bland altman plot
Recently Published Documents


TOTAL DOCUMENTS

107
(FIVE YEARS 66)

H-INDEX

11
(FIVE YEARS 3)

2022 ◽  
Author(s):  
Ruo-Yu Zhang ◽  
Wei Wang ◽  
Hui-Jun Zhou ◽  
Jianwei Xuan ◽  
Nan Luo ◽  
...  

Abstract Background: Two EQ-5D-3L (3L) value sets (developed in 2014 and 2018) co-exist in China. The study examined the level of agreement between index scores for all the 243 health states derived from them at both absolute and relative levels and compared the responsiveness of the two indices. Methods: Intraclass correlations coefficient (ICC) and Bland-Altman plot were adopted to assess the degree of agreement between the two indices at the absolute level. Health gains for 29,403 possible transitions between pairs of 3L health states were calculated to assess the agreement at the relative level. Their responsiveness for the transitions was assessed using Cohen effect size.Results:The mean (standard deviation, SD) value was 0.427 (0.206) and 0.649 (0.189) for the 3L2014 and 3L2018 index scores, respectively. Although the ICC value showed good agreement (i.e., 0.896), 88.9% (216/243) of the points were beyond the minimum important difference limit according to the Bland-Altman plot. The mean health gains for the 29,403 health transitions was 0.234 (3L2014 index score) and 0.216 (3L2018 index score). The two indices predicted consistent transitions in 23,720 (80.7%) of 29,403 pairs. For the consistent pairs, Cohen effective size value was 1.05 (3L2014 index score) or 1.06 (3L2018 index score); and the 3L2014 index score only yielded 0.007 more utility gains. However, the results based on the two measures varied substantially according to the direction and magnitude of health change. Conclusion:The 3L2014 and 3L2018 index scores are not interchangeable. The choice between them is likely to influence QALYs estimations.


Computation ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 8
Author(s):  
M. Maithri ◽  
Dhanush G. Ballal ◽  
Santhosh Kumar ◽  
U. Raghavendra ◽  
Anjan Gudigar ◽  
...  

The present study evaluated a newly developed computational tool (CT) to assess the alveolar bone space and the alveolar crest angle and compares it to dentist assessment (GT). The novel tool consisted of a set of processes initiated with image enhancement, points localization, and angle and area calculations. In total, we analyzed 148 sites in 39 radiographic images, and among these, 42 sites were selected and divided into two groups of non-periodontitis and periodontitis. The alveolar space area (ASA) and alveolar crest angle (ACA) were estimated. The agreement between the computer software and the ground truth was analyzed using the Bland–Altman plot. The sensitivity and specificity of the computer tool were measured using the ROC curve. The Bland–Altman plot showed an agreement between the ground truth and the computational tool in all of the parameters assessed. The ROC curve showed 100% sensitivity and 100% specificity for 12.67 mm of the alveolar space area. The maximum percentage of sensitivity and specificity were 80.95% for 13.63 degrees of the alveolar crest angle. Computer tool assessment provides accurate disease severity and treatment monitoring for evaluating the alveolar space area (ASA) and the alveolar crest angle (ACA).


2021 ◽  
Vol 16 (2) ◽  
pp. 161-167
Author(s):  
Zeynep Eylül Ercan ◽  

Central corneal thickness (CCT) measurements are important for diagnosis, treatment, and surgery planning in ophthalmology. The purpose of this study was to see whether CCT measurements taken with Tono-pachymeter and Scheimpflug- Placido Topography had any significant differences. Tono-pachymeter and topography CCT measurements were taken (n=400). Inter-measurement agreement between them was determined using Bland-Altman Plot analysis. Age groups were also formed as group 1 (aged 18-50 years, 94 males, 106 females) and group 2 (age >51 years, 100 males, 100 females). Mean CCTs measured by Tonopachymeter and topography were 563.77 +±26.43 and 560.88 + 26.341 microns. Bland-Altman Plot analysis showed in total, 13 were above the upper limit and 5 were under the minimum limit of agreement with regression analysis showing no significant relationships (p=0.213). Group 1 had 7 above and 2 below from the limits of agreement. Group two had 9 above and 2 below from the limits of agreement. Both groups showed insignificant differences between devices (p=0.07 and p=0.86). Tono-pachymeter and Scheimpflug-Placido Topography give reliable CCT results within each other. However, since the limit of agreement ranges can still affect one-to-one patient evaluations, we recommend clinics that use these devices to not interchange measurements in practice.


2021 ◽  
Vol 12 ◽  
Author(s):  
Seung Hyun Min ◽  
Jiawei Zhou

R, a programming language, is an attractive tool for data visualization because it is free and open source. However, learning R can be intimidating and cumbersome for many. In this report, we introduce an R package called “smplot” for easy and elegant data visualization. The R package “smplot” generates graphs with defaults that are visually pleasing and informative. Although it requires basic knowledge of R and ggplot2, it significantly simplifies the process of plotting a bar graph, a violin plot, a correlation plot, a slope chart, a Bland-Altman plot and a raincloud plot. The aesthetics of the plots generated from the package are elegant, highly customisable and adhere to important practices of data visualization. The functions from smplot can be used in a modular fashion, thereby allowing the user to further customise the aesthetics. The smplot package is open source under the MIT license and available on Github (https://github.com/smin95/smplot), where updates will be posted. All the example figures in this report are reproducible and the codes and data are provided for the reader in a separate online guide (https://smin95.github.io/dataviz/).


2021 ◽  
Vol 8 ◽  
Author(s):  
Weicong Lu ◽  
Rongyuan Ji ◽  
Wenzhi Ding ◽  
Yuyin Tian ◽  
Keli Long ◽  
...  

Purpose: To evaluate the repeatability of a multispectral-based refractor in central and peripheral refraction measurement, and to assess the agreement of such measurements with objective refraction (OR) and subjective refraction (SR) in patients with myopia.Methods: A total of 60 subjects were recruited in this prospective research. Patients were divided into three groups according to the refractive error. Next, the central and peripheral refraction parameters were measured using multispectral refractive tomography (MRT) before and after cycloplegia. In addition, OR and SR measurements were also performed. The intraobserver repeatability was analyzed using within-subject standard deviation (Sw), test–retest repeatability (TRT), and intraclass correlation coefficient (ICC). Agreement was evaluated using Bland-Altman plot and 95% limits of agreement (LoA).Results: The ICC value of central and peripheral refraction were all higher than 0.97 with or without cycloplegia. The peripheral refraction in the nasal, temporal, superior, and inferior quadrants was slightly worse than other parameters, with the largest error interval being 1.43 D. The 95% LoA of the central refraction and OR or SR ranged from −0.89 to 0.88 D and −1.24 to 1.16 D without cycloplegia, respectively, and from −0.80 to 0.42 D and −1.39 to −0.84 D under cycloplegia, respectively.Conclusions: The novel multispectral refraction topography demonstrated good repeatability in central and peripheral refraction. However, the refraction in the nasal, temporal, superior, and inferior quadrants were not as good as that of central and circle peripheral refraction.


Author(s):  
Walter Luis Teixeira ALVES ◽  
Iza de FARIA-FORTINI ◽  
Ana Carolina Daher Ribas GALVÃO ◽  
Francisco Eduardo Costa CARDOSO ◽  
Paula Luciana SCALZO

ABSTRACT Background: Culturally adapted measures to assess the performance of activities of daily living (ADL) in individuals with Parkinson’s disease (PD) are limited in Brazil. Objective: To adapt the ADL Questionnaire to the Brazilian culture and to analyze its reproducibility in individuals with PD. Methods: The ADL Questionnaire was translated and cross-culturally adapted to Brazilian Portuguese language. Reproducibility was analyzed using test-retest reliability and agreement values. The test-retest reliability of the individual items and total scores were calculated. The limits of agreement were verified using the Bland-Altman plot. The standard error of measurement (SEM) and the minimum detectable change (MDC) were calculated. Patients who were classified on a score of 1–4 on the modified Hoehn and Yahr scale were eligible. Results: No divergence was identified between the original and the adapted version, which demonstrated adequate semantic and conceptual equivalence. The Bland-Altman plot showed no systematic changes in the mean test-retest scores. The intraclass correlation coefficient (ICC) was 0.98 (95% confidence interval [95%CI] 0.93–0.99), and all individual items showed good levels of reliability (>0.60). The SEM (SEM%) and MDC (MDC%) values were 3.0 (6.75%) and 8.2 (18.7%), respectively. These values are within the recommended values. Conclusions: The ADL-Brazil Questionnaire is a reliable instrument to be used for clinical and research purposes to assess self-perceptions of ADL performance in individuals with PD.


Author(s):  
Nils-Hendrik Benning ◽  
Petra Knaup ◽  
Rüdiger Rupp

Abstract Background The level of physical activity (PA) of people with spinal cord injury (SCI) has an impact on long-term complications. Currently, PA is mostly assessed by interviews. Wearable activity trackers are promising tools to objectively measure PA under everyday conditions. The only off-the-shelf, wearable activity tracker with specific measures for wheelchair users is the Apple Watch. Objectives This study analyzes the measurement performance of Apple Watch Series 4 for wheelchair users and compares it with an earlier generation of the device. Methods Fifteen participants with subacute SCI during their first in-patient phase followed a test course using their wheelchair. The number of wheelchair pushes was counted manually by visual inspection and with the Apple Watch. Difference between the Apple Watch and the rater was analyzed with mean absolute percent error (MAPE) and a Bland–Altman plot. To compare the measurement error of Series 4 and an older generation of the device a t-test was calculated using data for Series 1 from a former study. Results The average of differences was 12.33 pushes (n = 15), whereas participants pushed the wheelchair 138.4 times on average (range 86–271 pushes). The range of difference and the Bland–Altman plot indicate an overestimation by Apple Watch. MAPE is 9.20% and the t-test, testing for an effect of Series 4 on the percentage of error compared with Series 1, was significant with p < 0.05. Conclusion Series 4 shows a significant improvement in measurement performance compared with Series 1. Series 4 can be considered as a promising data source to capture the number of wheelchair pushes on even grounds. Future research should analyze the long-term measurement performance during everyday conditions of Series 4.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hiroshi Matsuda ◽  
Tensho Yamao ◽  
Mitsuru Shakado ◽  
Yoko Shigemoto ◽  
Kyoji Okita ◽  
...  

Abstract Background Centiloid (CL) scaling has become a standardized quantitative measure in amyloid PET because it facilitates the direct comparison of results across institutions, even when different analytical methods or tracers are used. Standard volumes of interest must be used to calculate the CL scale after the anatomic standardization of amyloid PET images using coregistered MRI; if the MRI is unavailable, the CL scale cannot be accurately calculated. This study sought to determine the substitutability of low-dose CT, which is used to correct PET attenuation in PET/CT equipment, by evaluating the measurement accuracy when low-dose CT is used as an alternative to MRI in the calculation of the CL scale. Amyloid PET images obtained using 18F-flutemetamol from 24 patients with possible or probable Alzheimer’s disease were processed to calculate the CL scale using 3D T1-weighted MRI and low-dose CT of PET/CT. CLMRI and CLCT were, respectively, defined as the use of MRI and CT for anatomic standardization and compared. Regional differences in the CT-based and MRI-based standardized anatomic images were also investigated. Trial registration: Japan Registry of Clinical Trials, jRCTs031180321 (registered 18 March 2019, https://jrct.niph.go.jp/latest-detail/jRCTs031180321). Results A Bland–Altman plot showed that CLCT was slightly but significantly underestimated (mean ± standard deviation, − 1.7 ± 2.4; p < 0.002) compared with CLMRI. The 95% limits of agreement ranged from − 2.8 to − 0.7. Pearson correlation analysis showed a highly significant correlation of r = 0.998 between CLCT and CLMRI (p < 0.001). The linear regression equation was CLMRI = 1.027 × CLCT + 0.762. In a Bland–Altman plot, Spearman correlation analysis did not identify a significant association between the difference in CLMRI versus CLCT and CL load (ρ =  − 0.389, p = 0.060). This slight underestimation of CLCT may derive from slightly higher uptake when the cerebellum is used as a reference area in CT-based anatomically standardized PET images versus MRI-based images. Conclusions Low-dose CT of PET/CT can substitute for MRI in the anatomic standardization used to calculate the CL scale from amyloid PET, although a slight underestimation occurs.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Yu Lan ◽  
Nan Li ◽  
Qing Song ◽  
Ming-bo Zhang ◽  
Yu-kun Luo ◽  
...  

Abstract Background To evaluate the correlation and agreement between superb micro-vascular imaging (SMI) mode and the contrast-enhanced ultrasound (CEUS) mode for the ablative completeness and the volumes of ablation lesions to determine the clinical application value of SMI in follow-up after radiofrequency ablation. Methods From April 2020 to June 2020, two radiologists used SMI and CEUS mode to measure the volume of the ablation lesion. We use intra-class correlation coefficient (ICC), scatter plots and Bland–Altman plots to evaluate the correlation and agreement of the two techniques. In addition, intra- and inter-observer reliability in volume measurement of ablation lesions with SMI mode was assessed. Results SMI mode and CEUS mode have good agreement in the evaluation of ablative completeness. The ICC was 0.876 and 0.928 of reader A and reader B between SMI mode and CEUS mode in terms of ablation lesions volume measurement. There was a strong correlation between the two modes in both reader A and reader B (rA = 0.808; rB = 0.882). The ICC was 0.836 for the inter-observer reliability of SMI technique. The scatter plot showed a good linear relation (r = 0.715). In the Bland–Altman plot, 4.35% (1/23) of the points was outside the 95% limits of agreement. The ICC was 0.965 for the intra-observer reliability of SMI technique, the scatter plot also showed a strong linear correlation (r = 0.965). In the Bland–Altman plot, 8.70% (2/23) of the points was outside the 95% limits of agreement. Conclusions SMI and CEUS have good agreement and correlation in the ablation volume measurement. SMI technology is expected to be applied as an alternative to CEUS in the clinical follow-up of ablation lesions.