Two-phase flow condensation pressure drop of R14 in a horizontal tube: Experimental investigation and correlation development

Author(s):  
Qinglu Song ◽  
Gaofei Chen ◽  
Hao Guo ◽  
Jun Shen ◽  
Maoqiong Gong
2016 ◽  
Vol 78 (8-4) ◽  
Author(s):  
Agus Sunjarianto Pamitran ◽  
Sentot Novianto ◽  
Normah Mohd-Ghazali ◽  
Nasruddin Nasruddin ◽  
Raldi Koestoer

Two-phase flow boiling pressure drop experiment was conducted to observe its characteristics and to develop a new correlation of void fraction based on the separated model. Investigation is completed on the natural refrigerant R-290 (propane) in a horizontal circular tube with a 7.6 mm inner diameter under experimental conditions of 3.7 to 9.6 °C saturation temperature, 10 to 25 kW/m2 heat flux, and 185 to 445 kg/m2s mass flux. The present experimental data was used to obtain the calculated void fraction which then was compared to the predicted void fraction with 31 existing correlations. A new void fraction correlation for predicting two-phase flow boiling pressure drop, as a function of Reynolds numbers, was proposed. The measured pressure drop was compared to the predicted pressure drop with some existing pressure drop models that use the newly developed void fraction model. The homogeneous model of void fraction showed the best prediction with 2% deviation


2019 ◽  
Vol 17 (72) ◽  
pp. 101-109
Author(s):  
Muhsen Koli Nahi

The aim of this study is to discover the deviation of two phase flow correlations. A comparsion was made between the expermital values of two-phase flow pressure drops data were obtained experimentally by Al-Jumaily (1999) by using air-water mixture in a horizontal tube of (132 mm) nominal diameter and a test section of (32 m) long at pressure and temperature close to atmospheric and those predicted by three correlations well-used in the literature, which show that the homogeneous model was the best


2019 ◽  
Vol 142 (2) ◽  
Author(s):  
Ammar Zeghloul ◽  
Hiba Bouyahiaoui ◽  
Abdelwahid Azzi ◽  
Abbas H. Hasan ◽  
Abdelsalam Al-sarkhi

Abstract This paper presents an experimental investigation of the pressure drop (DP) through valves in vertical upward flows. Experiments were carried out using a 1¼″ (DN 32) ball and gate valve. Five opening areas have been investigated from fully open to the nearly fully closed valve, using air with a superficial velocity of 0–3.5 m/s and water 0.05–0.91 m/s. These ranges cover single-phase and the bubbly, slug and churn two-phase flow regimes. It was found that for the single-phase flow experiments, the valve coefficient increases with the valve opening and is the same, in both valves, for the openings smaller than 40%. The single-phase pressure drop increases with the liquid flowrate and decreases with the opening area. The two-phase flow pressure drop was found considerably increased by reducing the opening area for both valves. It reaches its maximum values at 20% opening for the ball valve and 19% opening for the gate valve. It was also inferred that at fully opening condition, the two-phase flow multiplier, for both valves, has been found close to unity for most of the tested flow conditions. For 40 and 20% valve openings the two-phase multiplier decreases in the power-law with liquid holdup for the studied flow conditions. Models proposed originally for evaluating the pressure drop through an orifice in single-phase and two-phase flows were also applied and assessed in the present experimental data.


2021 ◽  
Author(s):  
Swati Jadhav ◽  
Manojkumar Hambarde ◽  
Ramakant Shrivastava ◽  
Gopal Nandan