Comparative study of Vascularized Iliac Crest Graft vs Titanium Mesh Tray with Particulate Cancellous Bone and Marrow Method in Mandibular Reconstruction

2020 ◽  
Vol 78 (10) ◽  
pp. e94-e95
Author(s):  
K. Kawaguchi ◽  
T. Saito ◽  
M. Hasebe ◽  
Y. Hamada
2021 ◽  
Vol 11 ◽  
Author(s):  
Raúl Antúnez-Conde ◽  
José Ignacio Salmerón ◽  
Alberto Díez-Montiel ◽  
Marc Agea ◽  
Dafne Gascón ◽  
...  

IntroductionVertical discrepancy between the fibula flap and the native mandible results in difficult prosthetic rehabilitation. The aim of this study was to evaluate the outcomes of 3D reconstruction of the mandible in oncologic patients using three different techniques through virtual surgical planning (VSP), cutting guides, customized titanium mesh and plates with CAD/CAM technology, STL models and intraoperative dynamic navigation for implant placement. Material and methodsMaterial and MethodsThree different techniques for mandibular reconstruction and implant rehabilitation were performed in 14 oncologic patients. Five patients (36%) underwent VSP, cutting guides, STL models and a customized double-barrel titanium plate with a double-barrel flap and immediate implants. In six patients (43%), VSP, STL models and a custom-made titanium mesh (CAD/CAM) for 3D reconstruction with iliac crest graft over a fibula flap with deferred dental implants were performed. Three patients (21%) underwent VSP with cutting guides and customized titanium plates for mandibular reconstruction and implant rehabilitation using intraoperative dynamic navigation was accomplished. Vertical bone reconstruction, peri-implant bone resorption, implant success rate, effects of radiotherapy in vertical reconstruction, bone resorption and implant failure, mastication, aesthetic result and dysphagia were evaluated.ResultsSignificant differences in bone growth between the double-barrel technique and iliac crest graft with titanium mesh technique were found (p<0.002). Regarding bone resorption, there were no significant differences between the techniques (p=0.11). 60 implants were placed with an osseointegration rate of 91.49%. Five implants were lost during the osseointegration period (8%). Peri-implant bone resorption was measured with a mean of 1.27 mm. There was no significant difference between the vertical gain technique used and implant survival (p>0.385). Implant survival rates were higher in non-irradiated patients (p<0.017). All patients were rehabilitated with a fixed implant-supported prosthesis reporting a regular diet (80%), normal swallowing (85.7%) and excellent aesthetic results.ConclusionsMulti-stage implementation of VSP, STL models and cutting guides, CAD/CAM technology, customized plates and in-house dynamic implant navigation for mandibular defects increases bone-to-bone contact, resolves vertical discrepancy and improves operative efficiency with reduced complication rates and minimal bone resorption. It provides accurate reconstruction that optimizes implant placement, thereby improving facial symmetry, aesthetics and function.


2021 ◽  
Vol 10 (9) ◽  
pp. 1922
Author(s):  
Carlos Navarro Cuéllar ◽  
Manuel Tousidonis Rial ◽  
Raúl Antúnez-Conde ◽  
Santiago Ochandiano Caicoya ◽  
Ignacio Navarro Cuéllar ◽  
...  

Mandibular reconstruction with fibula flap shows a 3D discrepancy between the fibula and the remnant mandible. Eight patients underwent three-dimensional reconstruction of the fibula flap with iliac crest graft and dental implants through virtual surgical planning (VSP), stereolitographic models (STL) and CAD/CAM titanium mesh. Vertical ridge augmentation and horizontal dimensions of the fibula, peri-implant bone resorption of the iliac crest graft, implant success rate and functional and aesthetic results were evaluated. Vertical reconstruction ranged from 13.4 mm to 10.1 mm, with an average of 12.22 mm. Iliac crest graft and titanium mesh were able to preserve the width of the fibula, which ranged from 8.9 mm to 11.7 mm, with an average of 10.1 mm. A total of 38 implants were placed in the new mandible, with an average of 4.75 ± 0.4 implants per patient and an osseointegration success rate of 94.7%. Two implants were lost during the osseointegration period (5.3%). Bone resorption was measured as peri-implant bone resorption at the mesial and distal level of each implant, with a variation between 0.5 mm and 2.4 mm, and with a mean of 1.43 mm. All patients were rehabilitated with a fixed implant prosthesis with good aesthetic and functional results.


Author(s):  
Shigeo Ishikawa ◽  
Kazyuki Yusa ◽  
Kaoru Edamatsu ◽  
Shohei Ueda ◽  
Ayako Sugano ◽  
...  

A particulate cancellous bone and marrow (PCBM) graft combined with titanium (Ti-) mesh tray has become one of the most popular mandibular reconstruction methods. The technique has been applied to the mandibular discontinuity defects after segmental mandibulectomy. To the best of our knowledge, there are no reports on using the technique after hemimandibulectomy, during which a wide mandibular resection, including the condyle, is performed. Here we report firstly a case of mandibular reconstruction after hemimandibulectomy, using a plate and soft-tissue free flap, followed by a Ti-mesh and PCBM harvested from the bilateral posterior ilia, which was successful. This case report first revealed how bone resorption occurred clinically in mandibular reconstruction using PCBM and Ti-mesh tray after hemimandibulectomy. We also revealed the high predictability of the mandibular reconstruction using PCBM and Ti-mesh tray after hemimandibulectomy. Our report also provides a guiding principle to overcome the limitation of mandibular reconstruction using PCBM and Ti-mesh tray after hemimandibulectomy. However, our manuscript has limited evidence being a case report.


2012 ◽  
Vol 2 (2) ◽  
pp. 90-96 ◽  
Author(s):  
Amiya Agrawal ◽  
Divya Mehrotra ◽  
Shadab Mohammad ◽  
R.K. Singh ◽  
Santhosh Kumar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document