The role of bone conduction hearing aids in congenital unilateral hearing loss: A systematic review

Author(s):  
C. Carrie Liu ◽  
Devon Livingstone ◽  
Warren K. Yunker
2017 ◽  
Vol 157 (4) ◽  
pp. 565-571 ◽  
Author(s):  
Swathi Appachi ◽  
Jessica. L. Specht ◽  
Nikhila Raol ◽  
Judith E. C. Lieu ◽  
Michael S. Cohen ◽  
...  

Objective Options for management of unilateral hearing loss (UHL) in children include conventional hearing aids, bone-conduction hearing devices, contralateral routing of signal (CROS) aids, and frequency-modulating (FM) systems. The objective of this study was to systematically review the current literature to characterize auditory outcomes of hearing rehabilitation options in UHL. Data Sources PubMed, EMBASE, Medline, CINAHL, and Cochrane Library were searched from inception to January 2016. Manual searches of bibliographies were also performed. Review Methods Studies analyzing auditory outcomes of hearing amplification in children with UHL were included. Outcome measures included functional and objective auditory results. Two independent reviewers evaluated each abstract and article. Results Of the 249 articles identified, 12 met inclusion criteria. Seven articles solely focused on outcomes with bone-conduction hearing devices. Outcomes favored improved pure-tone averages, speech recognition thresholds, and sound localization in implanted patients. Five studies focused on FM systems, conventional hearing aids, or CROS hearing aids. Limited data are available but suggest a trend toward improvement in speech perception with hearing aids. FM systems were shown to have the most benefit for speech recognition in noise. Studies evaluating CROS hearing aids demonstrated variable outcomes. Conclusions Data evaluating functional and objective auditory measures following hearing amplification in children with UHL are limited. Most studies do suggest improvement in speech perception, speech recognition in noise, and sound localization with a hearing rehabilitation device.


2021 ◽  
Vol 75 (4) ◽  
pp. 1-5
Author(s):  
Joanna Marszał ◽  
Renata Gibasiewicz ◽  
Magdalena Błaszczyk ◽  
Maria Gawlowska ◽  
Wojciech Gawęcki

Introduction: Nowadays, there are many options to treat hearing-impaired patients: tympanoplastic surgery, hearing aids and a wide range of implantable devices. Objective: The aim of this study is to present the mid-term audiological and quality of life benefits after the implantation of the Osia®, a new active piezoelectric bone conduction hearing implant. Material and methods: The state of the tissues in implanted area, as well as audiological and quality of life results were analyzed six, nine and twelve months after implantation in a group of four adult patients with bilateral mixed hearing loss. Results: In all the cases, no postoperative complications were found. One year after surgery the mean audiological gain in FF PTA4 (pure tone average for 0.5, 1, 2, and 4 kHz) was 52.2±3.5 dB in comparison to the unaided situation, the mean speech understanding with Osia® in quiet was 90±8.2% for 50dB SPL, 98.8±2.5% for 65dB SPL and 100±0% for 80dB SPL, and mean speech understanding with Osia® in noise was 37.5%±23.6 for 50dB SPL, 93.8±4.8% for 65dB SPL and 98.8±2.5% for 80dB SPL. There was also an evident improvement in the quality of hearing as well as in the quality of life, measured by the APHAB (Abbreviated Profile of Hearing Aid Benefit) and the SSQ (Speech, Spatial and Qualities of Hearing Scale). Conclusions: The Osia® is an effective treatment option for patients with bilateral mixed hearing loss. The mid-term audiological and quality of life results are excellent, but further observations including bigger groups of patients and a longer follow-up are required.


2020 ◽  
Vol 41 (3) ◽  
pp. 379-385
Author(s):  
Ohad Hilly ◽  
Meirav Sokolov ◽  
Reut Beck Finkel ◽  
Ofir Zavdy ◽  
Rafael Shemesh ◽  
...  

2020 ◽  
Vol 30 (Supplement_2) ◽  
Author(s):  
T Marques ◽  
A Carvalho ◽  
A Miguéis

Abstract Introduction Bone conduction hearing systems can be applied through non-invasive devices, using soft bands that exert pressure on the skin, or they can be surgically implanted (Bone Anchored Hearing Aid - BAHA). However, these bone conduction devices are frequently not well accepted due to the pressure on the head. Therefore, a new non-surgical hearing system was developed not to exert pressure on the skin, the ADHEAR. The bone anchorage in ADHEAR is performed through an adhesive adapter and is indicated for patients with conductive hearing loss and normal inner ear function. Objectives Evaluate the audiological performance with the adhesive bone conduction hearing device (ADHEAR) in a patient with conductive hearing loss. Methodology The study was designed as a prospective single-subject repeated-measure study with the subject serving as his own control. A 29 year old female patient who had a primary surgery due to middle ear cholesteatoma, was adapted with unilateral non-invasive adhesive bone conduction system for the treatment of conductive hearing loss. Air and bone conduction thresholds, word recognition scores (WRS) and speech recognition thresholds (SRT) in quiet and noise were assessed to verify the inclusion criteria of the study. Aided and unaided pure tone audiometry at 0.5, 1, 2 and 4 kHz in free field and speech audiometry in quiet and noise were performed at baseline and after 4 weeks with the ADHEAR. Results The functional gain with the ADHEAR averaged over 0.5, 1, 2, and 4 kHz after 4 weeks of usage of the adhesive hearing system, improved from 55 dB HL to 31dB HL. Speech perception in quiet and noise improved significantly in the aided situation, with SRT in quiet improving from 60 to 35 dB HL, when compared to the unaided condition. Similar results were found in noise. The patient evaluated the ADHEAR system as being useful, and without complaints of skin pressure. There was no adverse skin reaction. Conclusion Hearing performance was significantly better with ADHEAR under all test conditions. Therefore, this transcutaneous hearing system seems to be an excellent alternative for patients who need a hearing solution for conductive hearing loss but for clinical reasons cannot undergo surgery or conventional hearing aids. Furthermore, it preserves skin over the mastoid and reduces the risk of infection. Otherwise it has benefits verified by absence of head pressure and improvement of patient’s quality of life.


2010 ◽  
Vol 21 (04) ◽  
pp. 267-273 ◽  
Author(s):  
Lisa Christensen ◽  
Laura Smith-Olinde ◽  
Jillian Kimberlain ◽  
Gresham T. Richter ◽  
John L. Dornhoffer

Background: Little research exists to demonstrate efficacy and verification measures of the Baha® system versus traditional bone-conduction hearing aids. This study gives statistical data about 10 children who have used traditional bone-conduction hearing aids, Baha coupled to a Softband, and the Baha system implanted. Purpose: The purpose of this study was to compare functional gain at 500, 1000, 2000, and 4000 Hz for infants and children with bilateral conductive hearing loss who were initially fit with traditional bone-conduction devices then progressed to Baha with Softband and finally to unilateral Baha implants. Research Design: Retrospective five-year chart review. Study Sample: 10 children with bilateral conductive hearing loss due to congenital atresia and/or microtia. Participants ranged in age from 6 mo to 16 yr; three were male and seven were female. Two participants were African-American, five Caucasian, and three Hispanic. Intervention: The intervention was the Baha system used in children via a Softband or implanted as compared to traditional bone-conduction hearing aids. Data Collection and Analysis: Single-factor, repeated analyses of variance were run to examine the amount of functional gain delivered by the various devices as well as the threshold measures with each device at each frequency. Results: Participants in this study showed a statistically significant improvement when using the Baha Softband over traditional bone-conduction hearing aids. An implanted Baha has statistically as much gain as a bone-conduction transducer at all frequencies tested. Conclusions: The Baha system is a valid treatment in conductive hearing loss via a Softband or implanted. It statistically outperforms the traditional bone-conduction hearing aids and should be used as a first choice in intervention rather than a last option for inoperable conductive hearing loss.


2016 ◽  
Vol 27 (10) ◽  
pp. 790-804 ◽  
Author(s):  
Melissa J. Polonenko ◽  
Lora Carinci ◽  
Karen A. Gordon ◽  
Blake C. Papsin ◽  
Sharon L. Cushing

Background: Bilateral hearing is important for learning, development, and function in complex everyday environments. Children with conductive and mixed hearing loss (HL) have been treated for years with percutaneous coupling through an abutment, which achieves powerful output, but the implant site is susceptible to skin reactions and trauma. To overcome these complications, transcutaneous magnetic coupling systems were recently introduced. Purpose: The purpose of the study was to evaluate whether the new transcutaneous magnetic coupling is an effective coupling paradigm for bone-conduction hearing aids (BCHAs). We hypothesized that magnetic coupling will (1) have limited adverse events, (2) provide adequate functional gain, (3) improve spatial hearing and aid listening in everyday situations, and (4) provide satisfactory outcomes to children and their families given one normal hearing ear. Research Design: Retrospective analysis of audiological outcomes in a tertiary academic pediatric hospital. Study Sample: Nine children aged 5–17 yr with permanent unilateral conductive HL (UCHL) or mixed HL were implanted with a transcutaneous magnet–retained BCHA. Average hearing thresholds of the better and implanted ears were 12.3 ± 11.5 dB HL and 69.1 ± 11.6 dB HL, respectively, with a 59.4 ± 4.8 dB (mean ± standard deviation) conductive component. Data Collection and Analysis: Data were extracted from audiology charts of the children with permanent UCHL or mixed HL who qualified for a surgically retained BCHA and agreed to the magnetic coupling. Outcomes were collected from the 3- to 9-mo follow-up appointments, and included surgical complications, aided audiometric thresholds with varying magnet strength, speech performance in quiet and noise, and patient-rated benefit and satisfaction using questionnaires. Repeated measures analysis of variance was used to analyze audiometric outcomes, and nonparametric tests were used to evaluate rated benefit and satisfaction. Results: All nine children tolerated the device and only one child had discomfort at the wound site. Similar access to sound was achieved regardless of magnet strength. Speech performance did not significantly improve in quiet or noise conditions with +10 and +5 dB signal-to-noise ratio. Children benefited from spatially separating the noise from the speech signal, regardless of whether the noise was directed to the implanted or better ear. When wearing the BCHA, the children reported satisfaction and significant implant benefit, particularly in background noise, but at the expense of increased aversiveness to sound. Conclusions: Our findings, therefore, indicate that providing a transcutaneous magnetic-coupled BCHA to children who have UCHL or mixed HL provides benefit on some objective measures of bilateral hearing, as well as some subjective benefit in noise and everyday situations.


2015 ◽  
Vol 20 (01) ◽  
pp. 034-038 ◽  
Author(s):  
Maria Mondelli ◽  
Thais Mariano ◽  
Heitor Honório ◽  
Rubens Brito

Introduction Hearing loss is the most common clinical finding in patients with malformation of the external ear canal. Among the possibilities of treatment, there is the adaptation of hearing aids by bone conduction and the adaptation of implantable hearing aids. Objective To assess speech perception with the use of Vibrant Soundbridge (VBS - MED-EL, Innsbruck, Austria) associated with additional amplification in patients with bilateral craniofacial malformation. Method We evaluated 11 patients with bilateral malformation over 12 years with mixed hearing loss or bilateral conductive. They were using the Softband (Oticon Medical, Sweden) and bone conduction hearing aid in the ear opposite the one with the VSB. We performed the evaluation of speech perception using the Hearing in Noise Test. Results Participants were eight men and three women with a mean of 19.5 years. The signal / noise ratio presented significant results in patients fitted with VSB and bone conduction hearing aid. Conclusion The results of speech perception were significantly better with use of VBS combined with bone conduction hearing aids.


Sign in / Sign up

Export Citation Format

Share Document