Characterization and calibration of a triple-GEM detector for medical dosimetry

Author(s):  
Andrea Velásquez Moros ◽  
Héctor Fabio Castro Serrato
2007 ◽  
Vol 1039 ◽  
Author(s):  
Philippe Bergonzo ◽  
Hassen Hamrita ◽  
Dominique Tromson ◽  
Caroline Descamps ◽  
Christine Mer ◽  
...  

AbstractCVD diamond combines attractive properties for the fabrication of detection devices operating in specific environments. One problem that remains critical for device stability is the presence of defect levels that alter the detection performances, and the detection characteristics often appear as they are very depending on time, temperature, and history of the preceding irradiations.One issue we have proposed is to adapt one technique that is commonly used for time of flight spectroscopy in order to maintain a uniform electric field in the probed device, and based on the synchronisation of the device bias with the period of the excitation source. This can be applied to several types of detection applications, as long as we can rely on periodical triggering in order to synchronise the device polarisation. We apply it here to a LINAC electron accelerator used for photon pulse generation at the frequency of 25Hz. The result is a remarkable improvement of the performance of a polycrystalline diamond detector that exhibits a particularly defective response when used in the steady state excitation, to reach that of a perfectly stable and reproducible device response in the pulsed mode. We claim this method to be applicable to several types of excitations and particularly to present a high interest for monitoring accelerator sources, e.g. for medical dosimetry applications.


Author(s):  
A. Pezzotta ◽  
G. Corradi ◽  
G. Croci ◽  
M. De Matteis ◽  
F. Murtas ◽  
...  
Keyword(s):  

2013 ◽  
Vol 8 (12) ◽  
pp. C12020-C12020 ◽  
Author(s):  
T Fujiwara ◽  
S Tanaka ◽  
Y Mitsuya ◽  
H Takahashi ◽  
K Tagi ◽  
...  

2017 ◽  
Vol 138 ◽  
pp. 11004
Author(s):  
Dmitriy Baranov ◽  
Oleg Rogachevsky
Keyword(s):  

2011 ◽  
Author(s):  
Seongtae Park ◽  
Edwin Baldelomar ◽  
Kwangjune Park ◽  
Mark Sosebee ◽  
Andy White ◽  
...  

2015 ◽  
Vol 10 (10) ◽  
pp. P10013-P10013 ◽  
Author(s):  
T. Czarski ◽  
M. Chernyshova ◽  
K.T. Pozniak ◽  
G. Kasprowicz ◽  
W. Zabolotny ◽  
...  

Author(s):  
Rajendra Nath Patra ◽  
Rama Narayan Singaraju ◽  
Saikat Biswas ◽  
Yogendra P. Viyogi ◽  
Tapan K. Nayak
Keyword(s):  

1994 ◽  
pp. 595-598
Author(s):  
J. V. Minervini ◽  
P. G. Marston ◽  
B. A. Smith ◽  
R. J. Camille ◽  
Z. S. Piek ◽  
...  
Keyword(s):  

2021 ◽  
Vol 16 (11) ◽  
pp. P11014
Author(s):  
M. Abbas ◽  
M. Abbrescia ◽  
H. Abdalla ◽  
A. Abdelalim ◽  
S. AbuZeid ◽  
...  

Abstract After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high η region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high pT muons in proton-proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.


2021 ◽  
Author(s):  
◽  
Joseph Schuyt

<p>The luminescence of crystalline compounds can be used to monitor many physical phenomena, including doses of ionising radiation. Optically stimulated luminescence (OSL), thermoluminescence (TL), and radiophotoluminescence (RPL) have been successfully employed in dosimetry. However, few materials possess both the structural and luminescence properties required for medical dosimetry. This thesis aimed to investigate the luminescence features of the class of compounds known as fluoroperovskites. Emphasis was placed on studying the effects of irradiation on the luminescence properties, such that the compounds could be evaluated regarding potential applications in clinical dosimetry. Samples were primarily characterised using photoluminescence (PL), radioluminescence (RL), OSL, RPL, TL, and transmittance spectroscopy.  OSL was observed in the majority of samples due to the existence of electron trapping F-type centres. F-centre/Mn complexes were observed in all AMgF3:Mn compounds after irradiation and the energy levels of the complexes in each compound were experimentally determined. The most promising potential dosimeter host material was the near tissue-equivalent NaMgF3. When doped with Mn2+, the compound exhibited RPL via the formation of F-centre/Mn complexes and OSL via several trapping centres. The RPL could be probed independently to the OSL such that the compound could function as a hybrid OSL/RPL dosimeter. In the NaMgF3:Ln compounds, RPL occurred via the radiation-induced reduction Ln3+ → Ln2+ for Ln = Sm, Dy, and Yb. The reduction Sm3+ → Sm2+ was highly stable and could be non-destructively probed independently to the OSL. The Sm doped compound also exhibited radiation-induced conductivity that could be coupled with the RL, such that the compound could function as a real-time hybrid optical/electrical dosimeter. Charge kinetics, thermal quenching, and binding energy models were developed and applied to the compounds.   Finally, a two-dimensional readout system was designed and constructed. The capabilities of the system were evaluated using the OSL of NaMgF3:Eu and NaMgF3:Mn. Sensitivities to doses from < 10 mGy to > 1 Gy were obtained along with sub-millimetre spatial resolutions.</p>


Sign in / Sign up

Export Citation Format

Share Document