Evaluation and comparison of a CdTe based photon counting detector with an energy integrating detector for X-ray phase sensitive imaging of breast cancer

2021 ◽  
pp. 1-13
Author(s):  
Muhammad U. Ghani ◽  
Farid H. Omoumi ◽  
Xizeng Wu ◽  
Laurie L. Fajardo ◽  
Bin Zheng ◽  
...  

PURPOSE: To compare imaging performance of a cadmium telluride (CdTe) based photon counting detector (PCD) with a CMOS based energy integrating detector (EID) for potential phase sensitive imaging of breast cancer. METHODS: A high energy inline phase sensitive imaging prototype consisting of a microfocus X-ray source with geometric magnification of 2 was employed. The pixel pitch of the PCD was 55μm, while 50μm for EID. The spatial resolution was quantitatively and qualitatively assessed through modulation transfer function (MTF) and bar pattern images. The edge enhancement visibility was assessed by measuring edge enhancement index (EEI) using the acrylic edge acquired images. A contrast detail (CD) phantom was utilized to compare detectability of simulated tumors, while an American College of Radiology (ACR) accredited phantom for mammography was used to compare detection of simulated calcification clusters. A custom-built phantom was employed to compare detection of fibrous structures. The PCD images were acquired at equal, and 30% less mean glandular dose (MGD) levels as of EID images. Observer studies along with contrast to noise ratio (CNR) and signal to noise ratio (SNR) analyses were performed for comparison of two detection systems. RESULTS: MTF curves and bar pattern images revealed an improvement of about 40% in the cutoff resolution with the PCD. The excellent spatial resolution offered by PCD system complemented superior detection of the diffraction fringes at boundaries of the acrylic edge and resulted in an EEI value of 3.64 as compared to 1.44 produced with EID image. At MGD levels (standard dose), observer studies along with CNR and SNR analyses revealed a substantial improvement of PCD acquired images in detection of simulated tumors, calcification clusters, and fibrous structures. At 30% less MGD, PCD images preserved image quality to yield equivalent (slightly better) detection as compared to the standard dose EID images. CONCLUSION: CdTe-based PCDs are technically feasible to image breast abnormalities (low/high contrast structures) at low radiation dose levels using the high energy inline phase sensitive imaging technique.

2021 ◽  
Author(s):  
Muhammad U. Ghani ◽  
Xizeng Wu ◽  
Laurie L. Fajardo ◽  
Zhengxue Jing ◽  
Molly D. Wong ◽  
...  

2004 ◽  
Vol 37 (6) ◽  
pp. 967-976 ◽  
Author(s):  
Andrew C. Jupe ◽  
Stuart R. Stock ◽  
Peter L. Lee ◽  
Nikhila N. Naik ◽  
Kimberly E. Kurtis ◽  
...  

Spatially resolved energy dispersive X-ray diffraction, using high-energy synchrotron radiation (∼35–80 keV), was used nondestructively to obtain phase composition profiles along the radii of cylindrical cement paste samples to characterize the progress of the chemical changes associated with sulfate attack on the cement. Phase distributions were acquired to depths of ∼4 mm below the specimen surface with sufficient spatial resolution to discern features less than 200 µm thick. The experimental and data analysis methods employed to obtain quantitative composition profiles are described. The spatial resolution that could be achieved is illustrated using data obtained from copper cylinders with a thin zinc coating. The measurements demonstrate that this approach is useful for nondestructively visualizing the sometimes complex transformations that take place during sulfate attack on cement-based materials. These transformations can be spatially related to microstructure as seen by computed microtomography.


2011 ◽  
Vol 59 (5) ◽  
pp. 3114-3119 ◽  
Author(s):  
Yu-Na Choi ◽  
Seung-Wan Lee ◽  
Hyo-Min Cho ◽  
Hyun-Ju Ryu ◽  
Young-Jin Lee ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document