Dual-mode biosensor for femtomolar miRNA-155 detection by electrochemiluminescence and adsorptive stripping voltammetry

2021 ◽  
Vol 165 ◽  
pp. 106091
Author(s):  
Yanjie Zheng ◽  
Li Chen ◽  
Xinyang Yin ◽  
Fei Lin ◽  
Yichun Xu ◽  
...  
2021 ◽  
Author(s):  
Yuanzhe Wang ◽  
Archana Kaliyaraj Selva Kumar ◽  
Richard G. Compton

1985 ◽  
Vol 57 (1) ◽  
pp. 158-162 ◽  
Author(s):  
Joseph. Wang ◽  
Den Bai. Luo ◽  
Percio A. M. Farias ◽  
Jawad S. Mahmoud

2008 ◽  
Vol 4 (3) ◽  
pp. 242-249 ◽  
Author(s):  
Jiri Barek ◽  
Karolina Peckova ◽  
Vlastimil Vyskocil

2015 ◽  
Vol 49 (9) ◽  
pp. 1436-1451 ◽  
Author(s):  
Dan Zhu ◽  
Qiangqiang Li ◽  
Kevin C. Honeychurch ◽  
Martina Piano ◽  
Gang Chen

Environments ◽  
2018 ◽  
Vol 5 (11) ◽  
pp. 120 ◽  
Author(s):  
Charlton van der Horst ◽  
Bongiwe Silwana ◽  
Emmanuel Iwuoha ◽  
Vernon Somerset

The emission of toxic compounds by increasing anthropogenic activities affects human health and the environment. Heavy road traffic and mining activities are the major anthropogenic activities contributing to the presence of metals in the environment. The release of palladium (Pd), platinum (Pt), and rhodium (Rh) into the environment increases the levels of contamination in soils, road sediments, airborne particles, and plants. These Pd, Pt, and Rh in road dusts can be soluble and enter aquatic environment posing a risk to environment and human health. The aim of this study is to determine the levels of Pd, Pt, and Rh with spectroscopy and voltammetric methods. Potential interferences by other metal ions (Na(I), Fe(III), Ni(II), Co(II)) in voltammetric methods have also been investigated in this study. At all the sampling sites very low concentrations of Pd, Pt, and Rh were found at levels that range from 0.48 ± 0.05 to 5.44 ± 0.11 ng/g (dry weight (d.wt)) for Pd(II), with 17.28 ± 3.12 to 81.44 ± 3.07 pg/g (d.wt) for Pt(II), and 14.34 ± 3.08 to 53.35 ± 4.07 pg/g (d.wt) for Rh(III). The instrumental limit of detection for Pd, Pt, and Rh for Inductively Coupled Plasma Quadrupole-based Mass Spectrometry (ICP-QMS) analysis was found to be 3 × 10−6 µg/g, 3 × 10−6 µg/g and 1 × 10−6 µg/g, respectively. In the case of voltammetric analysis the instrumental limit of detection for Pd(II), Pt(II), and Rh(III) for differential pulse adsorptive stripping voltammetry was found to be 7 × 10−8 µg/g, 6 × 10−8 µg/g, and 2 × 10−7 µg/g, respectively. For the sensor application, good precision was obtained due to consistently reproduced the measurements with a reproducibility of 6.31% for Pt(II), 7.58% for Pd(II), and 5.37% for Rh(III) (n = 10). The reproducibility for ICP-QMS analysis were 1.58% for Pd(II), 1.12% for Pt(II), and 1.37% for Rh(III) (n = 5). In the case of repeatability for differential pulse adsorptive stripping voltammetry (DPAdSV) and ICP-QMS, good standard deviations of 0.01 for Pd(II); 0.02 for Pt(II), 0.009 for Rh(III) and 0.011 for Pd, 0.019 for Pt and 0.013 for Rh, respectively.


Sign in / Sign up

Export Citation Format

Share Document