Energy, exergy, and eco-environment modeling of proton exchange membrane electrolyzer coupled with power cycles: Application in natural gas pressure reduction stations

2021 ◽  
Vol 512 ◽  
pp. 230490
Author(s):  
Amir Ebrahimi-Moghadam ◽  
Mahmood Farzaneh-Gord
Energy ◽  
2020 ◽  
pp. 119362
Author(s):  
Seok-Ho Seo ◽  
Si-Doek Oh ◽  
Jinwon Park ◽  
Hwanyeong Oh ◽  
Yoon-Young Choi ◽  
...  

2005 ◽  
Vol 2 (4) ◽  
pp. 263-267 ◽  
Author(s):  
Darrell D. Massie ◽  
Daisie D. Boettner ◽  
Cheryl A. Massie

As part of a one-year Department of Defense demonstration project, proton exchange membrane fuel cell systems have been installed at three residences to provide electrical power and waste heat for domestic hot water and space heating. The 5kW capacity fuel cells operate on reformed natural gas. These systems operate at preset levels providing power to the residence and to the utility grid. During grid outages, the residential power source is disconnected from the grid and the fuel cell system operates in standby mode to provide power to critical loads in the residence. This paper describes lessons learned from installation and operation of these fuel cell systems in existing residences. Issues associated with installation of a fuel cell system for combined heat and power focus primarily on fuel cell siting, plumbing external to the fuel cell unit required to support heat recovery, and line connections between the fuel cell unit and the home interior for natural gas, water, electricity, and communications. Operational considerations of the fuel cell system are linked to heat recovery system design and conditions required for adequate flow of natural gas, air, water, and system communications. Based on actual experience with these systems in a residential setting, proper system design, component installation, and sustainment of required flows are essential for the fuel cell system to provide reliable power and waste heat.


Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4792 ◽  
Author(s):  
Burin Yodwong ◽  
Damien Guilbert ◽  
Matheepot Phattanasak ◽  
Wattana Kaewmanee ◽  
Melika Hinaje ◽  
...  

In electrolyzers, Faraday’s efficiency is a relevant parameter to assess the amount of hydrogen generated according to the input energy and energy efficiency. Faraday’s efficiency expresses the faradaic losses due to the gas crossover current. The thickness of the membrane and operating conditions (i.e., temperature, gas pressure) may affect the Faraday’s efficiency. The developed models in the literature are mainly focused on alkaline electrolyzers and based on the current and temperature change. However, the modeling of the effect of gas pressure on Faraday’s efficiency remains a major concern. In proton exchange membrane (PEM) electrolyzers, the thickness of the used membranes is very thin, enabling decreasing ohmic losses and the membrane to operate at high pressure because of its high mechanical resistance. Nowadays, high-pressure hydrogen production is mandatory to make its storage easier and to avoid the use of an external compressor. However, when increasing the hydrogen pressure, the hydrogen crossover currents rise, particularly at low current densities. Therefore, faradaic losses due to the hydrogen crossover increase. In this article, experiments are performed on a commercial PEM electrolyzer to investigate Faraday’s efficiency based on the current and hydrogen pressure change. The obtained results have allowed modeling the effects of Faraday’s efficiency by a simple empirical model valid for the studied PEM electrolyzer stack. The comparison between the experiments and the model shows very good accuracy in replicating Faraday’s efficiency.


2010 ◽  
Vol 18 (6) ◽  
pp. 988-994 ◽  
Author(s):  
Cheng BAO ◽  
Qingquan SU ◽  
Wanliang MI ◽  
Zhiyuan LI ◽  
Quan BI ◽  
...  

Author(s):  
Daisie D. Boettner ◽  
Cheryl A. Massie ◽  
Darrell D. Massie

As part of a one-year Department of Defense demonstration project, proton exchange membrane fuel cell systems have been installed at three residences to provide electrical power and waste heat for domestic hot water and space heating. The 5 kW-capacity fuel cells operate on reformed natural gas. These systems operate at preset levels providing power to the residence and to the utility grid. During grid outages, the residential power source is disconnected from the grid and the fuel cell system operates in standby mode to provide power to critical loads in the residence. This paper describes lessons learned from installation and operation of these fuel cell systems in existing residences. Issues associated with installation of a fuel cell system for combined heat and power focus primarily on fuel cell siting, plumbing external to the fuel cell unit required to support heat recovery, and line connections between the fuel cell unit and the home interior for natural gas, water, electricity, and communications. Operational considerations of the fuel cell system are linked to heat recovery system design and conditions required for adequate flow of natural gas, air, water, and system communications. Based on actual experience with these systems in a residential setting, proper system design, component installation, and sustainment of required flows are essential for the fuel cell system to provide reliable power and waste heat.


Sign in / Sign up

Export Citation Format

Share Document