Ultra-fast gas chromatographic with flame ionization detector (UFGC-FID) and sonication methods for determination of total petroleum hydrocarbons fractions and BTEX in soil

2019 ◽  
Vol 150 ◽  
pp. 104163 ◽  
Author(s):  
Maurílio Gustavo Nespeca ◽  
Rodrigo Sequinel ◽  
José Eduardo de Oliveira
1966 ◽  
Vol 49 (4) ◽  
pp. 857-859
Author(s):  
C L Bramlett

Abstract Phenothiazine, promethazine.HCl, chlorpromazine. HCl, promazine.HCl, and levomepromazine. HCl were chromatographed satisfactorily on a column containing 5% Apiezon L coated on Anakrom ABS, 100/110 mesh, using a hydrogen-flame ionization detector. This gas chromatographic technique is rapid and more specific than existing official methods. The use of an internal standard to improve precision will be investigated.


1974 ◽  
Vol 20 (11) ◽  
pp. 1460-1462 ◽  
Author(s):  
Naresh C Jain ◽  
Thomas C Sneath ◽  
Robert D Budd

Abstract A simple, rapid procedure is described for measuring amphetamine and methamphetamine in urine by gas chromatography, with use of a flame ionization detector. This method is sensitive to subtherapeutic concentrations (0.1 µg/ml or less), and is especially useful in clinical situations where an accurate and quantitative result is needed in less than 30 min. With the method, amphetamine and methamphetamine can be determined as the free bases on a 10% Apiezon L-10% KOH column and as their trifluoroacetamide derivatives on a 3% OV-17 column. This dual analysis eliminates false positives and any interfering substances that may be present in the urine, and is thus a specific method for the two drugs.


1983 ◽  
Vol 66 (5) ◽  
pp. 1067-1073
Author(s):  
Sandra L Varner ◽  
Charles V Breder ◽  
Thomas Fazio

Abstract Migration studies were conducted to determine the quantity of styrene that migrates from polymers into fatty foods, specifically margarine. Azeotropic distillation was used to isolate styrene from the margarine. Headspace gas chromatography with a Chromosorb 104 column and a flame ionization detector was used for quantitation. The quantitation limit for the method was about 25 ppb (wt/wt) styrene in margarine. On the average, greater than 90% of the styrene was recovered. Several commercial margarines were examined. The method and results of the migration studies are presented. There was no detectable migration of styrene into margarine.


Sign in / Sign up

Export Citation Format

Share Document