Experimental analysis of shell and tube heat exchanger using flower baffle plate configuration

2020 ◽  
Vol 21 ◽  
pp. 419-424
Author(s):  
J. Mahendran
Author(s):  
Songchai Pankaew ◽  
Samerkhwan Tantikul ◽  
Thanasit Wongsiriamnuay ◽  
Tipapon Khamdaeng ◽  
Nakorn Tippayawong ◽  
...  

Author(s):  
Gayatri Kuchi ◽  
Valery Ponyavin ◽  
Yitung Chen ◽  
Steven Sherman ◽  
Anthony E. Hechanova

Numerical simulations of a high temperature shell and tube heat exchanger and chemical decomposer (thereafter — heat exchanger) with straight tube configuration have been performed using Fluent 6.2.16 code to examine flow distribution on the tube side. The heat exchanger can be a part of sulfur iodine thermochemical water splitting cycle which is one of the most studied cycles for hydrogen production. Uniformity of the flow distribution in the heat exchanger is very critical because the flow maldistribution among the tube or shell sides can result in decreasing of chemical decomposition and increasing of pumping power. In the current study the flow rate uniformity in the heat exchanger tubes has been investigated. Simulations of the straight tube configuration, tube configuration with baffle plate arrangement and with pebble bed region inside the tubes were performed to examine flow distribution on the tube side. It was found the flow maldistribution along the tube direction is very serious with the simple tube configuration. An improvement of the header configuration has been done by introducing a baffle plate in to the header section. With the introduction of the baffle plate, there was a noticeable decrease in the flow maldistribution in the tubes. Uniformity of flow was also investigated with catalytic bed inside the tubes. A significant decrease in flow maldistribution was observed with this arrangement. But if the catalytic bed zone is created on the shell side, then the improved header configuration with a baffle plate is best suitable to avoid flow maldistribution.


Author(s):  
Leonardo Cavalheiro Martinez ◽  
Leonardo Cavalheiro Martinez ◽  
Viviana Mariani ◽  
Marcos Batistella Lopes

2020 ◽  
Vol 0 (0) ◽  
Author(s):  
Swanand Gaikwad ◽  
Ashish Parmar

AbstractHeat exchangers possess a significant role in energy transmission and energy generation in most industries. In this work, a three-dimensional simulation has been carried out of a shell and tube heat exchanger (STHX) consisting of segmental baffles. The investigation involves using the commercial code of ANSYS CFX, which incorporates the modeling, meshing, and usage of the Finite Element Method to yield numerical results. Much work is available in the literature regarding the effect of baffle cut and baffle spacing as two different entities, but some uncertainty pertains when we discuss the combination of these two parameters. This study aims to find an appropriate mix of baffle cut and baffle spacing for the efficient functioning of a shell and tube heat exchanger. Two parameters are tested: the baffle cuts at 30, 35, 40% of the shell-inside diameter, and the baffle spacing’s to fit 6,8,10 baffles within the heat exchanger. The numerical results showed the role of the studied parameters on the shell side heat transfer coefficient and the pressure drop in the shell and tube heat exchanger. The investigation shows an increase in the shell side heat transfer coefficient of 13.13% when going from 6 to 8 baffle configuration and a 23.10% acclivity for the change of six baffles to 10, for a specific baffle cut. Evidence also shows a rise in the pressure drop with an increase in the baffle spacing from the ranges of 44–46.79%, which can be controlled by managing the baffle cut provided.


Sign in / Sign up

Export Citation Format

Share Document