The effect of hydrogen sulfide, carbon monoxide and water on the performance of a PDMS membrane in carbon dioxide/nitrogen separation

2010 ◽  
Vol 350 (1-2) ◽  
pp. 189-199 ◽  
Author(s):  
Colin A. Scholes ◽  
Geoff W. Stevens ◽  
Sandra E. Kentish
1997 ◽  
Vol 62 (4) ◽  
pp. 609-619 ◽  
Author(s):  
Vlastimil Kubáň

Ammonia (up to 0.3 vol.%) can be determined (RSDs < 2%) after separation from a process gas stream containing (vol.%): carbon dioxide (0.3-20), hydrogen sulfide (< 0.4), hydrogen cyanide (< 1.5 . 10-4), sulfur dioxide (1), carbon monoxide (< 3) in 50-90 vol.% nitrogen and hydrocarbons. The ammonia content in sample is determined through changes in the conductivity of an acceptor stream (3 mM boric acid) caused by absorption of the analyte passed through a Nafion capillary membrane.


2013 ◽  
Vol 5 (1) ◽  
pp. 63-70
Author(s):  
Aidil Zamri

Biogas is a gas fermentation of organic materials which contain most of the gas methane, carbon dioxide, few of carbon monoxide, hydrogen, hydrogen sulfide, nitrogen and ammonia. One of technological development of biogas production is anaerobic reactor. The processing of biogas technology is influenced by several factors, such as temperature and humidity. In this study, temperature is adjusted using a spiral system and biogas reactor which submerged into the water. The temperature of water can be controlled. In another case there is reactor without temperature setting as a comparison. The observation shows that the reactor in the water produces most biogas, reactor spiral in second place and reactor without heating in the last one.


1976 ◽  
Vol 59 (6) ◽  
pp. 1404-1408
Author(s):  
Wilson L Brannon ◽  
Walter R Benson ◽  
George Schwartzman

Abstract The feasibility of examining medicinal gases for trace impurities, using an infrared spectrophotometer in conjunction with a 10 m gas cell, was investigated. Many of the impurities for which the USP includes limits were detected and measured at concentrations at or below those permitted by the USP; these include sulfur dioxide, carbon dioxide, carbon monoxide, and water. However, others (hydrogen sulfide, nitric oxide, and nitrogen dioxide) were not detected at these levels by this technique. Methane was found at low levels in some samples.


1962 ◽  
Vol 2 (03) ◽  
pp. 197-202
Author(s):  
Robert B. Grieves ◽  
George Thodos

Abstract A method has been developed for predicting the critical temperatures and critical pressures of binary mixtures of carbon dioxide, hydrogen sulfide, nitrogen, hydrogen, carbon monoxide and oxygen with the normal paraffin hydrocarbons. For carbon-dioxide and hydrogen-sulfide systems, relations are presented that take into account the peculiar behavior of mixtures with closely boiling components, such as carbon dioxide-ethane and hydrogen sulfide-propane mixtures which exhibit minimum critical temperature points. For hydrogen, nitrogen and carbon-monoxide systems, the extreme critical behavior caused by wide differences in pure component properties is established. In addition, those fixed gas-paraffin systems which resemble paraffin-paraffin systems are also accounted for. For a mixture of known composition, the pure component critical temperatures, critical pressures and normal boiling points are all that are required to determine its critical point. Graphical relations are presented relating Tc and Pc of the mixture to the pure component properties. From the treatment of 12 carbon-dioxide and hydrogen-sulfide systems reported in the literature (74 mixtures), the expected error for the critical temperature is approximately 1.5 per cent, and for the critical pressure, approximately 2 per cent. From the treatment of six hydrogen, nitrogen and carbon-monoxide systems reported in the literature (30 mixtures), the expected error for both the critical temperature and critical pressure is approximately 2.5 per cent. The relationships, which have been developed with only normal paraffins as the hydrocarbon components, may be extended to those isoparaffins and olefins which fall within the allowable volatility ranges. Introduction Many of the fixed gases - carbon dioxide, hydrogen sulfide, nitrogen, hydrogen, carbon monoxide and oxygen - occur in natural mixtures with hydrocarbons. Carbon dioxide and hydrogen sulfide are frequent components of the fluids produced from underground petroleum reservoirs. Nitrogen, carbon dioxide and hydrogen sulfide are present in varying quantities in most natural gases and gas-condensate well effluents. Hydrogen mixtures are of considerable interest in many phases of refining processes of petroleum. The determination of the critical temperatures and critical pressures of such mixtures is of value in vapor-liquid equilibrium studies, for the prediction of the characteristics of underground reservoirs, and for reduced-state correlations of PVT, transport and thermodynamic properties. The accurate estimation of the critical point for binary mixtures is an important initial step toward a complete analysis for the establishment of the critical temperatures and pressures of multicomponent mixtures. Methods for predicting the critical temperatures and critical pressures of binary hydrocarbon systems have already been presented in the literature. It is possible to apply these existing methods to fixed gas-paraffin mixtures but due to their unusual critical behavior, values calculated deviate considerably from experimental values. For systems containing trace quantities of the fixed gases, these methods are acceptable; however, for systems containing more than 5 mol per cent of the fixed gases, these utterly fail to produce reasonable critical values. Consequently, in this study a method has been developed for handling such binary mixtures over the entire composition range. CARBON-DIOXIDE AND HYDROGEN-SULFIDE SYSTEMS The critical behavior and the vapor pressure behavior of mixtures of carbon dioxide and hydrogen sulfide with paraffinic hydrocarbons may be quite similar or quite dissimilar to that of paraffin-paraffin mixtures, depending on the volatilities of the components involved. The critical temperature and normal boiling point of carbon dioxide are very close to the corresponding values for ethane, while its critical pressure is considerably higher than that of ethane. SPEJ P. 197^


Sign in / Sign up

Export Citation Format

Share Document