Functional Assessment of Two Different Accommodative Intraocular Lenses Compared with a Monofocal Intraocular Lens

Ophthalmology ◽  
2007 ◽  
Vol 114 (11) ◽  
pp. 2038-2043 ◽  
Author(s):  
Giorgio Marchini ◽  
Paolo Mora ◽  
Emilio Pedrotti ◽  
Francesca Manzotti ◽  
Raffaella Aldigeri ◽  
...  

Drops of lens nucleus/cortex particles into the vitreous cavity or dislocations of intraocular lenses (IOLs) are one of the serious complications of cataract surgery with an increasing relative frequency with the increase in the number of cataract surgeries. In addition, spontaneous and traumatic dislocations are other common case groups that should be treated. In this article, the vitreous dislocations of nucleus/cortex residues or IOL dislocations are discussed with different vitreoretinal surgical techniques.


2012 ◽  
Vol 46 (2) ◽  
pp. 95-97
Author(s):  
Nishant Gupta ◽  
Jagat Ram ◽  
Manish Chaudhary ◽  
Jaspreet Singh Sukhija ◽  
Jaidrath Kumar

ABSTRACT Objective To report opacification of hydrophilic acrylic and silicone foldable intraocular lenses (IOL). Designs Case series. Participants Five patients with IOL opacification. Results We report five eyes of five patients with late opacification of the intraocular lens (IOL). Three patients had hydrophilic acrylic (SC60B-OUV-MDR, Inc), two had silicone IOL (Allergan SI30NB). Two out of the three patients with opacified hydrophilic acrylic IOLs had diabetes mellitus. Three eyes with opacified acrylic IOL underwent IOL exchange with hydrophobic acrylic IOL. Two silicone IOL patients had no visually significant opacification and were managed conservatively. Conclusion IOL optic opacification in hydrophilic acrylic and silicone IOL may be due to defective material, manufacturing process, storage. How to cite this article Ram J, Gupta N, Chaudhary M, Sukhija JS, Gupta A, Kumar J. Late Opacification of Foldable Intraocular Lenses. J Postgrad Med Edu Res 2012;46(2):95-97.


2009 ◽  
Vol 35 (10) ◽  
pp. 1706-1710 ◽  
Author(s):  
Anat Galor ◽  
Maricely Gonzalez ◽  
David Goldman ◽  
Terrence P. OʼBrien

2018 ◽  
Vol 29 (4) ◽  
pp. 417-425 ◽  
Author(s):  
Francisco Poyales ◽  
Nuria Garzón ◽  
Daniel Pizarro ◽  
Santiago Cobreces ◽  
Adolfo Hernández

Purpose: To compare rotational stability, centration and visual outcomes provided by three trifocal lens models that have the same optical zone design but different material, composition, and/or toricity. Methods: The study included 78 patients with symmetric bilateral intraocular lens implantation. The lenses under evaluation were trifocal intraocular lenses made of hydrophilic acrylic material: a spherical lens 26% hydrophilic acrylic (POD FineVision), a similar lens but having a toric design (POD Toric FineVision), and a trifocal lens 25% hydrophilic acrylic material (FineVision/MicroF). Moreover, the lenses share the same optical zone design. The lenses’ rotational stability and centration were measured by means of the PIOLET software, which relies on recording and image processing techniques to determine lens rotation and centration based on slit-lamp images. We also assessed patients’ visual quality by means of 25, 40, and 80 cm VA tests. Results: The best centration results were achieved with the POD Toric FineVision model, although the differences were not statistically significant. As for lens rotation, it was below 5° in all cases under study. Regarding VA, all subjects attained at least 0.3 logMAR for far distance uncorrected VA, at 80 cm VA was about 0.2 logMAR, at 40 cm it was above 0.15 logMAR, and at 25 cm it was about 0.3 logMAR for both lens types. Conclusion: All three intraocular lens models yield excellent visual results at far, near as well as intermediate distances. The POD FineVision and POD Toric FineVision models, with double C-loop design, yielded the best results centration-wise and rotation-wise. Differences had no clinical relevance.


Eye ◽  
2018 ◽  
Vol 33 (3) ◽  
pp. 404-410 ◽  
Author(s):  
Giacomo Savini ◽  
Nicole Balducci ◽  
Claudio Carbonara ◽  
Scipione Rossi ◽  
Manuel Altieri ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document