Falsely high rebound tonometry

Author(s):  
Jade M. Price ◽  
Brooke Saffren ◽  
Qiang Zhang ◽  
Rose A. Hamershock ◽  
James Sharpe ◽  
...  
Keyword(s):  
Ophthalmology ◽  
2008 ◽  
Vol 115 (1) ◽  
pp. 80-84 ◽  
Author(s):  
Wan-sang Chui ◽  
Andrew Lam ◽  
Davie Chen ◽  
Roger Chiu
Keyword(s):  

2021 ◽  
Vol Publish Ahead of Print ◽  
Author(s):  
Laura Morales-Fernandez ◽  
Federico Saenz-Frances ◽  
Pilar Pérez-García ◽  
Julian Garcia-Feijoo ◽  
Sofia Garcia-Saenz ◽  
...  

Ophthalmology ◽  
2019 ◽  
Vol 126 (9) ◽  
pp. 1330-1332 ◽  
Author(s):  
Swathi Vallabh Badakere ◽  
Harsha L. Rao ◽  
Mohammad Hasnat Ali ◽  
Anil K. Mandal ◽  
Nikhil S. Choudhari ◽  
...  

2020 ◽  
Vol 43 (5) ◽  
pp. 503-506
Author(s):  
Corrina P. Azarcon ◽  
Romeo C. dela Cruz

2009 ◽  
Vol 248 (4) ◽  
pp. 585-591 ◽  
Author(s):  
Teresio Avitabile ◽  
Antonio Longo ◽  
Daniela Rocca ◽  
Roberta Amato ◽  
Caterina Gagliano ◽  
...  

Therapy ◽  
2011 ◽  
Vol 8 (5) ◽  
pp. 555-561
Author(s):  
Javier Ruiz-Alcocer ◽  
David Madrid-Costa ◽  
Caridad Pérez-Vives ◽  
Santiago García-Lázaro ◽  
Jorge Jorge

2007 ◽  
Vol 27 (5) ◽  
pp. 506-511 ◽  
Author(s):  
A. Queirós ◽  
J. M. González-Méijome ◽  
P. Fernandes ◽  
J. Jorge ◽  
R. Montés-Micó ◽  
...  

2018 ◽  
Vol 102 (11) ◽  
pp. 1515-1519 ◽  
Author(s):  
Sung Uk Baek ◽  
Ahnul Ha ◽  
Young Kook Kim ◽  
Jin Wook Jeoung ◽  
Ki Ho Park

Background/aimsTo investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)).Methods103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured.ResultsThe mean value of IOP measured by GAT was 13.97±2.80 mm Hg, which was not significantly different from that by RT without LM (13.75±2.44 mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21±2.91 mm Hg; P<0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: −1.5) and RT without LM (mean: −1.2). Among the high IOPs (>20 mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P<0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P<0.001).ConclusionRT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.


Sign in / Sign up

Export Citation Format

Share Document