Fiber optic particle plasmon resonance immunosensor for rapid and sensitive detection of methamphetamine based on competitive inhibition

2020 ◽  
Vol 157 ◽  
pp. 105026 ◽  
Author(s):  
Ting-Chou Chang ◽  
Chang-Yue Chiang ◽  
Min-Hsiu Lin ◽  
I-Kuang Chen ◽  
Lai-Kwan Chau ◽  
...  
2013 ◽  
Vol 85 (21) ◽  
pp. 10625-10625 ◽  
Author(s):  
Ting-Chou Chang ◽  
Chao-Ching Wu ◽  
Shau-Chun Wang ◽  
Lai-Kwan Chau ◽  
Wen-Hsin Hsieh

Talanta ◽  
2016 ◽  
Vol 146 ◽  
pp. 291-298 ◽  
Author(s):  
Chin-Wei Wu ◽  
Chang-Yue Chiang ◽  
Chien-Hsing Chen ◽  
Chung-Sheng Chiang ◽  
Chih-To Wang ◽  
...  

2011 ◽  
Vol 697 (1-2) ◽  
pp. 75-82 ◽  
Author(s):  
Wei-Ting Hsu ◽  
Wen-Hsin Hsieh ◽  
Shu-Fang Cheng ◽  
Chung-Ping Jen ◽  
Chao-Ching Wu ◽  
...  

2012 ◽  
Vol 85 (1) ◽  
pp. 245-250 ◽  
Author(s):  
Ting-Chou Chang ◽  
Chao-Ching Wu ◽  
Shau-Chun Wang ◽  
Lai-Kwan Chau ◽  
Wen-Hsin Hsieh

Sensors ◽  
2020 ◽  
Vol 20 (11) ◽  
pp. 3086
Author(s):  
Chang-Yue Chiang ◽  
Chien-Hsing Chen ◽  
Chien-Tsung Wang

A novel multi-microchannel biochip fiber-optic particle plasmon resonance (FOPPR) sensor system for the simultaneous detection of multiple samples. The system integrates a novel photoelectric system, a lock-in module, and an all-in-one platform incorporating optical design and mechanical design together to improve system stability and the sensitivity of the FOPPR sensor. The multi-microchannel FOPPR biochip has been developed by constructing a multi-microchannel flow-cell composed of plastic material to monitor and analyze five samples simultaneously. The sensor system requires only 30 μL of sample for detection in each microchannel. Moreover, the total size of the multi-microchannel FOPPR sensor chip is merely 40 mm × 30 mm × 4 mm; thus, it is very compact and cost-effective. The analysis was based on calibration curves obtained from real-time sensor response data after injection of sucrose solution, streptavidin and anti-dinitrophenyl (anti-DNP) antibody of known concentrations over the chips. The results show that the multi-microchannel FOPPR sensor system not only has good reproducibility (coefficient of variation (CV) < 10%), but also excellent refractive index resolution (6.23 ± 0.10 × 10−6 refractive index unit (RIU)). The detection limits are 2.92 ± 0.28 × 10−8 g/mL (0.53 ± 0.01 nM) and 7.48 ± 0.40 × 10−8 g/mL (0.34 ± 0.002 nM) for streptavidin and anti-DNP antibody, respectively.


2014 ◽  
Vol 51 ◽  
pp. 371-378 ◽  
Author(s):  
Hsing-Ying Lin ◽  
Chen-Han Huang ◽  
Sin-Hong Lu ◽  
I-Ting Kuo ◽  
Lai-Kwan Chau

Sign in / Sign up

Export Citation Format

Share Document