High-throughput two-step LNA real time PCR assay for the quantitative detection and genotyping of HPV prognostic-risk groups

2009 ◽  
Vol 45 (4) ◽  
pp. 304-310 ◽  
Author(s):  
Elisa Leo ◽  
Simona Venturoli ◽  
Monica Cricca ◽  
Monica Musiani ◽  
Marialuisa Zerbini
2012 ◽  
Vol 95 (6) ◽  
pp. 1652-1655 ◽  
Author(s):  
Rakesh Kumar ◽  
K V Lalitha

Abstract A non-radio-labeled probe-based detection method was developed for rapid enumeration of Salmonella in seafood and water samples. A Salmonella-specific invA gene probe was developed using a digoxigenin-based non-radio labeling assay, which was evaluated with naturally contaminated seafood and water samples. The probe-based technique was further compared with the quantitative PCR assay. The method was specific for detection of different Salmonella serovars without any nonspecific hybridization with other Salmonella-related Enterobacteriaceae. The optimum labeling efficiency was determined for the labeled probe, and 10 pg/μL probe concentration was observed to be most efficient for detection of Salmonella colonies on nylon membrane. Quantification of Salmonella in naturally contaminated seafood and water samples (n = 21) was in the range 10–102 CFU/mL. The assay successfully quantified Salmonella in spiked seafood and water samples in the presence of background flora, and the entire assay was completed within 48 h. The probe-based assay was further evaluated with real-time PCR, and results showed that the assay was comparable to real-time PCR assay. Thus, this probe-based assay can be a rapid, useful, and alternative technique for quantitative detection of Salmonella in food, feed, and water samples.


1999 ◽  
Vol 37 (6) ◽  
pp. 1941-1947 ◽  
Author(s):  
Alexander J. Ryncarz ◽  
James Goddard ◽  
Anna Wald ◽  
Meei-Li Huang ◽  
Bernard Roizman ◽  
...  

We have developed a high-throughput, semiautomated, quantitative fluorescence-based PCR assay to detect and type herpes simplex virus (HSV) DNA in clinical samples. The detection assay, which uses primers to the type-common region of HSV glycoprotein B (gB), was linear from <10 to 108 copies of HSV DNA/20 μl of sample. Among duplicate samples in reproducibility runs, the assay showed less than 5% variability. We compared the fluorescence-based PCR assay with culture and gel-based liquid hybridization system with 335 genital tract specimens from HSV type 2 (HSV-2)-seropositive persons attending a research clinic and 380 consecutive cerebrospinal fluid (CSF) samples submitted to a diagnostic virology laboratory. Among the 162 culture-positive genital tract specimens, TaqMan PCR was positive for 157 (97%) specimens, whereas the quantitative-competitive PCR was positive for 144 (89%) specimens. Comparisons of the mean titer of HSV DNA detected by the two assays revealed that the mean titer detected by the gel-based system was slightly higher (median, 1 log). These differences in titers were in part related to the fivefold difference in the amount of HSV DNA used in the amplicon standards with the two assays. Among the 380 CSF samples, 42 were positive by both assays, 13 were positive only by the assay with the agarose gel, and 3 were positive only by the assay with the fluorescent probe. To define the subtype of HSV DNA detected in the screening assay, we also designed one set of primers which amplifies the gG regions of both types of HSV and probes which are specific to either HSV-1 (gG1) or HSV-2 (gG2). These probes were labeled with different fluorescent dyes (6-carboxyfluorescein for gG2 and 6-hexachlorofluorescein for gG1) to enable detection in a single PCR. In mixing experiments the probes discriminated the correct subtype in mixtures with up to a 7-log-higher concentration of the opposite subtype. The PCR typing results showed 100% concordance with the results obtained by assays with monoclonal antibodies against HSV-1 or HSV-2. Thus, while the real-time PCR is slightly less sensitive than the gel-based liquid hybridization system, the high throughput, the lack of contamination during processing, the better reproducibility, and the better ability to type the isolates rapidly make the real-time PCR a valuable tool for clinical investigation and diagnosis of HSV infection.


2007 ◽  
Vol 21 (5-6) ◽  
pp. 368-378 ◽  
Author(s):  
Anna Casabianca ◽  
Caterina Gori ◽  
Chiara Orlandi ◽  
Federica Forbici ◽  
Carlo Federico Perno ◽  
...  

2016 ◽  
Vol 12 (1) ◽  
Author(s):  
Gregorio Iraola ◽  
Ruben Pérez ◽  
Laura Betancor ◽  
Ana Marandino ◽  
Claudia Morsella ◽  
...  

2007 ◽  
Vol 41 (1) ◽  
pp. 118-126 ◽  
Author(s):  
Jonas Behets ◽  
Priscilla Declerck ◽  
Yasmine Delaedt ◽  
Lieve Verelst ◽  
Frans Ollevier

2005 ◽  
Vol 71 (4) ◽  
pp. 2190-2194 ◽  
Author(s):  
Morgan Guilbaud ◽  
Pierre de Coppet ◽  
Fabrice Bourion ◽  
Cinta Rachman ◽  
Hervé Prévost ◽  
...  

ABSTRACT A quantitative method based on a real-time PCR assay to enumerate Listeria monocytogenes in biofilms was developed. The specificity for L. monocytogenes of primers targeting the listeriolysin gene was demonstrated using a SYBR Green I real-time PCR assay. The number of L. monocytogenes detected growing in biofilms was 6 × 102 CFU/cm2.


Sign in / Sign up

Export Citation Format

Share Document