Effect of external strengthening on the flexural capacity of cold-formed steel beams

Author(s):  
M. Anbarasu ◽  
A.R. Dar ◽  
Amer I. Rather ◽  
M. Adil Dar
2014 ◽  
Vol 74 ◽  
pp. 104-117 ◽  
Author(s):  
Luís Laím ◽  
João Paulo C. Rodrigues ◽  
Luis Simões da Silva

2021 ◽  
Vol 164 ◽  
pp. 107831
Author(s):  
Mahmoud Hosseinpour ◽  
Mehran Zeynalian ◽  
Abdoreza Ataei ◽  
Maryam Daei

2017 ◽  
Vol 79 (5) ◽  
Author(s):  
Nahushananda Chakravarthy ◽  
Sivakumar Naganathan ◽  
Jonathan Tan Hsien Aun ◽  
Sreedhar Kalavagunta ◽  
Kamal Nasharuddin Mustapha ◽  
...  

Cold formed steel differ from hot rolled steel by its lesser thickness and weight. The cold formed steel applicable in roof purlin, pipe racks and wall panels etc. Due its lesser wall thickness the cold formed steel member subjected to buckling. The enhancement of load carrying capacity of the cold formed steel member can be achieved by external strengthening of CFRP. In this study cold formed channel members connected back to back to form I shaped cross section using screws. These built up beam members were 300mm, 400mm and 500mm in length with 100mm screw spacing and edge distance of 50mm were chosen for testing. CFRP fabric cut according to length, width of built up beams and wrapped outer surface of beam using epoxy resin. Experiments were carried out in two sets firstly plain built up beams and secondly CFRP wrapped beams. The test results shows that increased load carrying capacity and reduction in deflection due to CFRP strengthening. Experimental results were compared with AISI standards which are in good agreement. Experimental results shows that CFRP strengthening is economic and reliable.


2016 ◽  
Vol 12 (3) ◽  
Author(s):  
Uiatan Aguiar Nogueira ◽  
Matilde Batista Melo ◽  
Daniel De Lima Araujo

RESUMO: A Análise de elementos estruturais, realizadas durante as etapas de projeto de uma estrutura, é parte fundamental para garantia de bom desempenho e estabilidade do sistema estrutural. Na execução de algumas estruturas, como as coberturas em edificações, é usual o emprego de perfis leves de aço formados a frio devido ao seu baixo peso. Esta pesquisa tem por objetivo avaliar a eficiência estrutural desses perfis quando comparados, por exemplo, aos perfis soldados compactos. Para tanto, foram realizados ensaios de flexão em quatro vigas biapoiadas submetidas a duas forças concentradas, de forma a se obter flexão pura no meio do vão das vigas. Estas foram instrumentadas para a determinação da sua rigidez e da sua resistência à flexão. A principal contribuição deste trabalho é demonstrar a eficiência estrutural de perfis formados a frio em seção caixa submetidos à flexão em comparação com perfis de seção tipo “H” soldados. ABSTRACT: The analysis of structural elements, in a structure’s design, is an essential step to ensure good performance and stability of the structural system. In any types of structures, such as roofing in buildings, it’s usual using cold-formed steel beams due to their small weight. This research seeks to evaluate the structural efficiency of cold-formed steel beams when compared, for example, to compact welded steel beams. Thus, bending tests were performed in four simply supported beams submitted to two concentrated loads, in order to obtain pure flexure at the mid-span of the beams. These beams were instrumented for the determination of their rigidity and bending strength. The results showed that the cold-formed steel beam, box-shaped, presented structural efficiency similar to the welded steel beam “H” shaped.


2016 ◽  
Vol 104 ◽  
pp. 54-61 ◽  
Author(s):  
Bin Wang ◽  
Guillaume L. Bosco ◽  
Benoit P. Gilbert ◽  
Hong Guan ◽  
Lip H. Teh

2016 ◽  
Vol 121 ◽  
pp. 216-228 ◽  
Author(s):  
Mohammed H. Serror ◽  
Emad M. Hassan ◽  
Sherif A. Mourad

2018 ◽  
Vol 1146 ◽  
pp. 142-151
Author(s):  
Viorel Ungureanu ◽  
Ioan Both ◽  
Mircea Burca ◽  
Ştefan Benzar ◽  
Thai Hoang Nguyen ◽  
...  

Within the WELLFORMED research project, ongoing at the CEMSIG Research Center of the Politehnica University of Timisoara, a new technological solution was proposed for built-up beams made of corrugated steel sheets for the web and thin-walled cold-formed steel profiles for the flanges, connected by spot welding. The research project integrates an extensive experimental program on such beams, using full scale specimens, to demonstrate the feasibility of the proposed solutions and to assess their performance, followed by numerical simulations to characterize and optimize the connecting details. The present paper presents the results of a large experimental program, on small specimens subjected to shear, consisting of two or three layers of steel sheet connected by spot welding.


Sign in / Sign up

Export Citation Format

Share Document