Hybrid NiO nanostructured/sulfanilamide polymeric film for studying possible pharmacokinetic interaction between avanafil and nimodipine in real human serum by their simultaneous determination using square-wave voltammetry

2021 ◽  
pp. 106895
Author(s):  
Al-Montaser Bellah H. Ali ◽  
Fatma A.M. Abdel-aal ◽  
Azza H. Rageh ◽  
Abdel-Maaboud I. Mohamed
2016 ◽  
Vol 129 ◽  
pp. 205-212 ◽  
Author(s):  
Adrian Marcelo Granero ◽  
Gastón Darío Pierini ◽  
Sebastián Noel Robledo ◽  
María Susana Di Nezio ◽  
Héctor Fernández ◽  
...  

Author(s):  
İsmail Murat Palabıyık ◽  
Aysegul Dogan ◽  
İncilay Süslü

Background: Hypertension is one of the most important health problems in the world and irbesartan and amlodipine are used in combination in various dosages for the treatment of high blood pressure. Objective: The aim of this study is to develop a fast, easy, sensitive, accurate, and precise square-wave voltammetry method for simultaneous determination of irbesartan and amlodipine besylate from pharmaceutical formulations at a hanging mercury drop electrode. Methods: In the applied method, since both active substances gave a peak at different potentials, no interference occurred between them. In optimization studies Britton-Robinson buffer of pH 8.0 was chosen, in which the most appropriate peak shape and maximum peak current were observed. At the same time, as a result of instrumental parameter optimization to obtain reproducible results, 6 mV for scan increment, 30 mV for pulse amplitude, and 50 Hz for frequency were found suitable. Results: As a result of the calibration studies of the optimized method, linear working ranges were determined as 1.00-13.08 µg mL-1 for irbesartan and 5.83-16.51 µg mL-1 for amlodipine besylate. Limit of detection and limit of quantitation values were respectively calculated as 0.63 and 1.00 µg mL-1 for irbesartan and 0.50 and 1.98 µg mL-1 for amlodipine besylate. The results of precision values (RSD) ranged from 0.67% to 2.31% for irbesartan and 0.65% to 1.49% for amlodipine besylate. Accuracy values were calculated as -0.15% to 1.63% for irbesartan and -0.07% to 3.78% for amlodipine besylate. The results obtained from the recovery studies ranged from 101.05% to 102.78% and from 98.88% to 102.20% for amlodipine besylate and irbesartan, respectively. Conclusion: After the validation studies of the developed method were carried out, it was successfully applied to pharmaceutical formulations containing these active substances.


2020 ◽  
Vol 34 (2) ◽  
pp. 227-236
Author(s):  
E. A. M. Al-Jawadi ◽  
M. I. Majeed

A tool has been developed in this study to estimate one of the Irinotecan (INR) cancer drugs used in the treatment of lung cancer by using square wave voltammetry (SWV) techniques, on surface of electrode graphite (GrE) and through of study the optimal condition that enhance the work of this electrode. The measurements are also enhanced by the electro-polymerization process of the neutral red pigment (NR) and using when presence of titanium nanoparticles (TiO2NPs) to be greatly enhanced by measuring of LOD, LOQ and applied to human serum samples.                     KEY WORDS: Irinotecan, Lung cancer, Square wave voltammetry, Titanium nanoparticles, Serum   Bull. Chem. Soc. Ethiop. 2020, 34(2), 227-236 DOI: https://dx.doi.org/10.4314/bcse.v34i2.2


Sign in / Sign up

Export Citation Format

Share Document