adsorptive stripping voltammetry
Recently Published Documents


TOTAL DOCUMENTS

602
(FIVE YEARS 39)

H-INDEX

40
(FIVE YEARS 4)

Chemosensors ◽  
2022 ◽  
Vol 10 (1) ◽  
pp. 36
Author(s):  
Agnieszka Królicka ◽  
Jerzy Zarębski ◽  
Andrzej Bobrowski

In the review, voltammetric analytical procedures that employ vanadium(IV) and aminopolycarboxylic complexes of V(IV) are presented and discussed. The focus of the paper is on the mechanism of vanadium-catalyzed reactions responsible for the amplification of the analytical signal of Ge(IV). The analytical efficacy of different catalytic systems is compared, and the optimal parameters of the respective procedures are reported.


2021 ◽  
Vol 56 (9) ◽  
pp. 828-837
Author(s):  
Priscila A. Liberato ◽  
Leonardo L. Okumura ◽  
Astréa F. S. Silva ◽  
Alexandre Gurgel ◽  
Herbert Aleixo ◽  
...  

Materials ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4231
Author(s):  
Jędrzej Kozak ◽  
Katarzyna Tyszczuk-Rotko ◽  
Magdalena Wójciak ◽  
Ireneusz Sowa ◽  
Marek Rotko

In this paper, a screen-printed boron-doped electrode (aSPBDDE) was subjected to electrochemical activation by cyclic voltammetry (CV) in 0.1 M NaOH and the response to rifampicin (RIF) oxidation was used as a testing probe. Changes in surface morphology and electrochemical behaviour of RIF before and after the electrochemical activation of SPBDDE were studied by scanning electron microscopy (SEM), CV and electrochemical impedance spectroscopy (EIS). The increase in number and size of pores in the modifier layer and reduction of charge transfer residence were likely responsible for electrochemical improvement of the analytical signal from RIF at the SPBDDE. Quantitative analysis of RIF by using differential pulse adsorptive stripping voltammetry in 0.1 mol L−1 solution of PBS of pH 3.0 ± 0.1 at the aSPBDDE was carried out. Using optimized conditions (Eacc of −0.45 V, tacc of 120 s, ΔEA of 150 mV, ν of 100 mV s−1 and tm of 5 ms), the RIF peak current increased linearly with the concentration in the four ranges: 0.002–0.02, 0.02–0.2, 0.2–2.0, and 2.0–20.0 nM. The limits of detection and quantification were calculated at 0.22 and 0.73 pM. The aSPBDDE showed satisfactory repeatability, reproducibility, and selectivity towards potential interferences. The applicability of the aSPBDDE for control analysis of RIF was demonstrated using river water samples and certified reference material of bovine urine.


2021 ◽  
Author(s):  
Yuanzhe Wang ◽  
Archana Kaliyaraj Selva Kumar ◽  
Richard G. Compton

2021 ◽  
Vol 165 ◽  
pp. 106091
Author(s):  
Yanjie Zheng ◽  
Li Chen ◽  
Xinyang Yin ◽  
Fei Lin ◽  
Yichun Xu ◽  
...  

Chemosensors ◽  
2021 ◽  
Vol 9 (5) ◽  
pp. 94
Author(s):  
Víctor Padilla ◽  
Núria Serrano ◽  
José Manuel Díaz-Cruz

A commercial and disposable screen-printed carbon electrode (SPCE) has been proposed for a fast, simple and low-cost determination of Ni(II) at very low concentration levels by differential pulse adsorptive stripping voltammetry (DPAdSV) in the presence of dimethylglyoxime (DMG) as complexing agent. In contrast with previously proposed methods, the Ni(II)-DMG complex adsorbs directly on the screen-printed carbon surface, with no need of mercury, bismuth or antimony coatings. Well-defined stripping peaks and a linear dependence of the peak area on the concentration of Ni(II) was achieved in the range from 1.7 to 150 µg L−1, with a limit of detection of 0.5 µg L−1 using a deposition time of 120 s. An excellent reproducibility and repeatability with 0.3% (n = 3) and 1.5% (n = 15) relative standard deviation, respectively, were obtained. In addition, the suitability of the SPCE as sensing unit has been successfully assessed in a wastewater certificated reference material with remarkable trueness and very good reproducibility.


Sign in / Sign up

Export Citation Format

Share Document