scholarly journals Clinical Bioprosthetic Heart Valve Thrombosis After Transcatheter Aortic Valve Replacement

2017 ◽  
Vol 10 (7) ◽  
pp. 686-697 ◽  
Author(s):  
John Jose ◽  
Dmitriy S. Sulimov ◽  
Mohamed El-Mawardy ◽  
Takao Sato ◽  
Abdelhakim Allali ◽  
...  
Diagnostics ◽  
2020 ◽  
Vol 10 (4) ◽  
pp. 183 ◽  
Author(s):  
Francesco Nappi ◽  
Laura Mazzocchi ◽  
Irina Timofeva ◽  
Laurent Macron ◽  
Simone Morganti ◽  
...  

Background: Transcatheter aortic valve replacement has proved its safety and effectiveness in intermediate- to high-risk and inoperable patients with severe aortic stenosis. However, despite current guideline recommendations, the use of transcatheter aortic valve replacement (TAVR) to treat severe aortic valve stenosis caused by degenerative leaflet thickening and calcification has not been widely adopted in low-risk patients. This reluctance among both cardiac surgeons and cardiologists could be due to concerns regarding clinical and subclinical valve thrombosis. Stent performance alongside increased aortic root and leaflet stresses in surgical bioprostheses has been correlated with complications such as thrombosis, migration and structural valve degeneration. Materials and Methods: Self-expandable catheter-based aortic valve replacement (Medtronic, Minneapolis, MN, USA), which was received by patients who developed transcatheter heart valve thrombosis, was investigated using high-resolution biomodelling from computed tomography scanning. Calcific blocks were extracted from a 250 CT multi-slice image for precise three-dimensional geometry image reconstruction of the root and leaflets. Results: Distortion of the stent was observed with incomplete cranial and caudal expansion of the device. The incomplete deployment of the stent was evident in the presence of uncrushed refractory bulky calcifications. This resulted in incomplete alignment of the device within the aortic root and potential dislodgment. Conclusion: A Finite Element Analysis (FEA) investigation can anticipate the presence of calcified refractory blocks, the deformation of the prosthetic stent and the development of paravalvular orifice, and it may prevent subclinical and clinical TAVR thrombosis. Here we clearly demonstrate that using exact geometry from high-resolution CT scans in association with FEA allows detection of persistent bulky calcifications that may contribute to thrombus formation after TAVR procedure.


2020 ◽  
Vol 41 (33) ◽  
pp. 3184-3197
Author(s):  
Arnold C T Ng ◽  
David R Holmes ◽  
Michael J Mack ◽  
Victoria Delgado ◽  
Raj Makkar ◽  
...  

Abstract Transcatheter aortic valve replacement (TAVR) has grown exponentially worldwide in the last decade. Due to the higher bleeding risks associated with oral anticoagulation and in patients undergoing TAVR, antiplatelet therapy is currently considered first-line antithrombotic treatment after TAVR. Recent studies suggest that some patients can develop subclinical transcatheter heart valve (THV) thrombosis after the procedure, whereby thrombus forms on the leaflets that can be a precursor to leaflet dysfunction. Compared with echocardiography, multidetector computed tomography is more sensitive at detecting THV thrombosis. Transcatheter heart valve thrombosis can occur while on dual antiplatelet therapy with aspirin and thienopyridine but significantly less with anticoagulation. This review summarizes the incidence and diagnostic criteria for THV thrombosis and discusses the pathophysiological mechanisms that may lead to thrombus formation, its natural history, potential clinical implications and treatment for these patients.


Author(s):  
Tamim M. Nazif ◽  
Thomas J. Cahill ◽  
David Daniels ◽  
James M. McCabe ◽  
Mark Reisman ◽  
...  

Background: Paravalvular regurgitation (PVR) after transcatheter aortic valve replacement is associated with adverse clinical outcomes. The SAPIEN 3 Ultra (Ultra) is a new generation balloon-expandable transcatheter heart valve with a modified external skirt that is designed to reduce PVR, but reports of clinical and echocardiographic outcomes are limited. The aim of this study was to compare short-term outcomes of patients undergoing transcatheter aortic valve replacement with the Ultra and the original SAPIEN 3 (S3) transcatheter heart valve in a large national registry. Methods: Data from The Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry was used to compare patients who underwent elective, transfemoral transcatheter aortic valve replacement with the Ultra or S3 transcatheter heart valve. Clinical and echocardiographic outcomes were analyzed in a propensity-matched cohort at discharge and 30 days. Results: Patients who underwent transcatheter aortic valve replacement with Ultra (N=1324) from January 2019 to February 2020 were propensity score–matched with patients treated with S3 (N=32 982) during the same period, resulting in 1324 matched pairs. There was no difference in the rate of device success between patients treated with Ultra and S3 (97.1% versus 98.0%, P =0.11). At hospital discharge, PVR was significantly reduced with Ultra compared with S3, with mild PVR in 9.0% versus 13.9% and moderate or greater PVR in 0.1% versus 0.4% (overall P <0.01). At 30 days, there were no differences between Ultra and S3 recipients in the rates of all-cause mortality or stroke (1.8% versus 2.8%, P =0.10), major vascular complications (1.1% versus 1.0%, P =0.84), or permanent pacemaker implantation (6.4% versus 6.2%, P =0.81). Conclusions: In this propensity-matched analysis from the Transcatheter Valve Therapy Registry, the Ultra transcatheter heart valve was associated with similar procedural and 30-day clinical outcomes, but reduced incidence of PVR, compared with S3. The clinical benefit of less PVR should be evaluated in longer-term studies.


2017 ◽  
Vol 2017 (2) ◽  
Author(s):  
Ambarish Gopal ◽  
Nathalia Ribeiro ◽  
John J Squiers ◽  
Elizabeth M Holper ◽  
Michael Black ◽  
...  

A major concern regarding transcatheter aortic valve replacement (TAVR) is leaflet thrombosis. Four-dimensional computed tomography (4D-CT) is the preferred imaging modality to evaluate patients with suspected valve thrombosis. To date, the abnormal findings visualized by 4D-CT suggestive of leaflet thrombosis have lacked pathologic confirmation from a surgically explanted valve in a surviving patient. Herein, we provide pathologic confirmation of thrombus formation following surgical explantation of a thrombosed TAVR prosthesis that was initially identified by 4D-CT. 


Sign in / Sign up

Export Citation Format

Share Document