scholarly journals A meta-analysis of integrated compression screw compared to single screw nails using a single lag screw or single helical blade screw for intertrochanteric hip fractures

2018 ◽  
Vol 3 (4) ◽  
Author(s):  
Nherera LM ◽  
Trueman P ◽  
Horner A ◽  
Johnstone AJ ◽  
Watson JT
Hand ◽  
2021 ◽  
pp. 155894472097411
Author(s):  
Luke T. Nicholson ◽  
Kristen M. Sochol ◽  
Ali Azad ◽  
Ram Kiran Alluri ◽  
J. Ryan Hill ◽  
...  

Background: Management of scaphoid nonunions with bone loss varies substantially. Commonly, internal fixation consists of a single headless compression screw. Recently, some authors have reported on the theoretical benefits of dual-screw fixation. We hypothesized that using 2 headless compression screws would impart improved stiffness over a single-screw construct. Methods: Using a cadaveric model, we compared biomechanical characteristics of a single tapered 3.5- to 3.6-mm headless compression screw with 2 tapered 2.5- to 2.8-mm headless compression screws in a scaphoid waist nonunion model. The primary outcome measurement was construct stiffness. Secondary outcome measurements included load at 1 and 2 mm of displacement, load to failure for each specimen, and qualitative assessment of mode of failure. Results: Stiffness during load to failure was not significantly different between single- and double-screw configurations ( P = .8). Load to failure demonstrated no statistically significant difference between single- and double-screw configurations. Using a qualitative assessment, the double-screw construct maintained rotational stability more than the single-screw construct ( P = .029). Conclusions: Single- and double-screw fixation constructs in a cadaveric scaphoid nonunion model demonstrate similar construct stiffness, load to failure, and load to 1- and 2-mm displacement. Modes of failure may differ between constructs and represent an area for further study. The theoretical benefit of dual-screw fixation should be weighed against the morphologic limitations to placing 2 screws in a scaphoid nonunion.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Firas J. Raheman ◽  
Djamila M. Rojoa ◽  
Jvalant Nayan Parekh ◽  
Reshid Berber ◽  
Robert Ashford

AbstractIncidence of hip fractures has remained unchanged during the pandemic with overlapping vulnerabilities observed in patients with hip fractures and those infected with COVID-19. We aimed to investigate the independent impact of COVID-19 infection on the mortality of these patients. Healthcare databases were systematically searched over 2-weeks from 1st–14th November 2020 to identify eligible studies assessing the impact of COVID-19 on hip fracture patients. Meta-analysis of proportion was performed to obtain pooled values of prevalence, incidence and case fatality rate of hip fracture patients with COVID-19 infection. 30-day mortality, excess mortality and all-cause mortality were analysed using a mixed-effects model. 22 studies reporting 4015 patients were identified out of which 2651 (66%) were assessed during the pandemic. An excess mortality of 10% was seen for hip fractures treated during the pandemic (OR 2.00, p = 0.007), in comparison to the pre-pandemic controls (5%). Estimated mortality of COVID-19 positive hip fracture patients was four-fold (RR 4.59, p < 0.0001) and 30-day mortality was 38.0% (HR 4.73, p < 0.0001). The case fatality rate for COVID-19 positive patients was 34.74%. Between-study heterogeneity for the pooled analysis was minimal (I2 = 0.00) whereas, random effects metaregression identified subgroup heterogeneity for male gender (p < 0.001), diabetes (p = 0.002), dementia (p = 0.001) and extracapsular fractures (p = 0.01) increased risk of mortality in COVID-19 positive patients.


2021 ◽  
pp. 112070002098506
Author(s):  
James R Onggo ◽  
Mithun Nambiar ◽  
Jason D Onggo ◽  
Anuruban Ambikaipalan ◽  
Parminder J Singh ◽  
...  

Background/Aim: This study aims to determine the safety and efficacy of integrated dual lag screw (IDL) cephalomedullary nails (CMN) when compared with single lag screw (SL) constructs, in the internal fixation of intertrochanteric femoral fractures. Methods: The Smith & Nephew InterTan IDL was compared with SL CMN group consisting of the Stryker Gamma-3 (G3) and Synthes Proximal Femoral Nail Antirotation (PFNA) CMN. A multi-database search was performed according to PRISMA guidelines. Data from studies assessing the clinical and radiological outcomes, complications and perioperative parameters of InterTan versus G3 or PFNA CMN in patients with intertrochanteric femoral fractures were extracted and analysed. Results: 15 studies were included in this meta-analysis, consisting of 2643 patients. InterTan was associated with lower complication rates in terms of all-cause revisions (OR 0.34; 95% CI, 0.22–0.51; p < 0.001), cut-outs (OR 0.30; 95% CI, 0.17–0.51; p < 0.001), medial or lateral screw migration (OR 0.19; 95% CI, 0.06–0.65; p = 0.008) as well as persistent hip and thigh pain (OR 0.65; 95% CI, 0.47–0.90; p = 0.008). In terms of perioperative parameters, InterTan is associated with longer operative times (MD 5.57 minutes; 95% CI, 0.37–10.78 minutes, p = 0.04) and fluoroscopy times (MD 38.89 seconds, 95% CI, 15.88–61.91 seconds; p < 0.001). There was no statistically significant difference in terms of clinical Harris Hip Score and radiological outcomes, non-union, haematoma, femoral fractures, varus collapse, length of stay and mean intraoperative blood loss between the 2 groups. Conclusions: Integrated dual lag screw cephalomedullary nails are associated with fewer revisions and complications. However, there is insufficient data to suggest that either nail construct is associated with better functional outcomes.


2021 ◽  
Vol 50 ◽  
pp. 654-660
Author(s):  
Jeetinder K. Makkar ◽  
Narinder P. Singh ◽  
Nidhi Bhatia ◽  
Tanvir Samra ◽  
Preet Mohinder Singh

Sign in / Sign up

Export Citation Format

Share Document