scholarly journals Comparing the Costs and Outcomes of a Twin Interlocking Derotation and Compression Screw Cephalomedullary Nail (2-Screw Nail)* with a Single Screw Cephalomedullary Nail (Single-Screw Nail) in Patients with Intertrochanteric HIP Fractures

2018 ◽  
Vol 21 ◽  
pp. S171
Author(s):  
L Nherera ◽  
P Trueman ◽  
A Horner
2020 ◽  
Author(s):  
Shou-Chao Du ◽  
Xiu-Hui Wang ◽  
Shi-Min Chang

Abstract Background: InterTan is a specific type of cephalomedullary nail with a twin interlocking de-rotation and compression screw, which has inherent ability of anti-rotation. Whether to tighten or not to tighten the preloaded setscrew in InterTan nail is controversial in clinical practice.Methods: We retrospectively collected four nonunion cases of unstable pertrochanteric femur fractures (AO/OTA-31A2), all were treated with InterTan nail and the preloaded setscrew was tightened in order to prevent further sliding and femoral neck shortening. Results: After 6 months to 2 years follow-up, the fractures showed nonunion in radiography and the patients complained slight to middle degrees of pain, and had to use walking stick assistant in activities of daily life. Tightening the pre-loaded setscrew to prevent postoperative secondary sliding as static constructs might keep the femoral neck length, but lose the opportunity of telescoping for fracture impaction, and take the risk of healing complications, such as fracture nonunion, femoral head cutout or nail breakage.Conclusions: As the harm outweighs benefit, we advocate the preloaded setscrew in InterTan nail should not be tightened in pertrochanteric hip fractures (AO/OTA-31A1 and A2).


2021 ◽  
Vol 12 ◽  
pp. 215145932199064
Author(s):  
Shou-Chao Du ◽  
Xiu-Hui Wang ◽  
Shi-Min Chang

Background: InterTAN is a specific type of cephalomedullary nail with a twin interlocking de-rotation and compression screw, which has inherent ability of anti-rotation. Whether to tighten or not to tighten the preloaded setscrew to allow or not allow secondary sliding in InterTan nail is controversial in clinical practice. Methods: We retrospectively collected 4 nonunion cases of unstable pertrochanteric femur fractures (AO/OTA-31A2), all were treated with InterTan nail and the preloaded setscrew was tightened in order to prevent further secondary sliding and femoral neck shortening. Results: After 6 months to 2 years follow-up, the fractures showed nonunion in radiography and the patients complained slight to middle degrees of pain, and had to use walking stick assistant in activities of daily life. Tightening the pre-loaded setscrew to prevent postoperative secondary sliding as static constructs might keep the femoral neck length, but lose the opportunity of telescoping for fracture impaction, and take the risk of healing complications, such as fracture nonunion, femoral head cutout or nail breakage. Conclusions: As the harm outweighs benefit, we advocate the preloaded setscrew in InterTan nail should not be tightened in standard-obliquity pertrochanteric hip fractures (AO/OTA-31A1 and A2).


Hand ◽  
2021 ◽  
pp. 155894472097411
Author(s):  
Luke T. Nicholson ◽  
Kristen M. Sochol ◽  
Ali Azad ◽  
Ram Kiran Alluri ◽  
J. Ryan Hill ◽  
...  

Background: Management of scaphoid nonunions with bone loss varies substantially. Commonly, internal fixation consists of a single headless compression screw. Recently, some authors have reported on the theoretical benefits of dual-screw fixation. We hypothesized that using 2 headless compression screws would impart improved stiffness over a single-screw construct. Methods: Using a cadaveric model, we compared biomechanical characteristics of a single tapered 3.5- to 3.6-mm headless compression screw with 2 tapered 2.5- to 2.8-mm headless compression screws in a scaphoid waist nonunion model. The primary outcome measurement was construct stiffness. Secondary outcome measurements included load at 1 and 2 mm of displacement, load to failure for each specimen, and qualitative assessment of mode of failure. Results: Stiffness during load to failure was not significantly different between single- and double-screw configurations ( P = .8). Load to failure demonstrated no statistically significant difference between single- and double-screw configurations. Using a qualitative assessment, the double-screw construct maintained rotational stability more than the single-screw construct ( P = .029). Conclusions: Single- and double-screw fixation constructs in a cadaveric scaphoid nonunion model demonstrate similar construct stiffness, load to failure, and load to 1- and 2-mm displacement. Modes of failure may differ between constructs and represent an area for further study. The theoretical benefit of dual-screw fixation should be weighed against the morphologic limitations to placing 2 screws in a scaphoid nonunion.


Author(s):  
Nishant Kumar ◽  
Dhruv Sharma ◽  
Kuljit Kumar

<p class="abstract"><strong>Background:</strong> <span lang="EN-IN">Hip fractures are recognized to be a major public health problem. Key determinants of hip fractures include age, osteoporosis, and falls. In these determinants socioeconomic status, have not been well explored. Under eccentric loading, high bending loads occur, leading to failure of the osteosynthetis anchorage at the center of the femoral head.The introduction of the reconstruction nail has broadened the indications for the intramedullary fixation of difficult femoral fractures. The operative technique is however complicated. Some technical difficulties encountered during its use are presented together with guidance to allow these problems to be avoided.</span></p><p class="abstract"><strong>Methods:</strong> <span lang="EN-IN">This Study had included 47 cases which were operated by single surgeon and use of different implant (cephalomedullary nail) was randomized irrespective of fracture types and pattern. This study was done over a period of 12 months (October 2013 to October 2014) with 1 month, 3 months, 6 months, 12 months follow up. At every visit patient were assessed as per Oxford hip score. Type of implant used was<strong> </strong>PFNA<strong>,</strong> Intertan<strong>, </strong>Sirus Nail</span>.<strong></strong></p><p class="abstract"><strong>Results:</strong> <span lang="EN-IN">The mean age of the patients was 65.68 (±13.55) years. Severe pain was observed among majority of the patients at one month (70.2%) which became mild (40.4%) and moderate (34%) at 3 months. Very mild pain was found in 36.2% patients at 6 months and in 61.7% at 12 months. The limping was all the time among all the patients at one month. However, the limping was found often in 46.8% at 3 months and sometimes in 57.4% at 6 months and 53.2% at 12 months. The hip score was found to be severe among all the patients at one month. However, moderate to severe hip was in 46.8% patients at 3 months, mild to moderate was in 57.4% at 6 months and satisfactory joint function was in 68.1% at 12 months. The comparison of Hip score according to long or short nail at one 3, 6 and 12 months showed no difference. </span></p><p class="abstract"><strong>Conclusions:</strong> <span lang="EN-IN">Cephalomedullary nails with adequate technique so that the lag screws by purchase in the centre-centre or posterior-inferior quadrant combines the benefit of sliding hip screw as well as intramedullary implants. So we recommend the use of cephalomedullary nails in proximal femur fractures especially the unstable fractures.</span></p>


1985 ◽  
Vol &NA; (201) ◽  
pp. 123???129
Author(s):  
NEIL J. COBELLI ◽  
ARTHUR H. SADLER