Surface Roughness Optimization During Machining Of Niti Shape Memory Alloy By EDM Through Taguchi’s Technique

2020 ◽  
Vol 29 ◽  
pp. 343-347 ◽  
Author(s):  
Anshul Gangele ◽  
Ajay Mishra
2021 ◽  
Vol 22 (2) ◽  
pp. 507
Author(s):  
Mateusz Dulski ◽  
Robert Gawecki ◽  
Sławomir Sułowicz ◽  
Michal Cichomski ◽  
Alicja Kazek-Kęsik ◽  
...  

Recent years have seen the dynamic development of methods for functionalizing the surface of implants using biomaterials that can mimic the physical and mechanical nature of native tissue, prevent the formation of bacterial biofilm, promote osteoconduction, and have the ability to sustain cell proliferation. One of the concepts for achieving this goal, which is presented in this work, is to functionalize the surface of NiTi shape memory alloy by an atypical glass-like nanocomposite that consists of SiO2-TiO2 with silver nanoparticles. However, determining the potential medical uses of bio(nano)coating prepared in this way requires an analysis of its surface roughness, tribology, or wettability, especially in the context of the commonly used reference coat-forming hydroxyapatite (HAp). According to our results, the surface roughness ranged between (112 ± 3) nm (Ag-SiO2)—(141 ± 5) nm (HAp), the water contact angle was in the range (74.8 ± 1.6)° (Ag-SiO2)—(70.6 ± 1.2)° (HAp), while the surface free energy was in the range of 45.4 mJ/m2 (Ag-SiO2)—46.8 mJ/m2 (HAp). The adhesive force and friction coefficient were determined to be 1.04 (Ag-SiO2)—1.14 (HAp) and 0.247 ± 0.012 (Ag-SiO2) and 0.397 ± 0.034 (HAp), respectively. The chemical data showed that the release of the metal, mainly Ni from the covered NiTi substrate or Ag from Ag-SiO2 coating had a negligible effect. It was revealed that the NiTi alloy that was coated with Ag-SiO2 did not favor the formation of E. coli or S. aureus biofilm compared to the HAp-coated alloy. Moreover, both approaches to surface functionalization indicated good viability of the normal human dermal fibroblast and osteoblast cells and confirmed the high osteoconductive features of the biomaterial. The similarities of both types of coat-forming materials indicate an excellent potential of the silver-silica composite as a new material for the functionalization of the surface of a biomaterial and the development of a new type of functionalized implants.


Coatings ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1259
Author(s):  
Emre Altas ◽  
Hasan Gokkaya ◽  
Meltem Altin Karatas ◽  
Dervis Ozkan

The aim of this study was to optimize machining parameters to obtain the smallest average surface roughness (Ra) and flank wear (Vb) values as a result of the surface milling of a nickel-titanium (NiTi) shape memory alloy (SMA) with uncoated cutting tools with different nose radius (rε) under dry cutting conditions. Tungsten carbide cutting tools with different rε (0.4 mm and 0.8 mm) were used in milling operations. The milling process was performed as lateral/surface cutting at three different cutting speeds (Vc) (20, 35 and 50 m/min), feed rates (fz) (0.03, 0.07 and 0.14 mm/tooth) and a constant axial cutting depth (0.7 mm). The effects of machining parameters in milling experiments were investigated based on the Taguchi L18 (21 × 32) orthogonal sequence, and the data obtained were analyzed using the Minitab 17 software. To determine the effects of processing parameters on Ra and Vb, analysis of variance (ANOVA) was used. The analysis results reveal that the dominant factor affecting the Ra is the cutting tool rε, while the main factor affecting Vb is the fz. Since the predicted values and measured values are very close to each other, it can be said that optimization is correct according to the validation test results.


2017 ◽  
Vol 700 ◽  
pp. 132-139 ◽  
Author(s):  
Chuanliang Shen ◽  
Zhipeng Wu ◽  
Zhenhai Gao ◽  
Xiaoyu Ma ◽  
Shengtong Qiu ◽  
...  

Sign in / Sign up

Export Citation Format