scholarly journals Neonatal percutaneous central venous catheters: Equations for the inserted length and locations of the insertion sites

2019 ◽  
Vol 60 (3) ◽  
pp. 235-236
Author(s):  
Ming-Chou Chiang
PEDIATRICS ◽  
1986 ◽  
Vol 78 (2) ◽  
pp. 245-250 ◽  
Author(s):  
Manuel Durand ◽  
Rangasamy Ramanathan ◽  
Bruce Martinelli ◽  
Milagros Tolentino

With improved neonatal survival, especially of very low birth weight infants, our efforts should be directed toward reduction of morbidity. Sick preterm infants require total parenteral nutrition for prolonged periods of time due to extreme prematurity and feeding intolerance. However, the use of surgically placed Broviac catheters has been associated with a high complication rate. A prospective study of 53 percutaneous central venous Silastic catheterizations for administration of total parenteral nutrition was performed in 45 newborn infants. At the time of catheter insertion, 37 babies weighed less than 1,500 g and 19 weighed less than 1,000 g. Percutaneous central venous catheters were placed successfully the first time in 50 of 55 attempts. In three babies, insertion was successful on second attempt. The catheters remained in place for 25.4 ± 16.7 days ([mean ± SD] range two to 80 days). In babies weighing less than 1,000 g, the catheters remained in place for a longer period of time (34.0 ± 18.0; range 12 to 80 days). Sixty-six percent of the catheters were removed electively. There were four cases of bacteremia (7.5%), and the overall incidence of mechanical complications was 26.4%. We conclude that percutaneous central venous catheters can be used safely and effectively in newborn infants for prolonged administration of total parenteral nutrition, especially in neonates weighing less than 1,000 g.


2004 ◽  
Vol 9 (2) ◽  
pp. 80-85 ◽  
Author(s):  
Phllip Lum

Abstract Purpose: To validate the formula-based central venous catheter (CVC) length measurement “tailored” to individual's height and access site for predicting optimum SVC tip position. Method: A prospective study of 3 percutaneous insertion sites (PICC, SCC and JC). Formula-based “LUM'S CVC MEASUREMENT GUIDE” was used to determine the catheter length. Results: Overall, 97% (373) of the total 382 insertions were successfully placed with CVC tip in the distal SVC (SVC between carina and atrio-cava junction) location. Conclusion: The “tailored fit” formula to individual patient height is a reliable tool to predict CVC length. Appropriate catheter length can greatly reduce the guesswork and possibility of complications related to tip malposition.


Sign in / Sign up

Export Citation Format

Share Document