(s):  
Deni Almanda ◽  
Juniyanto Juniyanto

Pada saat terjadi gangguan hubung singkat di saluran transmisi Gardu Induk Plumpang, rele jarak berfungsi sebagai proteksi utama. Penelitian ini bertujuan untuk mengetahui pengaruh kompensasi impedansi urutan nol (kzn) terhadap kehandalan sistem proteksi rele jarak (distance relay) pada penghantar harapan indah di Gardu Induk Plumpang. Setting rele jarak yang didapatkan dari PT PLN (Persero) UPT Pulogadung disimulasikan menggunakan alat uji Omicron. Hasil simulasi gangguan hubung singkat satu fasa, gangguan hubung singkat dua fasa, dan gangguan hubung singkat tiga fasa menggunakan setting lama Z1 = 2.58 Ω, Z2 = 3.87 Ω, dan Z3 = 7.30 Ω, kZn = 0.93 Ω < -0.4° rele jarak tidak bekerja selektif, maka dilakukan resetting. Hasil resetting rele jarak yaitu Z1 = 2.58 Ω, Z2 = 3.87 Ω, dan Z3 = 7.30 Ω, kZn = 0.68 Ω < -0.6°. Setelah dilakukan resetting dan disimulasikan gangguan hubung singkat satu fasa, gangguan hubung singkat dua fasa, dan gangguan hubung singkat tiga fasa, rele jarak bekerja secara handal. Kesimpulannya kZn dapat mempengaruhi kehandalan sistem proteksi rele jarak pada penghantar harapan indah di Gardu Induk Plumpang.In the event of a short circuit in the transmission line of the Plumpang Substation, the distance relay serves as the main protection. This study aims to determine the effect of zero sequence impedance compensation (kzn) on the reliability of the distance relay protection system at the Harapan Indah conductor at the Plumpang Substation. The distance relay setting obtained from PT PLN (Persero) UPT Pulogadung was simulated using the Omicron test tool. Simulation results of single phase short circuit, two phase short circuit, and three phase short circuit using the old setting Z1 = 2.58 Ω, Z2 = 3.87 Ω, and Z3 = 7.30 Ω, kZn = 0.93 < -0.4° relay distance does not works selectively, then resetting is done. The results of resetting the distance relay are Z1 = 2.58 Ω, Z2 = 3.87 Ω, and Z3 = 7.30 Ω, kZn = 0.68 < -0.6°. After resetting and simulating single-phase short circuit, two phase short circuit, and three phase short circuit fault, the distance relay works reliably. In conclusion, kZn can affect the reliability of the distance relay protection system on the beautiful hope conductor at the Plumpang Substation.