Biomechanical in-vitro study concerning the stability of customized CAD/CAM mandibular reconstruction plates. Comparison of additively and subtractively manufactured as well as hand-bended plates

2019 ◽  
Vol 48 ◽  
pp. 150-151
Author(s):  
Frank Wilde ◽  
Robin Kasper ◽  
Andreas Sakkas ◽  
Sebastian Pietzka ◽  
Karsten Winter ◽  
...  
2021 ◽  
Vol 11 (2) ◽  
pp. 857
Author(s):  
Keunbada Son ◽  
Kyu-Bok Lee

The purpose of this in vitro study was to evaluate marginal and internal fits of ceramic crowns fabricated with chairside computer-aided design and manufacturing (CAD/CAM) systems. An experimental model based on ISO 12836:2015 was digitally scanned with different intraoral scanners (Omnicam (CEREC), EZIS PO (DDS), and CS3500 (Carestream)). Ceramic crowns were fabricated using the CAD/CAM process recommended by each system (CEREC, EZIS, and Carestream systems; N = 15). The 3-dimensional (3D) marginal and internal fit of each ceramic crown was measured using a 3D inspection software (Geomagic control X). Differences among the systems and various measurements were evaluated using the Kruskal–Wallis test. Statistically significant differences were validated using pairwise comparisons (α = 0.05). Occlusal gaps in the CEREC, EZIS, and Carestream groups were 113.0, 161.3, and 438.2 µm, respectively (p < 0.001). The axial gaps were 83.4, 78.0, and 107.9 µm, respectively. The marginal gaps were 77.8, 99.3, and 60.6 µm, respectively, and the whole gaps were 85.9, 107.3, and 214.0 µm, respectively. Significant differences were observed with the EZIS system compared with the other two systems in terms of the marginal gap sizes. The CEREC system showed no significant differences among the four measured regions. However, the EZIS and Carestream systems did show a statistically significant difference (p < 0.05). All three systems were judged to be capable of fabricating clinically acceptable prostheses, because the marginal gap, which is the most important factor in the marginal fit of prostheses, was recorded to be below 100 µm in all three systems.


2021 ◽  
Vol 24 (6) ◽  
pp. 828
Author(s):  
A Robaian ◽  
A Maawadh ◽  
ZI Alghomlas ◽  
AM Alqahtani ◽  
TA Alothman ◽  
...  

2020 ◽  
pp. 194338752095268
Author(s):  
Robin Kasper ◽  
Karsten Winter ◽  
Sebastian Pietzka ◽  
Alexander Schramm ◽  
Frank Wilde

Study Design: An experimental in vitro study. Objective: Plate fractures are a recurrent problem in alloplastic mandibular reconstruction. Hypothetically it can be assumed that computer-aided design (CAD)/computer-aided manufacturing (CAM) reconstruction plates have a higher stability than conventional hand-bent plates. The aim of the study was to compare additive and subtractive fabricated CAD/CAM mandibular reconstruction plates as well as conventional plates with regard to their biomechanical properties. Methods: In a chewing simulator, plates of 2 conventional locking plate systems and 2 CAD/CAM-fabricated plate systems were compared. The plates were loaded in a fatigue test. The maximum number of cycles until plate fracture and the plate stiffness were compared. Results: While all conventional plates fractured at a maximum load between 150 and 210 N (Newton) after a number of cycles between 40 000 and 643 000, none of the CAD/CAM plates broke despite a nearly doubled load of 330 N and 2 million cycles. Both CAD/CAM systems proved to be significantly superior to the hand-bent plates. There was no difference between the 2 CAD/CAM systems. Conclusions: Concerning the risk of plate fracture, patient-specific CAD/CAM reconstruction plates appear to have a significant advantage over conventional hand-bent plates in alloplastic mandibular reconstruction.