Hemoglobin sensor based on external gold-coated photonic crystal fiber

2022 ◽  
Vol 149 ◽  
pp. 107817
Author(s):  
Monika Kiroriwal ◽  
Poonam Singal ◽  
Mohit Sharma ◽  
Abhinandan Singal
2018 ◽  
Vol 1 (1) ◽  
pp. 2-19
Author(s):  
Mahmood Sh. Majeed ◽  
Raid W. Daoud

A new method proposed in this paper to compute the fitness in Genetic Algorithms (GAs). In this new method the number of regions, which assigned for the population, divides the time. The fitness computation here differ from the previous methods, by compute it for each portion of the population as first pass, then the second pass begin to compute the fitness for population that lye in the portion which have bigger fitness value. The crossover and mutation and other GAs operator will do its work only for biggest fitness portion of the population. In this method, we can get a suitable and accurate group of proper solution for indexed profile of the photonic crystal fiber (PCF).


2009 ◽  
Vol 129 (4) ◽  
pp. 601-607
Author(s):  
Shubi F. Kaijage ◽  
Yoshinori Namihira ◽  
Nguyen H. Hai ◽  
Feroza Begum ◽  
S. M. Abdur Razzak ◽  
...  

Optik ◽  
2020 ◽  
Vol 218 ◽  
pp. 164997 ◽  
Author(s):  
Anurag Upadhyay ◽  
Shivam Singh ◽  
Y.K. Prajapati ◽  
Rajeev Tripathi

Optik ◽  
2020 ◽  
Vol 224 ◽  
pp. 165522
Author(s):  
Pibin Bing ◽  
Guifang Wu ◽  
Jialei Sui ◽  
Hongtao Zhang ◽  
Lian Tan ◽  
...  

IEEE Access ◽  
2021 ◽  
Vol 9 ◽  
pp. 2924-2933
Author(s):  
M. Hussayeen Khan Anik ◽  
M. Ifaz Ahmad Isti ◽  
S. M. Riazul Islam ◽  
Sakib Mahmud ◽  
Hriteshwar Talukder ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (5) ◽  
pp. 1799
Author(s):  
Tianyu Yang ◽  
Liang Zhang ◽  
Yunjie Shi ◽  
Shidi Liu ◽  
Yuming Dong

A photonic crystal fiber (PCF) with high relative sensitivity was designed and investigated for the detection of chemical analytes in the terahertz (THz) regime. To ease the complexity, an extremely simple cladding employing four struts is adopted, which forms a rectangular shaped core area for filling with analytes. Results of enormous simulations indicate that a minimum 87.8% relative chemical sensitivity with low confinement and effective material absorption losses can be obtained for any kind of analyte, e.g., HCN (1.26), water (1.33), ethanol (1.35), KCN (1.41), or cocaine (1.50), whose refractive index falls in the range of 1.2 to 1.5. Besides, the PCF can also achieve high birefringence (∼0.01), low and flat dispersion, a large effective modal area, and a large numerical aperture within the investigated frequency range from 0.5 to 1.5 THz. We believe that the proposed PCF can be applied to chemical sensing of liquid and THz systems requiring wide-band polarization-maintaining transmission and low attenuation.


Sign in / Sign up

Export Citation Format

Share Document