An electrochemical aptasensor based on graphene doped chitosan nanocomposites for determination of Ochratoxin A

2019 ◽  
Vol 144 ◽  
pp. 102-109 ◽  
Author(s):  
Navpreet Kaur ◽  
Anu Bharti ◽  
Supriya Batra ◽  
Shilpa Rana ◽  
Shweta Rana ◽  
...  
2013 ◽  
Vol 25 (8) ◽  
pp. 1847-1854 ◽  
Author(s):  
Gennady Evtugyn ◽  
Anna Porfireva ◽  
Rusal Sitdikov ◽  
Vladimir Evtugyn ◽  
Ivan Stoikov ◽  
...  

2017 ◽  
Vol 35 (2) ◽  
pp. 185 ◽  
Author(s):  
Xiaoming GONG ◽  
Ronghui MA ◽  
Hongtao WANG ◽  
Liqiang GUO ◽  
Kai LI ◽  
...  

2021 ◽  
Vol 379 ◽  
pp. 138172
Author(s):  
Maham Liaqat ◽  
Sara Riaz ◽  
Mian Hasnain Nawaz ◽  
Mihaela Badea ◽  
Akhtar Hayat ◽  
...  

2021 ◽  
Vol 188 (5) ◽  
Author(s):  
Zhenfeng Lin ◽  
Xin Liu ◽  
Yangzi Li ◽  
Changxiang Li ◽  
Liu Yang ◽  
...  

Heliyon ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. e06663
Author(s):  
Mariel Cina ◽  
María del Valle Ponce ◽  
Luis Dante Martinez ◽  
Soledad Cerutti
Keyword(s):  

Toxins ◽  
2021 ◽  
Vol 13 (8) ◽  
pp. 547
Author(s):  
Kai Zhang

Two methods for measuring ochratoxin A in corn, oat, and grape juice were developed and compared. Flow injection (FI) and on-line liquid chromatography (LC) performances were evaluated separately, with both methods using a triple quadrupole tandem mass spectrometer (MS/MS) for quantitation. Samples were fortified with 13C uniformly labeled ochratoxin A as the internal standard (13C-IS) and prepared by dilution and filtration, followed by FI- and LC-MS/MS analysis. For the LC-MS/MS method, which had a 10 min run time/sample, recoveries of ochratoxin A fortified at 1, 5, 20, and 100 ppb in corn, oat, red grape juice, and white grape juice ranged from 100% to 117% with RSDs < 9%. The analysis time of the FI-MS/MS method was <60 s/sample, however, the method could not detect ochratoxin A at the lowest fortification concentration, 1 ppb, in all tested matrix sources. At 5, 20, and 100 ppb, recoveries by FI-MS/MS ranged from 79 to 117% with RSDs < 15%. The FI-MS/MS method also had ~5× higher solvent and matrix-dependent instrument detection limits (0.12–0.35 ppb) compared to the LC-MS/MS method (0.02–0.06 ppb). In the analysis of incurred corn and oat samples, both methods generated comparable results within ±20% of reference values, however, the FI-MS/MS method failed to determine ochratoxin A in two incurred wheat flour samples due to co-eluted interferences due to the lack of chromatographic separation.


Sign in / Sign up

Export Citation Format

Share Document